Thomas & Betts RZ405 Dimensions inches + or 1/8, Dimensions mm +or, Air Opening Dimensions

Page 3

6. Dimensions

Figure 1 - Dimensions of Model CAUA

Top View

A

C Plenum Opening

D

Plenum

1” (25mm)

Right

Side 13-1/4”

View (337mm)

Alternate

Gas

Connection

3-5/8” (92mm)

Opening

B

Combustion Air Cutout

Venter Outlet

150, 200 - 5” (127mm);

150, 200, 250 -

250, 300, 350, 400 - 6” (152mm)

5” (127mm);

300, 350, 400 -

 

 

6” (152mm)

E F

 

G

2-3/8” (60mm)

 

H

Electrical (supply voltage)

Gas

4-1/8

6-3/8

(162mm)

(105mm)

 

Corner indicators for

16” cutting inlet air opening (406mm)

2-1/8” (54mm)

K

1-1/2” (38mm)

 

24-3/8”

(619mm)

Control Door

46-1/2”

(1181mm)

22-1/4”

(565mm)

Blower Door

1/2” (13mm)

Rear

View

Corner indicators for cutting

16” inlet air opening (406mm)

2-1/8” (54mm)

J

2-1/2” (64mm)

 

Front View

Control Side of Hater

NOTE: Composite drawings are

Bottom

not proportional for all sizes.

View

Dimensions (inches + or - 1/8")

Size

A

B

C

D

E

F

G

H

J

K

M

N

P

150

38

34-3/4

36

21

7-1/4

3-3/4

12-1/2

24

33

31

19

34

4-5/8

200

38

34-3/4

36

21

7-1/4

3-3/4

12-1/2

24

33

31

19

34

4-5/8

250

50

34-3/4

48

21

7-1/4

4-3/8

12-3/4

27-1/4

45

31

16

46

4-3/4

300

50

34-3/4

48

21

7-1/4

4-3/8

12-3/4

27-1/4

45

31

16

46

4-3/4

350

50

49-3/4

48

34

7

4-3/8

14-1/8

26-3/4

45

44

32

46

4-7/8

400

50

49-3/4

48

34

7

4-3/8

14-1/8

26-3/4

45

44

32

46

4-7/8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions (mm +or- 3)

 

 

 

 

 

 

 

 

Size

A

B

C

D

E

F

G

H

J

K

M

N

P

150

965

883

914

533

184

95

318

610

838

787

483

864

117

200

965

883

914

533

184

95

318

610

838

787

483

864

117

250

1270

883

1219

533

184

111

324

692

1143

787

406

1168

121

300

1270

883

1219

533

184

111

324

692

1143

787

406

1168

121

350

1270

1238

1219

864

178

111

359

679

1143

1118

813

1168

124

400

1270

1238

1219

864

178

111

359

679

1143

1118

813

1168

124

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Corner indicators for cutting inlet air opening.

M

BOTTOM VIEW

 

P

N

2”

 

(51mm)

Air Opening Dimensions

Supply Air (Discharge with duct flange)

C x D

Inlet Air Opening (location selected by installer)

Right Side of Heater

K x 16" (406mm)

Left Side* of Heater

K x 16" (406mm)

Rear of Heater

J x 16" (406mm)

Bottom of Heater

M x N

*Right side is illustrated; corner indicators for open- ing are the same on the left side.

Mfg No. 164771, Page 3

Image 3
Contents Model Caua Table of ContentsMounting the Heater Installation CodesWarranty Clearances General ContdAir Opening Dimensions DimensionsDimensions inches + or 1/8 Dimensions mm +orIndus Trial Decide which Venting System to InstallVenting and Combustion Air CommercialCombustion Air Inlet Venter OutletConcentric Adapter Clearance Venting and Combustion Air contdJoints SupportWall Flash or caulkInlet air pipe On the outsideInstallation Instructions for Option CC2 2b Install the rubber sealSide View Terminal 559mm minimum SnowClearance ExhaustVent System Support Vent Pipe and JointsVenter Flue Outlet Vent Pipe Diameter and LengthCondensation Vent Terminal Pipe and Vent CapHorizontal Vent Terminal Clearances Duct Connections and Ductwork Cut edges of the metal will be sharpSize 150 250 350 36 914mm 48 1219mm 21 533mm 34 864mm Supply Piping Manifold or Orifice Pressure SettingsGas Piping and Pressures Sizing a Gas Supply LineElectrical Supply and Connections Manifold Pressure Settings contdGas Piping and Pressures contd Burner Condensate DrainBelt Drive Combustion Air Proving SwitchBlower Motor and Drive Direct DriveIgnition System Adjusting Blower SpeedBlower Motor and Drive contd Gas ValveTypical Wiring Diagrams Typical Wiring Diagrams contd Electrical Connections Low Voltage Wiring field-suppliedOptional Cased Cooling Coil, Model ACUA, ACUB, or Acuc Burner Condensate DrainMixing Cabinet Outside and Return Air Optional Outside Air Return Air Mixing Box Discharge Plenum Sizes400 only Inlet Base Sizes 350 and 400 only250 Check/Test/Start-Up Check Installation & Start-UpCheck the installation prior to start-up Start-UpTo Turn OFF GAS to the Appliance Check installation after start-upManufacturer of HEATING, COOLING, and Ventilating Systems