Samsung AP50Q0CNAFR, AP55Q2DNUMG AP50Q0C/AP50Q0D/AP55Q2C/AP55Q2D Series, AP55Q0C/AP55Q0D Series

Page 23

AP50Q0C/AP50Q0D/AP55Q2C/AP55Q2D Series

When connecting 3Phase 4wires 380V AC

1. Remove the cover of electric box on side panel of the outdoor unit.

2.

 

 

AP50Q0C Series

Connect the electric input wires (R,S,T,N) to each terminal (R,S,T,N) of the electric box on

 

AP50Q0D Series

the outdoor unit respectively. (Input wires are purchased by the user separately.)

 

 

 

 

AP55Q2C Series

Connect the electric input wires (R,S,T,N) to each terminal (L1,L2,L3,N) of the electric box

 

AP55Q2D Series

on the outdoor unit respectively. (Input wires are purchased by the user separately.)

3. Connect the electric wires to each terminal on the indoor and outdoor unit respectively.

AP50Q0C/AP50Q0D Series

AP55Q2C/AP55Q2D Series

OUTDOOR SIDE

 

OUTDOOR SIDE

Knife switch or

 

 

 

Power terminals on the outdoor unit

Power terminals on the outdoor unit automatic

 

 

 

circuit breaker

 

Knife switch or

 

 

 

automatic

 

 

 

circuit breaker

 

 

Brown Black

 

Blue Brown Black

 

Blue

 

 

 

Indoor/outdoor unit

 

Indoor/outdoor unit

Electric input wires

connecting wire

Electric input wires

connecting wire

AP55Q0C/AP55Q0D Series

When connecting 3Phase 3wires 220V AC

1.Remove the cover of electric box on side panel of the outdoor unit.

2.Connect the electric input wires (R,S,T) to each terminal (L1,L2,L3) of the electric box on the outdoor unit respectively. (Input wires are purchased by the user separately.)

3.Connect the electric wires to each terminal on the indoor and outdoor unit respectively.

OUTDOOR SIDE

Power terminals on the outdoor unit

Blue

Brown

Black

 

Knife switch or automatic circuit breaker

Indoor/outdoor unit

Electric input wires

connecting wire

 

E-23

Image 23
Contents Air Conditioner Safety Precautions Contents Indoor Unit View of the UnitInserting the Remote Control Batteries Remote Control-ButtonsFor Illustrations are Operating PreparationCooling Your Room Selecting the Automatic Operating Mode Changing the Room Temperature Quickly Cooling Distant Place Removing Excess Humidity Airing Your Room Selecting E. Saver Mode Cooling Upwards Adjusting the Air Flow Direction VerticallyAdjusting the Air Flow Direction Horizontally WhenSetting the Off Timer To Cancel the Off TimerTopic Recommendation Other FunctionOperating Recommendations If the air conditioner is used at Then Temperature and Humidity RangesCleaning Your Air Conditioner Indoor TemperatureProblem Explanation/Solution Solving Common ProblemsPower Supply Technical SpecificationsCover hole Screw Accessory Parts ListPart Name Cable tie Putty Pipe band PipingOutdoor Unit Selection of Installation PlaceIndoor Unit Electrical Work AP55Q0C/AP55Q0D Series When connecting 3Phase 4wires 380V ACWhen connecting 3Phase 3wires 220V AC AP50Q0C/AP50Q0D/AP55Q2C/AP55Q2D SeriesInstallation Procedures Tightening of Connection Parts Connection of Refrigerant PipingFlare Processing Pipe BendingDrain Hose Connecting the PipeDrilling a Hole in the Wall Air Purge Refrigerant Charging Check Check and Test OperationTest Operation Packing and Unpacking Guide Outdoor unit Wire tube power cable Connection sleeve How to connect your extended power cablesQuestions or COMMENTS?
Related manuals
Manual 24 pages 39.32 Kb Manual 34 pages 39.63 Kb

AP50Q0CNAFR, AP55Q2DNUMG specifications

The Samsung AP55Q2DNUMG and AP50Q0CNAFR are two advanced air conditioning units known for their innovative technology and user-friendly features. These models are designed to provide efficient cooling and heating solutions for residential and commercial spaces.

The AP55Q2DNUMG is equipped with a powerful inverter compressor, which enhances energy efficiency by adjusting the motor speed to maintain the desired temperature without frequent on-off cycles. This not only contributes to lower energy bills but also reduces wear and tear on the system, extending its lifespan. Additionally, this model is designed with a capacity suitable for medium to large spaces, making it ideal for living rooms, offices, and even small commercial areas.

Another notable feature of the AP55Q2DNUMG is its advanced filtration system, which includes a multi-layer filter designed to capture dust, allergens, and other particulate matter, ensuring that the air quality remains high. The unit also features a self-cleaning function, which helps keep the evaporator coils free from mold and mildew, further enhancing indoor air quality.

On the other hand, the Samsung AP50Q0CNAFR is designed for smaller spaces while maintaining a high level of performance and efficiency. This model also features an inverter compressor, enabling consistent temperature regulation with minimal energy consumption. The compact design of the AP50Q0CNAFR makes it a perfect fit for bedrooms, small offices, or any limited space where cooling is necessary.

Both models come equipped with Samsung's Smart Control technology, allowing users to manage their air conditioning remotely via a smartphone app. This feature provides convenience as well as flexibility, enabling users to adjust settings or set timers from anywhere, ensuring their environment is comfortable upon arrival.

In terms of energy star ratings, both models exemplify Samsung’s commitment to sustainability and energy savings. They utilize R32 refrigerant, which has a lower environmental impact and enhances energy efficiency. The sleek design of both units fits seamlessly into any decor, providing not just comfort but also aesthetic appeal.

In conclusion, the Samsung AP55Q2DNUMG and AP50Q0CNAFR represent two outstanding choices in the HVAC market, combining advanced technology, energy efficiency, and innovative features to enhance user experience while ensuring optimal climate control.