Samsung AP50Q0CNAFR, AP55Q2DNUMG Connection of Refrigerant Piping, Flare Processing, Pipe Bending

Page 25

Connection of Refrigerant Piping

When installing, make sure there is no leakage. When recovering the refrigerant, ground the compressor first before removing the connection pipe. If the refrigerant pipe is not properly connected and the compressor works with the service valve open, the pipe inhales the air and it makes the pressure inside of the refrigerant cycle abnormally high. It may cause explosion and injury.

Flare Processing

1. Cut the pipe using the pipe cutter.

90

Oblique

Roughness Burr

 

2. Insert the flare nut into the pipe, and then perform the flare processing.

Outer Diameter

A(mm)

9.52mm

1.8

19.05mm

2.2

Pipe Bending

A

1.Perform bending of the pipe using the bender which has a specified bending radius.

2.Be sure to take full care to perform bending of the pipe successfully at one time. Bending and unbending the pipe more than twice makes the bending work increasingly difficult.

3.You may use the spring inserted into the gas pipe instead of the bender to bend the pipe.

4.When you bend the pipe using the spring, hold the pipe with both hands to prevent any distortion, and secure a minimum bending radius of more than 100mm.

Spring

Tightening of Connection Parts

Align the center of the connection piping, and tighten the flare nut by turning it with hand. Then tighten it again using the torque wrench in the direction as shown in the figure.

Outer Diameter

Torque (kgf•cm)

Remarks

9.52mm

250~280

-

19.05mm

990~1210

-

E-25

Image 25
Contents Air Conditioner Safety Precautions Contents Indoor Unit View of the UnitInserting the Remote Control Batteries Remote Control-ButtonsFor Illustrations are Operating PreparationCooling Your Room Selecting the Automatic Operating Mode Changing the Room Temperature Quickly Cooling Distant Place Removing Excess Humidity Airing Your Room Selecting E. Saver Mode Adjusting the Air Flow Direction Horizontally Adjusting the Air Flow Direction VerticallyWhen Cooling UpwardsSetting the Off Timer To Cancel the Off TimerOperating Recommendations Other FunctionTopic Recommendation Cleaning Your Air Conditioner Temperature and Humidity RangesIndoor Temperature If the air conditioner is used at ThenProblem Explanation/Solution Solving Common ProblemsPower Supply Technical SpecificationsPart Name Accessory Parts ListCable tie Putty Pipe band Piping Cover hole ScrewIndoor Unit Selection of Installation PlaceOutdoor Unit Electrical Work When connecting 3Phase 3wires 220V AC When connecting 3Phase 4wires 380V ACAP50Q0C/AP50Q0D/AP55Q2C/AP55Q2D Series AP55Q0C/AP55Q0D SeriesInstallation Procedures Flare Processing Connection of Refrigerant PipingPipe Bending Tightening of Connection PartsDrilling a Hole in the Wall Connecting the PipeDrain Hose Air Purge Refrigerant Charging Check Check and Test OperationTest Operation Packing and Unpacking Guide Outdoor unit Wire tube power cable Connection sleeve How to connect your extended power cablesQuestions or COMMENTS?
Related manuals
Manual 34 pages 39.63 Kb

AP50Q0CNAFR, AP55Q2DNUMG specifications

The Samsung AP55Q2DNUMG and AP50Q0CNAFR are two advanced air conditioning units known for their innovative technology and user-friendly features. These models are designed to provide efficient cooling and heating solutions for residential and commercial spaces.

The AP55Q2DNUMG is equipped with a powerful inverter compressor, which enhances energy efficiency by adjusting the motor speed to maintain the desired temperature without frequent on-off cycles. This not only contributes to lower energy bills but also reduces wear and tear on the system, extending its lifespan. Additionally, this model is designed with a capacity suitable for medium to large spaces, making it ideal for living rooms, offices, and even small commercial areas.

Another notable feature of the AP55Q2DNUMG is its advanced filtration system, which includes a multi-layer filter designed to capture dust, allergens, and other particulate matter, ensuring that the air quality remains high. The unit also features a self-cleaning function, which helps keep the evaporator coils free from mold and mildew, further enhancing indoor air quality.

On the other hand, the Samsung AP50Q0CNAFR is designed for smaller spaces while maintaining a high level of performance and efficiency. This model also features an inverter compressor, enabling consistent temperature regulation with minimal energy consumption. The compact design of the AP50Q0CNAFR makes it a perfect fit for bedrooms, small offices, or any limited space where cooling is necessary.

Both models come equipped with Samsung's Smart Control technology, allowing users to manage their air conditioning remotely via a smartphone app. This feature provides convenience as well as flexibility, enabling users to adjust settings or set timers from anywhere, ensuring their environment is comfortable upon arrival.

In terms of energy star ratings, both models exemplify Samsung’s commitment to sustainability and energy savings. They utilize R32 refrigerant, which has a lower environmental impact and enhances energy efficiency. The sleek design of both units fits seamlessly into any decor, providing not just comfort but also aesthetic appeal.

In conclusion, the Samsung AP55Q2DNUMG and AP50Q0CNAFR represent two outstanding choices in the HVAC market, combining advanced technology, energy efficiency, and innovative features to enhance user experience while ensuring optimal climate control.