Samsung AR18HPSDBWKXMG Remote controller display, Battery changing time, Inserting the batteries

Page 15

Checking the remote controller

Remote controller display

Quiet indicator

Fast/Comfort indicator

Virus Doctor indicator

Single User indicator d'light Cool indicator

2ndF indicator

Set temperature indicator

On Timer indicator Off Timer indicator

indicator

Operation mode

indicator

Low battery indicator

Transmit indicator

Air swing indicator (Vertical, Horizontal) Fan speed indicator

Auto

Low

Medium

High

Turbo

r 01epaPr n atio

• Make sure that the water does not get to the remote controller.

Battery changing time

When the battery is exhausted, () will be displayed in the remote controller display. When the icon appears, change the batteries. The remote controller requires two 1.5 V AAA type batteries.

Storing the remote controller

When you do not use the remote controller for long time, remove the batteries from the remote controller and store it.

Inserting the batteries

1.Push the lever as arrow indicates on the rear side of the remote controller and pull up.

2.Insert two AAA batteries.

Check and match the“+”and“-” signs accordingly. Make sure you have inserted the batteries in correct position.

3.Close the cover by place it back to its original position.

You should hear click sound when the cover is locked properly.

• The signal may not be received well of electronic lighting style fluorescent lamps such as inverter fluorescent lamps

are in the same space.

• If other electrical products operate by the remote controller, call your nearest contact center.

Correct disposal of batteries in this product

(Applicable in countries with separate collection systems)

This marking on the battery, manual or packaging indicates that the batteries in this product should not be disposed of with other household waste at the end of their working life. Where marked, the chemical symbols Hg, Cd or Pb indicate that the battery contains mercury, cadmium or lead above the reference levels in EC Directive 2006/66. If batteries are not properly disposed of, these substances can cause harm to human health or the environment.

To protect natural resources and to promote material reuse, please separate batteries from other types of waste and recycle them through your local, free battery return system.

English-15

MG_BETTER_A3050_IB&IM_EN_DB68-04070A-00.indd 15

17/09/2013 11:23:12

Image 15
Contents Air Conditioner Features of your new air conditioner Contents English-4 Safety precautions01epaPr n atio English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningChecking before use Operation rangesEnglish-10 English-11 Checking the usage time English-12 Technical SpecificationsEnglish-13 Checking the name of the partsMain parts DisplayChecking the remote controller Remote controller buttonsEnglish-14 Inserting the batteries Remote controller displayBattery changing time Storing the remote controllerBasic function Basic fun n iot Press the button to adjust the temperaturePress the button to set the desired fan speed English-17English-18 Adjusting the air flow directionVertical air flow Horizontal air flowF03undAdvance n iot Using the Fast functionUsing the Comfort function English-19When the air conditioner is on and in cool/heat mode ModeEnglish-20 English-21 Setting the On/Off timerPress the On Timer or Off Timer button to set the time Press the Set/Cancel button to activate it onTurn off automatically From the moment you have set the timerEnglish-22 If the air conditioner is on If the air conditioner is offEnglish-23 Using the Single User functionUsing the Virus Doctor function Press the button on the remote controllerEnglish-24 Using the Auto Clean functionUsing the Filter reset When the air conditioner is turned onSre04 Oth Cleaning the air conditionerCleaning the outdoor unit heat exchanger English-25Remove the Air filter from the main body Cleaning the Air filterRemoving the Air filter English-26Reassembling the Air filter English-27Top of the Air filter into the main body.. ➀ English-28 Maintaining the air conditionerEnglish-29 TroubleshootingTemperature Adjustment is notHeard when refrigerant flow movement changes. It is normal Button or disconnect the power plug/switchCheck the Drains have been cleared Regular Maintenance Error is indicatedGeneral information English-31T05s In llan atio Indoor unit Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerWhere sulfide gas exists Outdoor UnitEnglish-33  Figure Description When installing more than 1 outdoor unitWhen the air outlet is towards the wall English-34Llan AccessoriesAccessories in the indoor unit case English-35Tools for test operations Accessories in the outdoor unit caseOptional accessories Tools required for installation General ToolsFixing the installation plate Assembling the hanger screwEnglish-37 Removing the screws Removing the Cover panel Before mounting the indoor unitEnglish-38 English-39 Assembling the Cover panel After mounting the indoor unitEnglish-40 Connecting the assembly cableCable specification Connecting the cableExtend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberEnglish-41 Torque English-42Smooth the cut edges Cut off the remaining foam insulationUnscrew the caps at the end of each pipe Evacuating the indoor unitCutting or extending the pipe English-43English-44 Put a flare nut slightly into the pipe and modify the flareDepth a English-45 Drain hose installationDownwards as seen in the picture Change the direction only when it is necessaryEnglish-46 ShieldDrain hole Drain plug Evacuating the connected pipesEnglish-47 Connect a drain hose to the drain plugIf you use a pipe longer than 5 m Adding RefrigerantEnglish-48 Outer TorqueEnglish-49 Performing the gas leak tests660 340 Outdoor unit installed on the wall by rackFixing the outdoor unit in place English-50English-51 Smart Install modeOff Blinking English-52English-53 Final check and trial operationAfter tube contraction work is completed, wrap it with How to connect your extended power cablesEnglish-54 Apply heat to the contraction tube to contract itMGBETTERA3050IB&IMENDB68-04070A-00.indd 17/09/2013 0211 Questions or COMMENTS?