Safety precautions

Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.

Always disconnect the air conditioner from the power supply before servicing it or accessing its internal components.

Verify that installation and testing operations are performed by qualified personnel.

Verify that the air conditioner is not installed in an easily accessible area.

General information

Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation.

For maximum safety, installers should always carefully read the following warnings.

Store the operation and installation manual in a safe location and remember to hand it over to the new owner if the air conditioner is sold or transferred.

This manual explains how to install an indoor unit with a split system with two SAMSUNG units.

The use of other types of units with different control systems may damage the units and invalidate the warranty. The manufacturer shall not be responsible for damages arising from the use of non compliant units.

This product has been determined to be in compliance with the Low Voltage Directive (2006/95/EC), and the Electromagnetic Compatibility Directive (2004/108/EC) of the European Union.

The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper connection of electric and requirements set forth in the“Operating limits”table, included in the manual, shall immediately invalidate the warranty.

The air conditioner should be used only for the applications for which it has been designed: the indoor unit is not suitable to be installed in areas used for laundry.

Do not use the units if damaged. If problems occur, switch the unit off and disconnect it from the power supply.

In order to help prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact SAMSUNG’s technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy.

Always remember to inspect the unit, electric connections, refrigerant tubes and protections regularly. These operations should be performed by qualified personnel only.

The unit contains moving parts, which should always be kept out of the reach of children.

Do not attempt to repair, move, alter or reinstall the unit. If performed by unauthorized personnel, these operations may cause electric shocks or fires.

Do not place containers with liquids or other objects on the unit.

All the materials used for the manufacture and packaging of the air conditioner are recyclable.

The packing material and exhaust batteries of the remote controller(optional) must be disposed of in accordance with current laws.

The air conditioner contains a refrigerant that has to be disposed of as special waste. At the end of its life cycle, the air conditioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and safely.

t05s In llan atio

English-31

MG_BETTER_A3050_IB&IM_EN_DB68-04070A-00.indd 31

17/09/2013 11:23:25

Image 31
Contents Air Conditioner Features of your new air conditioner Contents English-4 Safety precautions01epaPr n atio English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningOperation ranges Checking before useEnglish-10 English-11 Checking the usage timeEnglish-12 Technical SpecificationsEnglish-13 Checking the name of the partsMain parts DisplayRemote controller buttons Checking the remote controllerEnglish-14 Inserting the batteries Remote controller displayBattery changing time Storing the remote controllerBasic function Basic fun n iot Press the button to adjust the temperaturePress the button to set the desired fan speed English-17English-18 Adjusting the air flow directionVertical air flow Horizontal air flowF03undAdvance n iot Using the Fast functionUsing the Comfort function English-19Mode When the air conditioner is on and in cool/heat modeEnglish-20 English-21 Setting the On/Off timerPress the On Timer or Off Timer button to set the time Press the Set/Cancel button to activate it onTurn off automatically From the moment you have set the timerEnglish-22 If the air conditioner is on If the air conditioner is offEnglish-23 Using the Single User functionUsing the Virus Doctor function Press the button on the remote controllerEnglish-24 Using the Auto Clean functionUsing the Filter reset When the air conditioner is turned onSre04 Oth Cleaning the air conditionerCleaning the outdoor unit heat exchanger English-25Remove the Air filter from the main body Cleaning the Air filterRemoving the Air filter English-26English-27 Reassembling the Air filterTop of the Air filter into the main body.. ➀ English-28 Maintaining the air conditionerEnglish-29 TroubleshootingTemperature Adjustment is notHeard when refrigerant flow movement changes. It is normal Button or disconnect the power plug/switchCheck the Drains have been cleared Regular Maintenance Error is indicatedEnglish-31 General informationT05s In llan atio Indoor unit Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerOutdoor Unit Where sulfide gas existsEnglish-33  Figure Description When installing more than 1 outdoor unitWhen the air outlet is towards the wall English-34Llan AccessoriesAccessories in the indoor unit case English-35Tools for test operations Accessories in the outdoor unit caseOptional accessories Tools required for installation General ToolsAssembling the hanger screw Fixing the installation plateEnglish-37 Removing the Cover panel Before mounting the indoor unit Removing the screwsEnglish-38 English-39 Assembling the Cover panel After mounting the indoor unitEnglish-40 Connecting the assembly cableCable specification Connecting the cableEach wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryEnglish-41 Torque English-42Smooth the cut edges Cut off the remaining foam insulationUnscrew the caps at the end of each pipe Evacuating the indoor unitCutting or extending the pipe English-43Put a flare nut slightly into the pipe and modify the flare English-44Depth a English-45 Drain hose installationDownwards as seen in the picture Change the direction only when it is necessaryEnglish-46 ShieldDrain hole Drain plug Evacuating the connected pipesEnglish-47 Connect a drain hose to the drain plugIf you use a pipe longer than 5 m Adding RefrigerantEnglish-48 Outer TorqueEnglish-49 Performing the gas leak tests660 340 Outdoor unit installed on the wall by rackFixing the outdoor unit in place English-50English-51 Smart Install modeOff Blinking English-52English-53 Final check and trial operationAfter tube contraction work is completed, wrap it with How to connect your extended power cablesEnglish-54 Apply heat to the contraction tube to contract itMGBETTERA3050IB&IMENDB68-04070A-00.indd 17/09/2013 0211 Questions or COMMENTS?