Samsung AR24HPSDBWKXMG, AR24HCSDBWKNMG manual How to connect your extended power cables, English-54

Page 54

How to connect your extended power cables

Items to prepare

(compressor and insulation tape should be prepared by an installation technician.)

Tools

Crimping pliers

Connection sleeve (mm)

Insulation tape

Contraction tube (mm)

Spec

MH-14

20xØ7.0(HxOD)

Width 18 mm

50xØ8.0(LxOD)

Shape

 

 

 

 

1.As shown in the figure, peel off the shields from the rubber/wire of the power cable.

- Peel off 20 mm of the wire shields of the tube installed already.

• After peeling off the tube wire, you must insert a contraction tube.

2.Insert both sides of core wire of the power cable into the connection sleeve.

3.Using a compressor, compress the two points and flip it over

and compress another two points in the same location.

-The compression dimension should be 8.0.

-After compressing it, pull both sides of the wire to make sure it is firmly pressed.

4.Wrap it with the insulation tape twice and position your contraction tube in the middle of the insulation tape.

5.Apply heat to the contraction tube to contract it.

(Unit: mm)

Power cable (provided by us)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

20

 

20

60 120

180

Wire tube power cable

20

Connection sleeve

Comp. dim.

Compress it 4 times

5 mm

Insulation tape

40 mm Contraction tube

6. After tube contraction work is completed, wrap it with the

Insulation tape

insulation tape to finish.

 

• In case of extending the electric wire, please DO NOT use a round-shaped pressing socket. - Incomplete wire connections can cause electric shock or a fire.

English-54

MG_BETTER_A3050_IB&IM_EN_DB68-04070A-00.indd 54

17/09/2013 11:23:45

Image 54
Contents Air Conditioner Features of your new air conditioner Contents Safety precautions English-4English-5 01epaPr n atioFor Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9Checking before use Operation rangesEnglish-10 Checking the usage time English-11Technical Specifications English-12Display Checking the name of the partsMain parts English-13Checking the remote controller Remote controller buttonsEnglish-14 Storing the remote controller Remote controller displayBattery changing time Inserting the batteriesBasic function English-17 Press the button to adjust the temperaturePress the button to set the desired fan speed Basic fun n iotHorizontal air flow Adjusting the air flow directionVertical air flow English-18English-19 Using the Fast functionUsing the Comfort function F03undAdvance n iotWhen the air conditioner is on and in cool/heat mode ModeEnglish-20 Press the Set/Cancel button to activate it on Setting the On/Off timerPress the On Timer or Off Timer button to set the time English-21If the air conditioner is on If the air conditioner is off From the moment you have set the timerEnglish-22 Turn off automaticallyPress the button on the remote controller Using the Single User functionUsing the Virus Doctor function English-23When the air conditioner is turned on Using the Auto Clean functionUsing the Filter reset English-24English-25 Cleaning the air conditionerCleaning the outdoor unit heat exchanger Sre04 OthEnglish-26 Cleaning the Air filterRemoving the Air filter Remove the Air filter from the main bodyReassembling the Air filter English-27Top of the Air filter into the main body.. ➀ Maintaining the air conditioner English-28Adjustment is not TroubleshootingTemperature English-29Error is indicated Button or disconnect the power plug/switchCheck the Drains have been cleared Regular Maintenance Heard when refrigerant flow movement changes. It is normalGeneral information English-31T05s In llan atio Power supply line, fuse or circuit breaker Choosing the installation locationInstalling the unit Indoor unitWhere sulfide gas exists Outdoor UnitEnglish-33 English-34 When installing more than 1 outdoor unitWhen the air outlet is towards the wall  Figure DescriptionEnglish-35 AccessoriesAccessories in the indoor unit case LlanTools required for installation General Tools Accessories in the outdoor unit caseOptional accessories Tools for test operationsFixing the installation plate Assembling the hanger screwEnglish-37 Removing the screws Removing the Cover panel Before mounting the indoor unitEnglish-38 Assembling the Cover panel After mounting the indoor unit English-39Connecting the cable Connecting the assembly cableCable specification English-40Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberEnglish-41 Cut off the remaining foam insulation English-42Smooth the cut edges TorqueEnglish-43 Evacuating the indoor unitCutting or extending the pipe Unscrew the caps at the end of each pipeEnglish-44 Put a flare nut slightly into the pipe and modify the flareDepth a Drain hose installation English-45Shield Change the direction only when it is necessaryEnglish-46 Downwards as seen in the pictureConnect a drain hose to the drain plug Evacuating the connected pipesEnglish-47 Drain hole Drain plugOuter Torque Adding RefrigerantEnglish-48 If you use a pipe longer than 5 mPerforming the gas leak tests English-49English-50 Outdoor unit installed on the wall by rackFixing the outdoor unit in place 660 340 Smart Install mode English-51English-52 Off BlinkingFinal check and trial operation English-53Apply heat to the contraction tube to contract it How to connect your extended power cablesEnglish-54 After tube contraction work is completed, wrap it withMGBETTERA3050IB&IMENDB68-04070A-00.indd 17/09/2013 Questions or COMMENTS? 0211