Samsung AP55M1ANUMG General information, Installing the unit, Accessing its internal components

Page 26

Safety precautions

Carefully follow the precautions listed as below because they are essential to guarantee the safety of SAMSUNG product.

• Always disconnect the air conditioner from the power supply before servicing it or

WARNING

accessing its internal components.

Verify that installation and testing operations are performed by qualified personnel.

Verify that the air conditioner is not installed in an easily accessible area.

 

 

General information

ffCarefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation.

ffFor maximum safety, installers should always carefully read the following warnings.

ffStore the manual in a safe location and remember to hand it over to the new owner if the air conditioner is sold or transferred.

ffThis manual explains how to install an indoor unit with a split system with two SAMSUNG units. The use of other types of units with different control systems may damage the units and invalidate the warranty. The manufacturer shall not be responsible for damages arising from the use of non compliant units.

ffThe manufacturer shall not be responsible for damage originating from unauthorized changes or the improper connection of electric and hydraulic lines. Failure to comply with these instructions or to comply with the requirements set forth in the“Operating limits” table, included in the manual, shall immediately invalidate the warranty.

ffThe air conditioner should be used only for the applications for which it has been designed: the indoor unit is not suitable to be installed in areas used for laundry.

ffDo not use the units if damaged. If problems occur, switch the unit off and disconnect it from the power supply.

ffIn order to prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact SAMSUNG’s technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy.

ffAlways remember to inspect the unit, electric connections, refrigerant tubes and protections regularly. These operations should be performed by qualified personnel only.

ffThe unit contains moving parts, which should always be kept out of the reach of children.

ffDo not attempt to repair, move, alter or reinstall the unit. If performed by unauthorized personnel, these operations may cause electric shocks or fires.

ffDo not place containers with liquids or other objects on the unit.

ffAll the materials used for the manufacture and packaging of the air conditioner are recyclable.

ffThe packing material and exhaust batteries of the remote controller(optional) must be disposed of in accordance with current laws.

ffThe air conditioner contains a refrigerant that has to be disposed of as special waste. At the end of its life cycle, the air conditioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and safely.

Installing the unit

IMPORTANT : When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines. Always disassemble the electric lines before the refrigerant tubes.

ffUpon receipt, inspect the product to verify that it has not been damaged during transport. If the product appears damaged, DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the installer or the authorized technician has collected the material from the retailer).

ffAfter completing the installation, always carry out a functional test and provide the instructions on how to operate the air conditioner to the user.

ffDo not use the air conditioner in environments with hazardous substances or close to equipment that release free flames to avoid the occurrence of fires, explosions or injuries.

ENGLISH

27

PAC MIRAGE HPCO-AR-PH_IBIM_05321A-01_EN.indd 27

2015-03-03 오후 4:39:38

Image 26
Contents Look for Everywhere Features of your new air conditionerStrong Turbo/Long Function Contents Do not yank the power cable with hands Safety precautionsImportant safety symbols and precautions Severe Warning Signs FfPotential risk of personal injury Use a rated circuit breaker onlyFfPotential risk of injury or electric shock Do not open the front panel during operationFfPotential risk of personal injury or property loss Do not allow children to climb on the air conditionerFfInsufficient ventilation may result in poor performance FfWearing thick gloves can protect your hands Main parts Checking the name of the partsChecking the indoor unit and display To open the panelControl panel Heater and Purity functions are not supported by this modelChecking the remote controller Remote controller buttonsLamps are in the same space Remote controller displayUsing the remote controller Inserting the batteries Battery changing timeStoring the remote controller Indoor unitBasic operation Adjusting the desired temperature Turning on the powerSelecting the operation mode Selecting the fan speedSelecting air flow direction You cannot set the fan speed when setting the On timer Setting the On/Off timerWhen the air conditioner is off Additional options available in On timerWhen the air conditioner is on Be different from each otherWhen the air conditioner is operating in Cool or Heat mode Using the Turbo functionUsing the Long function Locking the control panel Button to adjust the fan speed Button to adjust the temperatureFfYou can increase/decrease the temperature by 1 C Cleaning the filter Air filter Cleaning and maintaining the air conditionerCleaning the exterior Type Description Maintaining your air conditionerPeriodical checks Outdoor unit after it has been started Have deposited at low temperaturesInternal protections via the unit control system Troubleshooting AppendixOperation ranges HumidityGeneral information Installing the unitAccessing its internal components Make sure that you earth the cables Power supply line, fuse or circuit breakerDo not install the air conditioner in following places Complete, electric shock or fire may occurAccessory parts list Part NameTop view Selection of installation placeIndoor unit Side viewOutdoor unit Unit for exhausted air to ventilate Preparing the installationSelecting appropriate location for installation Space requirements Wear protective goggles and mask before sprayingCord. Code designation IEC60245 IEC 66 / CENELECH07RN-F Wiring standardElectrical work AP55M0 Series Indoor and outdoor connection wiringUsing 3poles ELCBEarth Leakage Circuit Breaker AP55M1 SeriesAP55M2 Series Using 4poles ELCBEarth Leakage Circuit BreakerUsing 3poles Elcb and 2poles Elcb AF55GP1M Series Using 2poles ELCBEarth Leakage Circuit BreakerAF55GC1M Series Screw Tightening torque kgf·cm Electrical wiringConnecting the power terminal When using the rubber leg Installation methodOutdoor unit When using the anchor bolt Put the rubber leg to the outdoor unit legInstallation procedures When Wiring Oil trap Check the following list and install an oil trapRefrigerant pipe work Insulating the pipes FfHeight of the oil trap H 4R ≤ H ≤ 6RRemove burr on the edge of pipe Cut the pipe using the pipe cutterConnection of refrigerant piping Flare processing It may cause explosion and injuryDrilling a hole in the wall Pipe bendingTightening of connection parts Outer diameter mm Tightening torque kgf·cmFixing the indoor unit Wall installation Corner InstallationDrain hose ExampleAir purge Be sure that all valve cocks are closedRefrigerant charging How to add refrigerantPressure table for temperatures AP55M0AN AF55GC1M N AF55GP1M N FfCooling operationsIs grounding properly made? Check and test operationCheck Test operation Pump down procedure When removing the productWhen the outdoor temperature is below zero, do not Packing and unpacking guide Outdoor unit How to connect your extended power cables To finishProduct specification ModelQuestions or COMMENTS? Air Conditioner Thank you for purchasing this Samsung product
Related manuals
Manual 54 pages 8.23 Kb

AP55M0ANUMG, AF55GP1MBEENMG, AP55M2ANUMG, AF55GC1MBEENMG, AF55GC1MAEENMG specifications

Samsung has established a reputation for innovation in the realm of technology, particularly with its display solutions. Among its latest offerings in the market are the AP55M0AXUMG, AP55M0BNUMG, AP55M1ANUMG, AF55GC1MAEENMG, and AF55GC1MBEENMG models. These displays cater to various commercial applications, boasting impressive specifications and cutting-edge technologies that enhance user experiences.

The AP55M0AXUMG and AP55M0BNUMG are part of Samsung's premium range, featuring a stunning 55-inch display that utilizes advanced LED technology for vibrant colors and remarkable clarity. Both models support 4K resolution, ensuring that images are sharp and lifelike, which is particularly beneficial for presentations, advertising, and other commercial uses. With an ultra-narrow bezel, these displays maximize the viewing area while maintaining a sleek profile that seamlessly blends into any environment.

Equipped with powerful processors, these displays support seamless multitasking capabilities and real-time content sharing. Their compatibility with various content management systems allows users to create dynamic displays for effective engagement with their audience. The built-in Wi-Fi capabilities ensure easy connectivity, making it simple for users to update content remotely.

The AP55M1ANUMG model takes things a step further by incorporating Samsung's MagicINFO solution, which enables users to manage, schedule, and control multiple screens from a single interface. This feature is particularly advantageous for businesses that require coordinated messaging across multiple locations. Additionally, this model boasts enhanced brightness and contrast ratios, ensuring visibility even in well-lit environments.

On the other hand, the AF55GC1MAEENMG and AF55GC1MBEENMG displays cater to those seeking high-quality performance along with advanced interactive capabilities. Both models employ Samsung's innovative touch technology, allowing users to interact directly with the content displayed. This makes them ideal for educational and collaborative settings, where engagement and interactivity are paramount.

Furthermore, these displays are designed with durability in mind, featuring a robust construction that can withstand various environmental conditions. The energy-efficient design ensures lower operational costs, making them a sustainable choice for businesses looking to reduce their carbon footprint while still delivering high-impact visual experiences.

In conclusion, Samsung's AP55M0AXUMG, AP55M0BNUMG, AP55M1ANUMG, AF55GC1MAEENMG, and AF55GC1MBEENMG models are at the forefront of display technology, providing businesses and educational institutions with the tools they need to communicate effectively and capture audience attention. Their advanced features, combined with Samsung's legacy of quality, make these displays a sagacious investment for any organization seeking to elevate its digital presentation capabilities.