Samsung AP55M0BNUMG, AF55GC1MBEENMG, AP55M0AXUMG, AP55M1ANUMG, AF55GC1MAEENMG Severe Warning Signs

Page 4

WARNING

SEVERE WARNING SIGNS

Never use a damaged or dusted power cable, or loosened power receptacle. ffPotential risk of fire or electric shock.

Install an exclusive circuit breaker and short-circuit breaker for the air conditioner. ffPotential risk of electric shock or fire.

Do not insert anything such as fingers or branches into the air conditioner vents while the air conditioner is running.

ffKeep the children away from the air conditioner to prevent them from putting their finger on the air conditioner. Potential risk of personal injury.

Ensure no water gets into the air conditioner. ffPotential risk or electric shock.

fIfthe water gets into the air conditioner, stop and unplug the power source immediately.

Turn off the air conditioner using the provided remote controller or control accessory (if provided). Do not unplug to turn off the unit (unless there is an immediate danger).

Do not run the air conditioner for an extended period of time in a room with the door closed or with babies, elderly or disabled people.

ffOpen the door or windows to ventilate your room at least once an hour to prevent oxygen shortage.

The air conditioner is composed of moving parts. Keep children away from the unit to avoid physical injury.

Make sure that children take precautions against access to the air conditioner and they do not play with the unit.

Do not clean the interior of air conditioner on your own.

ffYou may damage the parts which can cause electric shock or fire. ffConsult contact center for cleaning the interior of the air conditioner.

Do not connect the air conditioner with heating apparatus or attempt to disassemble, remodel or repair it by yourself.

ffPotential risk of malfunction, electric shock or fire. If repairs are needed, consult the contact center.

Consult the place of purchase or contact center to install the air conditioner.

ffImproper installation carries a risk of unit malfunction, water leakage, electric shock or fire.

fIfinstalling in specialty areas, such as a factory complex or saline coastal area, consult the place of purchase or contact center for specific installation details.

ffThe units must be installed according to distances declared, in order to permit accessibility from each side, either

to guarantee correct operation of maintenance or repairing products. The unit’s parts must be reachable and removable completely under safety condition (for people or things).

Consult a dealer regarding the appropriate measures to prevent the allowable concentration from being exceeded.

fIfthe refrigerant leaks, and cause the concentration limit to be exceeded, hazards due to lack of oxygen in the room may result.

If the indoor unit gets wet, turn the power off immediately and call your nearest contact center.

ffPotential risk of fire or electric shock.

ENGLISH

5

PAC MIRAGE HPCO-AR-PH_IBIM_05321A-01_EN.indd 5

2015-03-03 오후 4:39:31

Image 4
Contents Strong Turbo/Long Function Features of your new air conditionerLook for Everywhere Contents Important safety symbols and precautions Safety precautionsDo not yank the power cable with hands Severe Warning Signs Use a rated circuit breaker only FfPotential risk of injury or electric shockFfPotential risk of personal injury Do not open the front panel during operationFfInsufficient ventilation may result in poor performance Do not allow children to climb on the air conditionerFfPotential risk of personal injury or property loss FfWearing thick gloves can protect your hands Checking the name of the parts Checking the indoor unit and displayMain parts To open the panelControl panel Heater and Purity functions are not supported by this modelChecking the remote controller Remote controller buttonsUsing the remote controller Remote controller displayLamps are in the same space Battery changing time Storing the remote controllerInserting the batteries Indoor unitBasic operation Turning on the power Selecting the operation modeAdjusting the desired temperature Selecting the fan speedSelecting air flow direction Setting the On/Off timer When the air conditioner is offYou cannot set the fan speed when setting the On timer Additional options available in On timerWhen the air conditioner is on Be different from each otherUsing the Long function Using the Turbo functionWhen the air conditioner is operating in Cool or Heat mode Locking the control panel FfYou can increase/decrease the temperature by 1 C Button to adjust the temperatureButton to adjust the fan speed Cleaning the exterior Cleaning and maintaining the air conditionerCleaning the filter Air filter Periodical checks Maintaining your air conditionerType Description Internal protections via the unit control system Have deposited at low temperaturesOutdoor unit after it has been started Troubleshooting AppendixOperation ranges HumidityAccessing its internal components Installing the unitGeneral information Power supply line, fuse or circuit breaker Do not install the air conditioner in following placesMake sure that you earth the cables Complete, electric shock or fire may occurAccessory parts list Part NameSelection of installation place Indoor unitTop view Side viewOutdoor unit Selecting appropriate location for installation Preparing the installationUnit for exhausted air to ventilate Space requirements Wear protective goggles and mask before sprayingElectrical work Wiring standardCord. Code designation IEC60245 IEC 66 / CENELECH07RN-F Indoor and outdoor connection wiring Using 3poles ELCBEarth Leakage Circuit BreakerAP55M0 Series AP55M1 SeriesUsing 3poles Elcb and 2poles Elcb Using 4poles ELCBEarth Leakage Circuit BreakerAP55M2 Series AF55GC1M Series Using 2poles ELCBEarth Leakage Circuit BreakerAF55GP1M Series Connecting the power terminal Electrical wiringScrew Tightening torque kgf·cm Installation method Outdoor unit When using the anchor boltWhen using the rubber leg Put the rubber leg to the outdoor unit legInstallation procedures When Wiring Check the following list and install an oil trap Refrigerant pipe work Insulating the pipesOil trap FfHeight of the oil trap H 4R ≤ H ≤ 6RCut the pipe using the pipe cutter Connection of refrigerant piping Flare processingRemove burr on the edge of pipe It may cause explosion and injuryPipe bending Tightening of connection partsDrilling a hole in the wall Outer diameter mm Tightening torque kgf·cmWall installation Corner Installation Drain hoseFixing the indoor unit ExampleAir purge Be sure that all valve cocks are closedHow to add refrigerant Pressure table for temperaturesRefrigerant charging AP55M0AN AF55GC1M N AF55GP1M N FfCooling operationsCheck Check and test operationIs grounding properly made? When the outdoor temperature is below zero, do not Pump down procedure When removing the productTest operation Packing and unpacking guide Outdoor unit How to connect your extended power cables To finishProduct specification ModelQuestions or COMMENTS? Air Conditioner Thank you for purchasing this Samsung product
Related manuals
Manual 54 pages 8.23 Kb

AP55M0ANUMG, AF55GP1MBEENMG, AP55M2ANUMG, AF55GC1MBEENMG, AF55GC1MAEENMG specifications

Samsung has established a reputation for innovation in the realm of technology, particularly with its display solutions. Among its latest offerings in the market are the AP55M0AXUMG, AP55M0BNUMG, AP55M1ANUMG, AF55GC1MAEENMG, and AF55GC1MBEENMG models. These displays cater to various commercial applications, boasting impressive specifications and cutting-edge technologies that enhance user experiences.

The AP55M0AXUMG and AP55M0BNUMG are part of Samsung's premium range, featuring a stunning 55-inch display that utilizes advanced LED technology for vibrant colors and remarkable clarity. Both models support 4K resolution, ensuring that images are sharp and lifelike, which is particularly beneficial for presentations, advertising, and other commercial uses. With an ultra-narrow bezel, these displays maximize the viewing area while maintaining a sleek profile that seamlessly blends into any environment.

Equipped with powerful processors, these displays support seamless multitasking capabilities and real-time content sharing. Their compatibility with various content management systems allows users to create dynamic displays for effective engagement with their audience. The built-in Wi-Fi capabilities ensure easy connectivity, making it simple for users to update content remotely.

The AP55M1ANUMG model takes things a step further by incorporating Samsung's MagicINFO solution, which enables users to manage, schedule, and control multiple screens from a single interface. This feature is particularly advantageous for businesses that require coordinated messaging across multiple locations. Additionally, this model boasts enhanced brightness and contrast ratios, ensuring visibility even in well-lit environments.

On the other hand, the AF55GC1MAEENMG and AF55GC1MBEENMG displays cater to those seeking high-quality performance along with advanced interactive capabilities. Both models employ Samsung's innovative touch technology, allowing users to interact directly with the content displayed. This makes them ideal for educational and collaborative settings, where engagement and interactivity are paramount.

Furthermore, these displays are designed with durability in mind, featuring a robust construction that can withstand various environmental conditions. The energy-efficient design ensures lower operational costs, making them a sustainable choice for businesses looking to reduce their carbon footprint while still delivering high-impact visual experiences.

In conclusion, Samsung's AP55M0AXUMG, AP55M0BNUMG, AP55M1ANUMG, AF55GC1MAEENMG, and AF55GC1MBEENMG models are at the forefront of display technology, providing businesses and educational institutions with the tools they need to communicate effectively and capture audience attention. Their advanced features, combined with Samsung's legacy of quality, make these displays a sagacious investment for any organization seeking to elevate its digital presentation capabilities.