Samsung AR09FSFPKGMNZE manual Purging the indoor unit, Cutting or extending the pipe, Depth a

Page 35

Purging the indoor unit

The indoor unit is supplied with inert gas (nitrogen).

Before installing the unit, check if nitrogen gas flow out of indoor unit.

If this one isn’t true, DO NOT INSTALL THE UNIT since leakage could be inside the indoor unit.

1.Unscrew the caps at the end of each pipe.

All inert gas exhausts from the indoor unit.

• To prevent dirt or foreign substances from getting into the pipes during

installation, do NOT remove the caps completely until you are ready to connect the pipes.

The remaining air in the Refrigeration cycle, which contains moisture,

 

 

 

 

 

 

 

may cause malfunction on the compressor.

Pipes

 

Unscrew the caps

Always contact the service center or a professional installation agency

 

 

 

 

for product installation.

Cutting or extending the pipe

The length of the pipe can be:

Extended up to : see table page 28

Shorten up to: see page 28

If you need a pipe longer than 5 meters:

• You must extend the assembly cable.

You must add refrigerant to the pipes; otherwise, the indoor unit may freeze.

1.Make sure that you have all the required tools (pipe cutter, reamer, flaring tool and pipe holder).

2.If you want to shorten the pipe, cut it using a pipe cutter, ensuring that the cut edge remains at 90° with the side of the pipe (see below examples of correct and incorrect cut edges).

Pipe

Oblique

Rough

Burr

cutter

 

 

 

Pipe

ENGLISH

3. To prevent a gas leak, remove all burrs at the cut edge of the pipe using a reamer.

• Face the pipe down while removing the burrs to make sure that burrs do not get in to the pipe.

4. Put a flare nut slightly into the pipe and modify the flare.

Pipe

Flare

Outer Diameter (D)

Depth (A)

Flaring Size (B)

 

 

 

ø6.35 mm

1.3 mm

9.0 mm

ø9.52 mm

1.8 mm

13.0 mm

ø12.70 mm

2.0 mm

16.2 mm

ø15.88 mm

2.2 mm

19.3 mm

ø19.05 mm

2.2 mm

22.5 mm

ø22.23 mm

2.2 mm

25.7 mm

35

Maldives ZE_AR09FSFP@_IBIM_DB68-03379A_EN.indd 35

2012-12-8 9:09:08

Image 35
Contents Maldives ZEAR09FSFP@IBIMDB68-03379AEN.indd 2012-12-8 Contents Personal injury or property damage Safety precautionsImportant safety symbols and precautions Personal injury or deathFor Installation Caution For Using Do not touch the circuit breaker with wet hands Do not place objects or devices under the indoor unit Do not touch the pipes connected with the product Do not operate the appliance with wet handsDo not drink the water from the air conditioner Do not clean the inside of the air conditioner by yourself For CleaningModel AJ Checking before useOperation ranges Display Power buttonChecking the name of the parts Main partsRemote controller buttons Checking the remote controllerInserting the batteries Remote controller displayBattery changing time Storing the remote controllerBasic function Press Button to adjust the temperatureVertical air flow Adjusting the air flow directionUsing the Turbo function Press the Air swing button on the remote controllerPress the Time Up or Time Down button to set the time When the air conditioner is on and in cool/heat modePress the button on the remote controller ModeAdditional options available in On timer mode Setting the On/Off timerPress the On Timer/Off Timer button Cancel Press the Cancel buttonTurn off automatically Using the Smart Saver functionFrom the moment you have set the timer If the air conditioner is on If the air conditioner is offYou can reduce the noise generated from an indoor unit Using the Quiet functionUsing the Auto Clean function When the air conditioner is turned onCleaning the outdoor unit heat exchanger Cleaning the air conditionerMake sure the power is turned off and unplugged from Cleaning the indoor unitDry the Air filter in a ventilated area Cleaning the air filterRemoving the Air filter Open the panel and put the Air filter outMaintaining the air conditioner Clean the condensate drain panTroubleshooting Service center Working Cannot adjust the temperature Fan speedTimer function Does not set After you have set the time IndicatorIncluded Models Remark General information a place where the air filter can be replaced easily Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerOutdoor Unit Where sulfide gas existsTop view Side view When installing more than 1 outdoor unitWhen the air outlet is towards the wall  Figure DescriptionAccessories in the outdoor unit case AccessoriesAccessories in the indoor unit case Tools for test operations Fixing the installation plateOptional accessories Tools required for installation General ToolsConnecting the cable Connecting the assembly cableCable specification Each wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryCut off the remaining foam insulation Smooth the cut edgesPut a flare nut slightly into the pipe and modify the flare Purging the indoor unitCutting or extending the pipe Unscrew the caps at the end of each pipeOuter Diameter Pipe 50 Pa. The joint must be accessible and serviceableCorrect Inclined CrackedChanging direction of the drain hose Drain hose installationEnsure that condensation draining is adequate Purging the connected pipesConnect a drain hose to the drain plug Model Adding RefrigerantIf you use a pipe longer than 5m If you use a pipe shorter than 5m1975 Please fill in with indelible ink the factory refrigerant charge of the product Leak test with nitrogen before opening valves Performing the gas leak testsTo check for gas leaks on the outdoor unit To check for gas leaks on the indoor unitFixing the outdoor unit in place Then place the indoor unit on the installation plateFixing the indoor unit in place Final Check and Trial Operation Insulation tape to finish How to connect your extended power cablesApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withAssemble the Cover PCB and the front panel Sub PCB installationoptionalWried remote controller, central remote controller etc Only for multi systemQuestions or COMMENTS? Air Conditioner
Related manuals
Manual 46 pages 39.71 Kb Manual 45 pages 27.27 Kb Manual 1 pages 30.76 Kb Manual 45 pages 23.86 Kb Manual 1 pages 26.59 Kb Manual 1 pages 28.23 Kb Manual 45 pages 14.41 Kb Manual 45 pages 15.07 Kb Manual 45 pages 25.41 Kb

AR09FSFPKGMNZE, AR12FSFPKGMNZE, AR09FSFPKGMNET, AR12FSFPKGMNET specifications

The Samsung AR12FSFPKGMNET, AR12FSFPKGMXZE, AR12FSFPKGMNZE, and AR12FSFPKGMXET are part of Samsung's cutting-edge line of air conditioners designed to offer efficient cooling and heating solutions for modern living spaces. These models are well-known for their innovative technologies, sleek designs, and energy-efficient performance, making them ideal for residential and commercial applications.

One of the standout features of these units is the Digital Inverter technology, which significantly reduces energy consumption compared to conventional models. By adjusting the compressor speed according to the cooling demand, the Digital Inverter maintains a consistent temperature while minimizing energy use, leading to lower utility bills. This technology also helps in reducing noise levels, providing you with a peaceful indoor environment.

In addition to energy efficiency, these air conditioners incorporate Samsung's unique Tri-Care Filter system. This advanced filtration technology effectively removes dust, allergens, and harmful particles from the indoor air, ensuring a healthier living space. The filters are easy to clean and can be accessed conveniently, promoting better maintenance practices.

Another important characteristic of the Samsung AR series is the Fast Cooling mode. This function allows the air conditioner to rapidly cool the room during hot weather, providing swift relief from heat. The powerful mode is particularly beneficial during the sweltering summer months when immediate cooling is essential.

The Smart Control feature is another significant innovation found in these models. Users can effortlessly control their air conditioners through a smartphone app, providing convenience and flexibility. With Smart Control, you can adjust temperatures, set timers, and monitor energy consumption from anywhere, making it easy to manage your indoor climate remotely.

Additionally, the design of the AR12FSFPKGMNET, AR12FSFPKGMXZE, AR12FSFPKGMNZE, and AR12FSFPKGMXET models is sleek and modern, allowing them to blend seamlessly into any interior decor. The compact size and subtle styling ensure a good fit for various room sizes, enhancing the aesthetic of the space while providing outstanding performance.

In conclusion, the Samsung AR12FSFPKGMNET, AR12FSFPKGMXZE, AR12FSFPKGMNZE, and AR12FSFPKGMXET air conditioners embody a perfect blend of advanced technology, energy efficiency, and user-friendly features, making them a top choice for consumers seeking reliable and stylish cooling solutions.