Purging the connected pipes

Important information regulation regarding the refrigerant used

This product contains fluorinated greenhouse gases covered by the Kyoto Protocol.

Do not vent gases into the atmosphere.

1.Please fill in with indelible ink,

the factory refrigerant charge of the product,

the additional refrigerant amount charged in the field and

+the total refrigerant charge. on the refrigerant charge label supplied with the product.

a. Factory refrigerant charge of the product: see unit name plate

b.Additional refrigerant amount charged in the field (Refer to the above information for the quantity of refrigerant replenishment.)

c.Total refrigerant charge

d.Refrigerant cylinder and manifold for charging

Refrigerant type

GWP value

R-410A

1975

GWP=Global Warming Potential

Contains fluorinated greenhouse gases covered by the Kyoto Protocol.

Indoor unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

d

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a

 

 

 

 

 

 

 

 

 

 

Outdoor unit

= (

 

 

) kg

 

 

 

 

 

 

 

= (

 

 

) kg += (

 

) kg

 

 

 

b

 

 

 

 

c

• The filled-out label must be adhered in the proximity of the product charging port (e.g. onto the inside of the stop valve cover).

Charging the refrigerant under conditions of liquid by using a liquid pipe

R-410A is a mixed type of refrigerant. It is necessary for recharging under conditions of liquid. When recharging refrigerant from the refrigerant cylinder to the equipment, follow the instructions below.

1.Before recharging, check whether the cylinder has a siphon or not. There are two ways to recharge the refrigerant.

Cylinder with siphon

Cylinder without siphon

siphon

Charge the refrigerant standing the cylinder upright.

Charge the refrigerant turning the cylinder upside down.

• If R-410A refrigerant is charged with gas, the composition of the charged refrigerant changes and the

characteristics of the equipment vary.

During the measuring operation of refrigerant quantity added use an electronic balance.

If cylinder doesn’t have syphon, upset it.

40

Maldives ZE_AR09FSFP@_IBIM_DB68-03379A_EN.indd 40

2012-12-8 9:09:09

Image 40
Contents Maldives ZEAR09FSFP@IBIMDB68-03379AEN.indd 2012-12-8 Contents Safety precautions Important safety symbols and precautionsPersonal injury or death Personal injury or property damageFor Installation Caution For Using Do not touch the circuit breaker with wet hands Do not place objects or devices under the indoor unit Do not drink the water from the air conditioner Do not operate the appliance with wet handsDo not touch the pipes connected with the product For Cleaning Do not clean the inside of the air conditioner by yourselfOperation ranges Checking before useModel AJ Power button Checking the name of the partsMain parts DisplayChecking the remote controller Remote controller buttonsRemote controller display Battery changing timeStoring the remote controller Inserting the batteriesBasic function Button to adjust the temperature PressAdjusting the air flow direction Using the Turbo functionPress the Air swing button on the remote controller Vertical air flowWhen the air conditioner is on and in cool/heat mode Press the button on the remote controllerMode Press the Time Up or Time Down button to set the timeSetting the On/Off timer Press the On Timer/Off Timer buttonCancel Press the Cancel button Additional options available in On timer modeUsing the Smart Saver function From the moment you have set the timerIf the air conditioner is on If the air conditioner is off Turn off automaticallyUsing the Quiet function Using the Auto Clean functionWhen the air conditioner is turned on You can reduce the noise generated from an indoor unitCleaning the air conditioner Make sure the power is turned off and unplugged fromCleaning the indoor unit Cleaning the outdoor unit heat exchangerCleaning the air filter Removing the Air filterOpen the panel and put the Air filter out Dry the Air filter in a ventilated areaClean the condensate drain pan Maintaining the air conditionerTroubleshooting Working Cannot adjust the temperature Fan speed Timer functionDoes not set After you have set the time Indicator Service centerGeneral information Included Models RemarkChoosing the installation location Installing the unitPower supply line, fuse or circuit breaker  a place where the air filter can be replaced easilyWhere sulfide gas exists Outdoor UnitWhen installing more than 1 outdoor unit When the air outlet is towards the wall Figure Description Top view Side viewAccessories in the indoor unit case AccessoriesAccessories in the outdoor unit case Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsCable specification Connecting the assembly cableConnecting the cable Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberSmooth the cut edges Cut off the remaining foam insulationPurging the indoor unit Cutting or extending the pipeUnscrew the caps at the end of each pipe Put a flare nut slightly into the pipe and modify the flarePipe 50 Pa. The joint must be accessible and serviceable Correct InclinedCracked Outer DiameterDrain hose installation Changing direction of the drain hoseConnect a drain hose to the drain plug Purging the connected pipesEnsure that condensation draining is adequate Adding Refrigerant If you use a pipe longer than 5mIf you use a pipe shorter than 5m Model the factory refrigerant charge of the product Please fill in with indelible ink1975 Performing the gas leak tests To check for gas leaks on the outdoor unitTo check for gas leaks on the indoor unit Leak test with nitrogen before opening valvesFixing the indoor unit in place Then place the indoor unit on the installation plateFixing the outdoor unit in place Final Check and Trial Operation How to connect your extended power cables Apply heat to the contraction tube to contract itAfter tube contraction work is completed, wrap it with Insulation tape to finishSub PCB installationoptional Wried remote controller, central remote controller etcOnly for multi system Assemble the Cover PCB and the front panelQuestions or COMMENTS? Air Conditioner
Related manuals
Manual 46 pages 39.71 Kb Manual 45 pages 27.27 Kb Manual 1 pages 30.76 Kb Manual 45 pages 23.86 Kb Manual 1 pages 26.59 Kb Manual 1 pages 28.23 Kb Manual 45 pages 14.41 Kb Manual 45 pages 15.07 Kb Manual 45 pages 25.41 Kb

AR09FSFPKGMNZE, AR12FSFPKGMNZE, AR09FSFPKGMNET, AR12FSFPKGMNET specifications

The Samsung AR12FSFPKGMNET, AR12FSFPKGMXZE, AR12FSFPKGMNZE, and AR12FSFPKGMXET are part of Samsung's cutting-edge line of air conditioners designed to offer efficient cooling and heating solutions for modern living spaces. These models are well-known for their innovative technologies, sleek designs, and energy-efficient performance, making them ideal for residential and commercial applications.

One of the standout features of these units is the Digital Inverter technology, which significantly reduces energy consumption compared to conventional models. By adjusting the compressor speed according to the cooling demand, the Digital Inverter maintains a consistent temperature while minimizing energy use, leading to lower utility bills. This technology also helps in reducing noise levels, providing you with a peaceful indoor environment.

In addition to energy efficiency, these air conditioners incorporate Samsung's unique Tri-Care Filter system. This advanced filtration technology effectively removes dust, allergens, and harmful particles from the indoor air, ensuring a healthier living space. The filters are easy to clean and can be accessed conveniently, promoting better maintenance practices.

Another important characteristic of the Samsung AR series is the Fast Cooling mode. This function allows the air conditioner to rapidly cool the room during hot weather, providing swift relief from heat. The powerful mode is particularly beneficial during the sweltering summer months when immediate cooling is essential.

The Smart Control feature is another significant innovation found in these models. Users can effortlessly control their air conditioners through a smartphone app, providing convenience and flexibility. With Smart Control, you can adjust temperatures, set timers, and monitor energy consumption from anywhere, making it easy to manage your indoor climate remotely.

Additionally, the design of the AR12FSFPKGMNET, AR12FSFPKGMXZE, AR12FSFPKGMNZE, and AR12FSFPKGMXET models is sleek and modern, allowing them to blend seamlessly into any interior decor. The compact size and subtle styling ensure a good fit for various room sizes, enhancing the aesthetic of the space while providing outstanding performance.

In conclusion, the Samsung AR12FSFPKGMNET, AR12FSFPKGMXZE, AR12FSFPKGMNZE, and AR12FSFPKGMXET air conditioners embody a perfect blend of advanced technology, energy efficiency, and user-friendly features, making them a top choice for consumers seeking reliable and stylish cooling solutions.