Enviro C-11500 owner manual Secondary Installation, Log Placement of Rear Log Chunks

Page 25

Secondary Installation

Installation of Log Set:

The placement of the logs is not arbitrary. If they are positioned incorrectly, the flames can be “pinched” and will not burn correctly. The burner has four (4) pins and four (4) ledges which make alignment easier. Using the pictures provided, carefully set the logs in place.

NOTE: The logs are fragile and should be handled gently.

1.Carefully remove logs from box and check there is no damage. It is very important to install all logs in their proper position to ensure safe, optimum operating conditions.

2.Place the Left Rear Log Chunk on the two (2) left rear pins and the Right Rear Log Chunk on the two (2) right rear pins (refer to Figures 37 and 38).

3.Place the bottom of the “Y” Log in the ledge at the front left of the burner and the top of the log rests on the Right Rear Log Chunk as shown in Figure 38 and 39.

4.Place the bottom of the Right Log in the ledge at the front right of the burner and rest the top of the log against the rear panel as shown in Figure 39 and 40.

Figure 37: Log Placement of Rear Log Chunks.

Figure 38: Log Placement of “Y” Log.

Figure 39: Log Placement of Right Log.

25

Image 25
Contents Cara DR General Safety PrecautionsTable of Contents Vented GAS Fireplace Heater Cara DR DV NG/LPG Codes And ApprovalsThis Enviro Cara DR Fireplace Cara DR Exterior Dimensions SpecificationsOperating Instructions For Your Safety Read Before OperatingCara Component Sound & Reason Pilot Flame Maintenance And ServiceNo substitute materials are allowed Check burner for proper operation Conversion Kit Installation Kit Parts ListCheck that the screw is clean and if necessary remove dirt Qualified Installers only Initial InstallationManufacturer Trade Name Nominal Sizes Vent Termination Restrictions Twist-Lock 51mm at top, 1½ 38mm at sides, 1½ 38mm at bottomSurface Attach With Installation for Cara DR Natural Gas Propane Main Burner Venturi SettingManifold Pressure Min. Manifold PressureCanadian Installations Wire Size Max. LengthA. Installations Optional Blower Fan Installation Keep Clear of ALL Obstructions Initial Installation Log Placement of Rear Log Chunks Secondary InstallationLog Placement of Left Log Remove door to clean glass Addition the seven 7 small rocks. These can be To clean glass Problem Possible Cause Solution Trouble ShootingReference Part Description Part Number Parts ListParts List Parts Diagram To the Dealer WarrantyWarranty Warranty Installation Data Sheet