Operating Instructions

For Your Safety, Read Safety Precautions

And Lighting Instructions Before Operating

The ideal flame will be blue at the base and light orange above. The flames should be of medium height. If the flames look like this (refer to Figure Figure 43 or Front Cover), no adjustment is needed. If the flames are fairly short and mostly blue, the fireplace is getting too much air. Therefore, the air shutter should be closed slightly until the correct flames are achieved. Flames that are very orange, with tall, dark, stringy tips, are not getting enough air. Open the air shutter until the flames clean up. If the shutter is opened, or closed all the way, and the correct flames cannot be attained, turn off the gas and contact the dealer.

Warning: Incorrect air shutter adjustment may lead to improper combustion, which is a safety hazard. Contact the dealer if there is any concern about the venturi adjustment.

Table 1: Air Shutter Setting Information.

 

Natural Gas

Propane

 

 

 

Amount Air Shutter is Open

¼” (6mm) minimum

Completely Open

 

 

 

Remote controls (Optional):

This fireplace can use an optional remote control or an optional cordless wall thermostat. If either of these are to be used to control the fireplace for the majority of the time, leave the ON/OFF switch (on the rear of the unit) in the “ON” position. Consult the instructions included with the remote/wall thermostat for operation guidelines.

Blower Speed (Optional):

The blower will come on only when the fireplace is up to temperature (approximately 12 minutes with unit on high). When installed, the blower is equipped with a variable fan controller, located in the front control panel. This control will adjust the fan speed from high to low or turn the fan off.

Normal Sounds During Operation:

 

Table 2: Normal Sounds

 

 

Component

Sound & Reason

 

 

Cara

Creaking when heating up or cooling down.

 

 

Burner

Light pop or poof when turned off; this is more common with LP units.

 

 

Temperature Sensor

Clinking when it senses to turn the blower on or off.

Pilot Flame

Quiet whisper while the pilot flame in on.

Blower / Fan

Air movement that increase and decreases with the speed of the blower.

 

The blower is pushing the heat from the fireplace into the room.

Gas Control Valve

Dull click when turning on or off, this is the valve opening and closing.

 

 

8

Image 8
Contents Cara DR Safety Precautions GeneralTable of Contents This Enviro Cara DR Fireplace Codes And ApprovalsVented GAS Fireplace Heater Cara DR DV NG/LPG Specifications Cara DR Exterior DimensionsFor Your Safety Read Before Operating Operating InstructionsCara Component Sound & Reason Maintenance And Service Pilot FlameNo substitute materials are allowed Check burner for proper operation Kit Parts List Conversion Kit InstallationCheck that the screw is clean and if necessary remove dirt Initial Installation Qualified Installers onlyManufacturer Trade Name Nominal Sizes Vent Termination Restrictions 51mm at top, 1½ 38mm at sides, 1½ 38mm at bottom Twist-LockSurface Attach With Installation for Cara DR Venturi Setting Natural Gas Propane Main BurnerManifold Pressure Min. Manifold PressureA. Installations Wire Size Max. LengthCanadian Installations Optional Blower Fan Installation Keep Clear of ALL Obstructions Initial Installation Secondary Installation Log Placement of Rear Log ChunksLog Placement of Left Log Remove door to clean glass Addition the seven 7 small rocks. These can be To clean glass Trouble Shooting Problem Possible Cause SolutionParts List Reference Part Description Part NumberParts List Parts Diagram Warranty To the DealerWarranty Warranty Installation Data Sheet