Enviro C-11500 owner manual Cara

Page 7

Operating Instructions

For Your Safety, Read Safety Precautions

And Lighting Instructions Before Operating

Low

Ignitor

High

On/Off

 

 

Fan

 

 

 

Remote Control Receiver

 

 

(optional)

 

Off

Cara

Figure 4: Cara DR Control Panel.

Air Shutter:

The air shutter is controlled by sliding the air shutter adjustment screw (shown in Figure 5) either forwards or backwards. The adjustment screw, for the primary air, is located on the bottom of the firebox. The air shutter nut can be accessed by removing the control panel. This is best done during the initial installation.

Sliding the shutter forwards increases the primary air while sliding the shutter backwards decreases the primary air.

The air shutter allows the amount of air coming into the fireplace to be adjusted in order to accommodate different climates and venting arrangements. Start the pilot and then the burner. Make sure the pilot flame is burning normally and none of the burner ports are plugged. Let the fireplace burn for roughly fifteen

(15)minutes and then examine the flames, compare the flames to Figure 43 or Front Cover.

Air Shutter Adjustment Nut

Figure 5: Air Shutter Adjustment.

7

Image 7
Contents Cara DR General Safety PrecautionsTable of Contents Vented GAS Fireplace Heater Cara DR DV NG/LPG Codes And ApprovalsThis Enviro Cara DR Fireplace Cara DR Exterior Dimensions SpecificationsOperating Instructions For Your Safety Read Before OperatingCara Component Sound & Reason Pilot Flame Maintenance And ServiceNo substitute materials are allowed Check burner for proper operation Conversion Kit Installation Kit Parts ListCheck that the screw is clean and if necessary remove dirt Qualified Installers only Initial InstallationManufacturer Trade Name Nominal Sizes Vent Termination Restrictions Twist-Lock 51mm at top, 1½ 38mm at sides, 1½ 38mm at bottomSurface Attach With Installation for Cara DR Min. Manifold Pressure Venturi SettingNatural Gas Propane Main Burner Manifold PressureCanadian Installations Wire Size Max. LengthA. Installations Optional Blower Fan Installation Keep Clear of ALL Obstructions Initial Installation Log Placement of Rear Log Chunks Secondary InstallationLog Placement of Left Log Remove door to clean glass Addition the seven 7 small rocks. These can be To clean glass Problem Possible Cause Solution Trouble ShootingReference Part Description Part Number Parts ListParts List Parts Diagram To the Dealer WarrantyWarranty Warranty Installation Data Sheet