Samsung SHR-3010P manual Rear View

Page 7

DIGITAL VIDEO RECORDER

GB

 

GB

 

Rear View

1

2

3

4

5

6

7

8

9

10

11

No

Name

 

Function

 

No

Name

 

Function

 

 

 

 

 

EXTERNAL I/O

 

ALARM IN: In the N.C. (Normally Closed) mode, the system

1

RS232 PORT

Serial Port for remote control.

 

8

 

 

 

 

 

 

PORT

 

recognizes an alarm when a High (5V) signal is input for over

2

RS485 PORT

Serial Port for remote control.

 

 

 

0.5 seconds. In the N.O. (Normally Open) mode, the system

 

 

 

 

 

 

 

 

recognizes an alarm when a Low (0V) signal is input for over

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.5 seconds. (Please refer to “ALARM DETECT TYPE”

3

VIDEO IN/OUT

Composite image signal I/O terminal (BNC Style Connector).

 

 

 

 

 

 

 

 

on p. 3-18.)

 

 

 

 

 

 

 

ALARM RESET: The alarm mode is cleared when a Low (0V)

 

 

 

 

 

 

 

4

AUDIO IN/OUT

Audio Signal Input/Output Jacks (RCA Jacks).

 

 

 

 

signal is input for over 0.5 seconds.

 

 

 

 

 

 

 

ALARM OUT: A High (5V) signal is output during alarm

5

LAN

LAN Cable Connection Terminal.

 

 

 

 

recording.

 

 

 

TRIGGER OUT: This signal is for switching the recording

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

output screen of the Multiplexer.

6

MODE

 

 

 

 

 

 

It is the DIP switch to set System ID, Direct Communication,

 

 

 

REC IN: The system begins recording when a Low (0V) signal

 

 

Termination, etc.

 

 

 

 

is input for over 0.5 seconds.

 

 

1~5

: System ID. (Depending on you turn the switch on and

 

 

 

DISK END: If the DISK END MODE of the RECORD

 

 

 

off, it will be set to High(1) and Low(0) respectively.)

 

 

 

 

MODE SETUP is set to STOP, a Low (0V) signal is output for

 

 

6

: Not Use.

 

 

 

 

about 1 second when the HDD becomes full during recording.

 

 

7

: Termination On/Off (Of all the directly connected

 

 

 

 

(Please refer to “DISK END MODE” on p. 3-16.)

 

 

 

 

 

 

 

 

 

 

systems, it sets the last system as On).

 

 

 

 

 

 

 

 

 

FAN

Fan

 

 

 

(Depending on you turn the switch on and off, it will

 

9

 

 

 

be set to Off and On respectively.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

: Not Use.

 

10

AC IN

Connects power cable.

 

 

 

 

 

 

 

7

SCSI

SCSI Connector for Data Backup

 

 

 

 

 

 

11

POWER

Power On/Off button.

 

 

 

 

 

 

 

 

 

1-5

1-6

Image 7
Contents Digital Video Recorder Digital Video Recorder Important Safety InstructionsContents Summary Variously changing numbers of recording fields per second Introduction CharacteristicsConvenient retrieval function Full PowerAlarm 3Name and Function of Each PartRear View Mounting HDD Unpacking HDD AdditionMode setup and cable connection II. Connection with Other Devices Connection with Multiplexer Connection to External DevicesCommunication Method RS-232C terminal D-SUB 9 Pin and Pin specificationsConnection with PC for Use Connection with RS-232CData Format Samsung Protocol RS-485 terminal and Pin specificationsConnection with RS-485 Code value by keyIII. Basic Method to use Power On 1Booting the SystemRecognizing incoming video signal 2Basic Screen Viewing Power OffLive Screen Viewing Playback screen Viewing 3Menu View Menu Enter Change of SettingsMove to Parent Menu or Menu End Menu Move Or Down Button so current second is displayed Example of menu setting in case of changing timeEach menu item ② Picture Quality 5Record Setup➃ Disk END Mode ① Audio Record6Alarm Record Setup ➅ Post Alarm Time Limit ⑨ SET Area & Sensitivity ➄ PRE Alarm Time Limit ⑧ Motion Detection➆ Main Alarm Picture Rate Move 7Reservation Record SetupSize LeftSystem Setup Communication Setup System Information Backup from Record Event ListCancel = Stop ⑧ Backup Screen① from Date 2003 Date to start backup To Date 2003 Date to end backupSearch & Play of Back UP Backup image search and replay 2BACKUP from Alarm Event ListReference Scsi Erase Scsi HDD Recording Deletion Mode SetupIV. Record Basic Record 1Basic Record② Record Stop ① Current Image Record Record Lock Record Lock Alarm RecordRecord in Alarm Occurrence Release of Alarm RecordReservation Record Cancel Reservation Record Setup4Reservation Record Retrieval Menu Enter ① CLOCK/DISPLAY Mode Setup ➂ Alarm Event Search② Record Event Search ➃ Power Event List 1Retrieval Menu ViewRetrieval by Date and Time Recorded Data List View 000052 Alarm Record Retrieval Power On/Off Status List View6Basic Playback Play in Various Speed 7Various Screen View Using JOG/SHUTTLEView by Field VI. Others Product Standards Appearance Drawing BackupHDD VII. Appendices Trouble Check Points 1Check Points before Call Service CenterQuestion Answer AB68-00377A
Related manuals
Manual 45 pages 53.72 Kb