Samsung SHR-3010P manual System Setup Communication Setup

Page 26

DIGITAL VIDEO RECORDER

GB

 

 

GB

 

9

8

 

 

System Setup

Communication Setup

The following illustrates the intial setting of the SYSTEM SETUP menu.

SYSTEM SETUP

PASSWORD

****

PASSWORD LOCK

OFF

HDD ERASE

OFF

FACTORY RESET

OFF

MENU SCREEN

DARK GRAY

LANGUAGE

ENGLISH

PASSWORD

Set the system password. You can enter a 4-digit number and the initial set value is 0000.

PASSWORD LOCK

If you set this to ON, you can ask for a password, which is set in the PASSWORD, each time the MENU button is pressed or the recording lock cancellation is attempted during the recording, and stop the respective operation if wrong password is entered. If set to OFF, you do not have to enter password for each case metioned above. [ON/OFF]

HDD ERASE

If you set to ON and exit the menu, the system will delete all data stored on the HDD. [ON/OFF]

Caution

Verify once again that is is OK to delete the data, as deleted data cannot be restored.

FACTORY RESET

If you set to ON and finish the menu, all settings will be restored to their factory default settings. However, the data on the HDD will not be deleted. [ON/OFF]

MENU SCREEN

If this is set to DARK GRAY, the background of the screen becomes darker when the MENU button is pressed and you will not be able to see the characters clearly. If set to OFF, you can see the current video clearly even when the MENU button is pressed. [DARK GRAY/OFF]

MULTIPLEXER SELECT

The settings of all recording modes will be dependent on the Multiplexer setting. The corresponding Multiplexers are SAMSUNG SDM-160(SDM-090), SMO-150(SMO-210, SOM-080).

LANGUAGE (MULTI-LANGUAGE SUPPORT)

Besides English, multi-language support provides German, French, Italian, and Spanish. You can conveniently set the desired language. The default language is set to English.

[ENGLISH/DEUTSCH/FRANÇAIS/ESPAÑOL/ITALIANO]

The following illustrates the intial setting of the COMMUNICATION SETUP menu.

COMMUNICATION SETUP

BAUD RATE

115,200

 

NETWORK ACCESS

ON

 

 

 

IP ADDRESS

0.

0.

0.

0

GATEWAY

0.

0.

0.

0

SUBNET MASK

0.

0.

0.

0

NETWORK USER ID

****

 

 

 

NETWORK USER PWD

****

 

 

 

PAN/TILT TYPE

SCC-641

 

 

 

 

 

 

BAUD RATE

Sets data transmission rate in RS-232C communication.

[4,800/9,600/19,200/38,400/115,200]

NETWORK ACCESS/IP ADDRESS/GATEWAY/SUBNET MASK

If the system is connected to a LAN, it can be controlled from the remote surveillance pro- gram installed on a remote PC. To connect to a LAN, set the NETWORK ACCESS to ON, and configure the IP ADDRESS, GATEWAY, SUBNET MASK, etc. to suit the user’s net- work environment. Then, connect the LAN Cable to the LAN Cable connection terminal on the back of the system and reboot the system. If at least one from the IP ADDRESS, GATEWAY, and SUBNET MASK is modified, the system must be rebooted to apply the modified setting to the system.

NETWORK USER ID/NETWORK USER PWD

In order to access the system through a LAN from a remote surveillance program installed on a remote PC, the user ID and password must be entered. At this time, the user ID and password entered match the ones set in the NETWORK USER ID and NETWORK USER PWD, you can connect to the system; otherwise, you cannot gain access. Both are 4-digit numbers and the initial set values are 0000.

PAN/TILT TYPE (Remote Control of Camera)

You can control the Pan/Tilt/Zoom function of a camera with the remote monitoring program installed in the remote PC through LAN. Then, you shall select the camera to be controlled. But, this remote control shall be applied only to SEC SCC-641, 643 Camera, and SCC-421 Series (C4201, C4203, C4310, C4303) Camera which use the SAMSUNG Protocol. You can select the camera to be controlled by the remote monitoring program. Please refer to Remote Monitoring Program Use’s Manual for the detailed explanation of the remote monitoring program.

[SCC-641/SCC-421]

3-23

3-24

Image 26
Contents Digital Video Recorder Important Safety Instructions Digital Video RecorderContents Summary Convenient retrieval function Introduction CharacteristicsVariously changing numbers of recording fields per second 3Name and Function of Each Part PowerAlarm FullRear View Unpacking HDD Addition Mounting HDDMode setup and cable connection II. Connection with Other Devices Connection to External Devices Connection with MultiplexerConnection with RS-232C RS-232C terminal D-SUB 9 Pin and Pin specificationsConnection with PC for Use Communication MethodCode value by key RS-485 terminal and Pin specificationsConnection with RS-485 Data Format Samsung ProtocolIII. Basic Method to use Recognizing incoming video signal 1Booting the SystemPower On Power Off 2Basic Screen ViewingLive Screen Viewing Playback screen Viewing Move to Parent Menu or Menu End Menu Move Menu Enter Change of Settings3Menu View Example of menu setting in case of changing time Or Down Button so current second is displayedEach menu item ① Audio Record 5Record Setup➃ Disk END Mode ② Picture Quality 6Alarm Record Setup ➆ Main Alarm Picture Rate ➄ PRE Alarm Time Limit ⑧ Motion Detection➅ Post Alarm Time Limit ⑨ SET Area & Sensitivity Left 7Reservation Record SetupSize MoveSystem Setup Communication Setup Backup from Record Event List System InformationTo Date 2003 Date to end backup ⑧ Backup Screen① from Date 2003 Date to start backup Cancel = Stop2BACKUP from Alarm Event List Search & Play of Back UP Backup image search and replayScsi Erase Scsi HDD Recording Deletion Mode Setup ReferenceIV. Record ② Record Stop ① Current Image Record 1Basic RecordBasic Record Release of Alarm Record Record Lock Alarm RecordRecord in Alarm Occurrence Record Lock4Reservation Record Reservation Record SetupReservation Record Cancel 1Retrieval Menu View ① CLOCK/DISPLAY Mode Setup ➂ Alarm Event Search② Record Event Search ➃ Power Event List Retrieval Menu EnterRetrieval by Date and Time Recorded Data List View Alarm Record Retrieval Power On/Off Status List View 0000526Basic Playback View by Field 7Various Screen View Using JOG/SHUTTLEPlay in Various Speed VI. Others HDD BackupProduct Standards Appearance Drawing VII. Appendices 1Check Points before Call Service Center Trouble Check PointsQuestion Answer AB68-00377A
Related manuals
Manual 45 pages 53.72 Kb