Oreck XL2000RS How to Replace a Worn Belt, Stuffing or Blockage, Retainer Spring, Intake Opening

Page 6

E N G L I S H

How to Replace a Worn Belt

WARNING: Unplug cord from electrical outlet before servicing.

Remove the replacement belt from the storage channel.

Stuffing or Blockage

Under certain conditions it is possible to stuff or block the intake tube and the lower tube assembly. If your vacuum cleaner does not pick up properly, or makes unusual noise and the outer bag does not fluff up or balloon open, follow the following steps:

WARNING: Unplug cord from electrical outlet before servicing.

Remove the door by removing the hold down screw located on side of power head.

Slide the door forward by prying open with a screwdriver or coin.

Remove the belt from the brush roll pulley and the motor drive shaft.

Loop the new belt over the motor drive shaft. Place the opposite end of the belt on the brush roll pulley.

Rotate the brush roll three

(3) complete revolutions to ensure that no part of the belt is overhanging the end of the motor drive shaft.

A

Intake Opening

B

Intake Opening

Retainer

Spring

C

Fan

Housing

O-ring

D

1.Check for blockage at the mouth of the intake opening. See illustration A. If there is blockage, remove it with long-nose pliers, a screwdriver or coat hanger. If you can not reach the blockage, remove baseplate. See illustration B.

2.If the blockage is not at the base, remove lower tube. See illustration C. Unhook retainer spring, releasing bottom of bag. Twist lower collar counterclockwise to slide up. Pull tube out of base. Check for blockage. If blockage is in the tube, remove with a coat hanger.

3.If tube is not blocked, look into fan housing. See illus- tration D. Remove debris with long-nose pliers, a screwdriver or coat hanger.

4.To reassemble, check O-ring on tube, and replace if damaged. Vacuum will not operate properly without the tube O-ring. Slide O-ring to approximately 2" from base of tube. Replace tube by first lining up slot at base of tube with inner tab inside fan housing. Then reinsert tube and push down until the tube is seated. Make sure O-ring is in place against fan housing opening. Replace and tighten collar until collar locking tabs are locked in place. See illustration E. Make sure collar is not cross threaded on housing.

Replace the door by sliding it into the groove at the bottom of the housing. Replace the hold down screw.

E

6

Image 6
Contents XL2000HH XL2000RH XL2000RS Table of Contents Maintenance Customer ServiceAccessories Sold Separately Warranty Troubleshooting GuideAssembly Operating InstructionsTo Replace Filter Dust Bag Lip a of connectorInstalled Hook bottom of bag collarStuffing or Blockage How to Replace a Worn BeltRemove the replacement belt from the storage channel Retainer SpringTo Adjust or Replace Brush Table des matières Entretien et service La clientèleAccessoires Vendu Séparément CommercialGarantie Commercial Hospitality 1-888-23-ORECK Canada 1-866-74-ORECKRessort de retenue Barre de tension du sac Guide de dépannageAssemblage Fermeture à glissièreMode d’emploi Remplacement du sac à poussières filtrant Remplacement d’une Courroie uséeSystème de filtre hypoallergique Celoc Tablette Oreck Fresh Air Blocage ou bourrageUtilisation d’une Instructions de mise à La terreRéglage ou remplacement Du balai Accesorios Vendido por separado IndiceMantenimiento y servicio Clientes Canada 1-888-67-ORECKGuía para identificación De problemas GarantíaEnsamblaje Para reemplazar laBolsa para polvo de filtro Instrucciones de operación Cómo reemplazar una Correa desgastada Para ajustar o reemplazar El cepilloGire y haga corre- sponder los ensamblajes de los cojinetes Resorte Relleno o bloqueoUso de una tableta Anillo Bastidor Tórico del ventilador