13 Finishing

A. Finishing Templates

Two side finishing templates and one top finishing template are supplied with the appliance. They are fastened to the top surround.

INSIDE FIT Method: The finishing template pieces are required for installations that require more than one inch thick finishing materials to be installed over the face of the factory-supplied 1/2 inch non-combustible board. Refer to section 13.E for more information.

OVERLAP Method: The supplied templates are not required for finishing materials less than one inch thick. The required decorative front will overlap finish materials less than one inch thick. Refer to section 13.E for more information.

Note: For Arch Door applications with finish material greater than one inch thick, an Arch Template Kit is available. Contact your dealer to order the arch template kit.

Template installation instruction

1.Determine if the required door options is a inoperable (fixed style) or operable (cabinet style). Doors denoted with an FS are inoperable. Doors denoted with an CS are operable. Refer to Section 13.E for door information.

2.Bend the left and right side templates for the appropriate door type using Figure 13.2 as a reference.

3.Locate the four threaded inserts on the inside edge of the fireplace and secure the side templates with the Phillips screws provided. See Figure 13.3.

4.Bend the top template as shown in Figure 13.1 and secure with the two screws provided. The bend will have two opposing 90 degree bends, similar to the bends on the side templates.

5.Remove all template components once finishing materials are secured.

3/4 IN.

1-1/2 IN.

INOPERABLE OPERABLE

DOORSDOORS

Figure 13.2 Left and Right Side Finishing Template Bends

TOP FINISHING

TEMPLATE

SIDE FINISHING

TEMPLATES

Figure 13.3 Top and Side Finishing Template Locations

Note: A thin layer of mortar may be applied over the visible non-combustible board between finishing material and the fireplace opening.

1-1/4 IN.

TAB

 

INOPERABLE DOORS - BEND DOWN

 

OPERABLE DOORS - DO NOT BEND DOWN

Figure 13.1 Top Finishing Template Bend

Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12

47

Image 47
Contents HOT Surfaces ModelsWhat to do if you smell gas Do DiscardnotHomeowner Reference Information CongratulationsUser Guide Table of ContentsReference Materials Appliance SetupTroubleshooting Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsYour Fireplace Gas Fireplace SafetyOperating Instructions User Guide Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches IPI Battery Tray/Battery InstallationBefore Lighting Fireplace Module ResetNine Hour Safety Shutdown Feature Control Module OperationGAS Valve Lighting Instructions IPIFinal inspection by What to do if YOU Smell GASAfter Fireplace is Lit Frequently Asked QuestionsIssue Solutions Remote Control Optional Maintenance and ServiceMaintenance Tasks-Homeowner Glass Cleaning Exterior of Installed Glass OnlyLogs Maintenance Tasks-Qualified Service TechnicianGlass Cleaning Exterior and Interior of Installed Glass Gasket Seal and Glass Assembly InspectionIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed HEIR42 Framing and ClearancesSelecting Appliance Location HEIR36Clearances Minimum Framing DimensionsConstructing the Appliance Chase Non-Combustible Mantel Legs or Wall Projections Mantel and Wall ProjectionsNon-Combustible Zone Combustible Mantel Legs or Wall ProjectionsCombustible Mantel Allowance HEIR36, HEIR42 NON-COMBUSTIBLE Material HEIR50 Fireplace OpeningModel Hearth ExtensionVent Termination Minimum Clearances Termination LocationsCovered Alcove Applications Clearance above electrical serviceVent Information and Diagrams HEIR36 NG/LP, HEIR42 NG/LP HEIR50 NG/LP Top Vent Horizontal TerminationOne Elbow H1+ H2 Two ElbowsHEIR36 NG/LP, HEIR42 NG/LP, HEIR50 NG/LP Top Vent Horizontal Termination Three ElbowsFlue Restrictor Elbows Top Vent Vertical TerminationHt Max Top Vent Vertical Termination Three ElbowsHEIR42 PVK-80 and PVI-SLP InformationPVI-SLP HEIR36Non-Combustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingPipe DVP Install the Ceiling FirestopVaulted Ceiling Installation Install Attic Insulation ShieldInstalling the Optional Heat-ZoneGas Kit Flat Ceiling InstallationVent Preparation Appliance PreparationSide Nailing Tab in Shipping Position Securing and Leveling the ApplianceInstalling Non-Combustible Facing Material Installing Non-combustible Facing MaterialAssemble Pipe Sections Installing Vent Pipe DVP PipeAttach Vent to the Firebox Assembly Assemble Vent SectionsDisassemble Vent Sections Secure the Vent SectionsAssemble and Install Storm Collar Install Metal Roof FlashingHeat Shield Requirements for Horizontal Termination Install Vertical Termination CapInstall Horizontal Termination Cap Gas Connection Gas InformationFuel Conversion Gas PressureElectrical Information Wiring RequirementsIntelliFire PlusTM Ignition System Wiring Optional Accessories RequirementsAccess Through Left Column Access Through Firebox Electrical Service and Repair Junction Box InstallationFinishing Templates Template installation instructionFinishing Finishing Template Bends Inoperable Fixed Doors Splatter GuardNon-Combustible Zone 10 Combustible Mantel Allowance HEIR36, HEIR42 Combustible Mantel ProjectionsModel HEIR36 Facing MaterialOperable Doors Dimension Inoperable Operable DoorDoors ArchAppliance Setup LOG#4 Install the Log Assembly Log Set Assembly LOGS-HEIR36LOG Placement Tabs LOG Placement Slot Notch for Models HEIR36H, HEIR36SContacts Back Burner Grate NotchLOG Contacts Notch Rests On Burner Grate Tine HEIR42 only Burned Edge PortionHEIR42 Shown Burned Portion Edge of LOG Used For Positioning For LOG #5Burned Portion LOG does not 2CONTACT Grate TineLOG Contacts Grate Tine Log Set Assembly LOGS-HEIR50 Models HEIR50T, HEIR50HBurned Edge LOG Contacts Side Refractory LOG Contacts Grate Tine Approximately HEIR36 HEIR42 HEIR50 TOP Retaining Rail Notch Glass Frame Notch Full Open Air Shutter SettingAir Shutter Settings Flame AppearanceIntelliFire Plus Ignition System TroubleshootingSymptom Possible Cause Corrective Action Troubleshooting Reference Materials Appliance Dimension Diagram1905 DVP-AS2 Vent Components DiagramsDVP-TRAP DVP-TRAP1 DVP-TRAP2 DVP-TRAPK1 DVP-TRAPK2COOL-ADD RF6M RF12MBEK DVP-BEK2 DVP-TRAPFLSLP-LPC Optional Wire HarnessDescription Part Number Description Comments Part Number Service PartsLog Set Assembly At DepotDescription Comments Part Number #19 Traditional Refractory #20 Herringbone RefractoryStocked HEIR42T, HEIR42H HEIR42T, HEIR42H HEIR50T, HEIR50H Log Set Assembly#20 Traditional Refractory #21 Herringbone Refractory HEIR36, HEIR42, HEIR50 #11 Valve AssemblyMYSTIC-EMBERS Contact Information

HEIR50H, HEIR36T, HEIR36H, HEIR50T, HEIR42T specifications

The Heatiator range of heating appliances, including the HEIR36T, HEIR50T, HEIR42H, HEIR42T, and HEIR50H, represents a blend of cutting-edge technology and stylish design, tailored to meet various heating needs in residential spaces. Each model exhibits unique features, yet shares a commitment to efficiency and user-friendliness.

Starting with the HEIR36T, this model is compact yet powerful, making it ideal for smaller living areas. It boasts an efficient heating system that utilizes advanced ceramic heating elements, ensuring rapid warmth. The sleek design is complemented by a digital control panel, allowing users to easily adjust settings for optimal comfort.

In contrast, the HEIR50T caters to larger rooms, offering increased power and a higher heat output. Its robust construction is designed for durability, while energy-efficient technology minimizes operational costs. The HEIR50T comes equipped with a programmable thermostat, enabling users to set heating schedules to align with their lifestyle.

The HEIR42H stands out with its hybrid heating capability, combining traditional radiant heat with modern convection elements. This dual functionality allows for faster and more even heat distribution throughout the space. The HEIR42H is particularly popular for its versatility, suitable for use in various environments from homes to commercial spaces.

The HEIR42T model shares many of the benefits of the HEIR42H but focuses on a sleek, slim-line design that doesn’t compromise on performance. Ideal for minimalistic interiors, it offers the same advanced heating technology, ensuring efficient warmth without taking up excess space.

Lastly, the HEIR50H is designed for heavy-duty performance, making it the perfect choice for larger areas that require substantial heating power. It features enhanced insulation and expanded heating elements, ensuring that even the coldest rooms achieve a comfortable temperature quickly.

In summary, the Heatiator HEIR series exemplifies innovation in home heating solutions. With various models to choose from, customers can select the unit that best suits their space requirements while benefiting from technologies designed for efficiency and comfort. The digital controls, programmable settings, and modern designs make these heaters both functional and aesthetically pleasing, reinforcing Heatiator's commitment to quality and user satisfaction.