Heatiator HEIR36T, HEIR42H, HEIR42T Optional Wire Harness, Description Part Number, Slp-Lpc

Page 70

B. Vent Components Diagrams (continued)

12 in.

305 mm

 

9 in.

2-3/4 in.

(229 mm)

 

(70 mm)

 

 

11-1/2 in.

 

(292 mm)

 

12-1/4 in.

 

(311 mm)

 

16 in.

 

(406 mm)

12-1/2 in. (318 mm)

7-1/4 in.

(184 mm)

12-1/2 in.

(318 mm)

5-1/4 in.

(133 mm)

DVP-TVHW

VerticalTermination Cap (Highwind)

PVK-80

(Approved for HEIR36, HEIR42, HEIR50)

 

13-5/8 IN.

EFFECTIVE LENGTH

346 mm

32 IN. (813 mm) MIN.

 

35 IN. (889 mm) MAX.

 

12-1/2 IN.

318 mm

20-3/4 IN.

527 mm

(Approved for HEIR36 and HEIR42 only)

PVI-SLP

Power Vent Inline

Optional Wire Harness

DESCRIPTION

PART NUMBER

10 ft. PV Wire Harness

PVI-WH10

20 ft. PV Wire Harness

PVI-WH20

40 ft. PV Wire Harness

PVI-WH40

60 ft. PV Wire Harness

PVI-WH60

80 ft. PV Wire Harness

PVI-WH80

100 ft. PV Wire Harness

PVI-WH100

Note: Wire harnesses required to power the PVI-SLP connect to the appliance and are ordered separately from PVI-SLP. Contact your dealer to order.

16 IN.

406 mm

4-1/2 IN.

114 mm

9-3/16 IN.

(233 mm)

15IN.

(381 mm)

13-5/8 IN.

(346 mm)

16-11/16 IN.

424 mm

16-11/16 IN.

(424 mm)

12-1/2 IN. (318 mm)

SLP-LPC

SLP Low Profile Cap

Figure 16.6 Vent Components

70

Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12

Image 70
Contents Do Discardnot ModelsWhat to do if you smell gas HOT SurfacesCongratulations Homeowner Reference InformationTable of Contents User GuideTroubleshooting Appliance SetupReference Materials Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsOperating Instructions User Guide Gas Fireplace SafetyYour Fireplace IPI Battery Tray/Battery Installation Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceControl Module Operation Module ResetNine Hour Safety Shutdown Feature Before Lighting FireplaceWhat to do if YOU Smell GAS Lighting Instructions IPIFinal inspection by GAS ValveIssue Solutions Frequently Asked QuestionsAfter Fireplace is Lit Glass Cleaning Exterior of Installed Glass Only Maintenance and ServiceMaintenance Tasks-Homeowner Remote Control OptionalGasket Seal and Glass Assembly Inspection Maintenance Tasks-Qualified Service TechnicianGlass Cleaning Exterior and Interior of Installed Glass LogsBurner Ignition and Operation IPI Pilot Flame PatternsGetting Started Typical Appliance SystemTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components HEIR36 Framing and ClearancesSelecting Appliance Location HEIR42Constructing the Appliance Chase Minimum Framing DimensionsClearances Combustible Mantel Legs or Wall Projections Mantel and Wall ProjectionsNon-Combustible Zone Non-Combustible Mantel Legs or Wall ProjectionsNON-COMBUSTIBLE Material HEIR50 Fireplace Opening Combustible Mantel Allowance HEIR36, HEIR42Hearth Extension ModelTermination Locations Vent Termination Minimum ClearancesClearance above electrical service Covered Alcove ApplicationsVent Information and Diagrams One Elbow Top Vent Horizontal TerminationHEIR36 NG/LP, HEIR42 NG/LP HEIR50 NG/LP Two Elbows H1+ H2Top Vent Horizontal Termination Three Elbows HEIR36 NG/LP, HEIR42 NG/LP, HEIR50 NG/LPFlue Restrictor Top Vent Vertical Termination ElbowsTop Vent Vertical Termination Three Elbows Ht MaxHEIR36 PVK-80 and PVI-SLP InformationPVI-SLP HEIR42Wall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Non-Combustible Wall PenetrationInstall the Ceiling Firestop Pipe DVPFlat Ceiling Installation Install Attic Insulation ShieldInstalling the Optional Heat-ZoneGas Kit Vaulted Ceiling InstallationAppliance Preparation Vent PreparationSecuring and Leveling the Appliance Side Nailing Tab in Shipping PositionInstalling Non-combustible Facing Material Installing Non-Combustible Facing MaterialAssemble Vent Sections Installing Vent Pipe DVP PipeAttach Vent to the Firebox Assembly Assemble Pipe SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Metal Roof Flashing Assemble and Install Storm CollarInstall Horizontal Termination Cap Install Vertical Termination CapHeat Shield Requirements for Horizontal Termination Gas Pressure Gas InformationFuel Conversion Gas ConnectionOptional Accessories Requirements Wiring RequirementsIntelliFire PlusTM Ignition System Wiring Electrical InformationElectrical Service and Repair Junction Box Installation Access Through Left Column Access Through FireboxFinishing Template installation instructionFinishing Templates Splatter Guard Finishing Template Bends Inoperable Fixed DoorsNon-Combustible Zone Combustible Mantel Projections 10 Combustible Mantel Allowance HEIR36, HEIR42Facing Material Model HEIR36Arch Dimension Inoperable Operable DoorDoors Operable DoorsAppliance Setup Models HEIR36H, HEIR36S Install the Log Assembly Log Set Assembly LOGS-HEIR36LOG Placement Tabs LOG Placement Slot Notch for LOG#4Burned Edge Portion Burner Grate NotchLOG Contacts Notch Rests On Burner Grate Tine HEIR42 only Contacts BackLOG does not 2CONTACT Grate Tine Burned Portion Edge of LOG Used For Positioning For LOG #5Burned Portion HEIR42 ShownLog Set Assembly LOGS-HEIR50 Models HEIR50T, HEIR50H LOG Contacts Grate TineBurned Edge LOG Contacts Side Refractory LOG Contacts Grate Tine Approximately HEIR36 HEIR42 HEIR50 TOP Retaining Rail Notch Glass Frame Notch Flame Appearance Air Shutter SettingAir Shutter Settings Full OpenSymptom Possible Cause Corrective Action TroubleshootingIntelliFire Plus Ignition System Troubleshooting Appliance Dimension Diagram Reference Materials1905 Vent Components Diagrams DVP-AS2DVP-TRAP1 DVP-TRAP2 DVP-TRAPK1 DVP-TRAPK2 DVP-TRAPDVP-TRAPFL RF6M RF12MBEK DVP-BEK2 COOL-ADDDescription Part Number Optional Wire HarnessSLP-LPC At Depot Service PartsLog Set Assembly Description Comments Part NumberStocked #19 Traditional Refractory #20 Herringbone RefractoryDescription Comments Part Number HEIR42T, HEIR42H HEIR42T, HEIR42H Log Set Assembly HEIR50T, HEIR50H#20 Traditional Refractory #21 Herringbone Refractory #11 Valve Assembly HEIR36, HEIR42, HEIR50MYSTIC-EMBERS Contact Information

HEIR50H, HEIR36T, HEIR36H, HEIR50T, HEIR42T specifications

The Heatiator range of heating appliances, including the HEIR36T, HEIR50T, HEIR42H, HEIR42T, and HEIR50H, represents a blend of cutting-edge technology and stylish design, tailored to meet various heating needs in residential spaces. Each model exhibits unique features, yet shares a commitment to efficiency and user-friendliness.

Starting with the HEIR36T, this model is compact yet powerful, making it ideal for smaller living areas. It boasts an efficient heating system that utilizes advanced ceramic heating elements, ensuring rapid warmth. The sleek design is complemented by a digital control panel, allowing users to easily adjust settings for optimal comfort.

In contrast, the HEIR50T caters to larger rooms, offering increased power and a higher heat output. Its robust construction is designed for durability, while energy-efficient technology minimizes operational costs. The HEIR50T comes equipped with a programmable thermostat, enabling users to set heating schedules to align with their lifestyle.

The HEIR42H stands out with its hybrid heating capability, combining traditional radiant heat with modern convection elements. This dual functionality allows for faster and more even heat distribution throughout the space. The HEIR42H is particularly popular for its versatility, suitable for use in various environments from homes to commercial spaces.

The HEIR42T model shares many of the benefits of the HEIR42H but focuses on a sleek, slim-line design that doesn’t compromise on performance. Ideal for minimalistic interiors, it offers the same advanced heating technology, ensuring efficient warmth without taking up excess space.

Lastly, the HEIR50H is designed for heavy-duty performance, making it the perfect choice for larger areas that require substantial heating power. It features enhanced insulation and expanded heating elements, ensuring that even the coldest rooms achieve a comfortable temperature quickly.

In summary, the Heatiator HEIR series exemplifies innovation in home heating solutions. With various models to choose from, customers can select the unit that best suits their space requirements while benefiting from technologies designed for efficiency and comfort. The digital controls, programmable settings, and modern designs make these heaters both functional and aesthetically pleasing, reinforcing Heatiator's commitment to quality and user satisfaction.