Heath Zenith SL-4190 Series manual Testing, Turn on the circuit breaker and light switch

Page 6

TESTING

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute warm up pe- riod before it will detect motion.When first turned on, wait 1 1/2 minutes.

Note: Meets the ENERGY STAR® guidelines when DualBrite® function is off.

Switch the on-time to TEST position and DualBrite® switch to the OFF position.

TEST 1 5 10 MIN

OFF 3 6 DUSK TO

ON-TIME

HOUR DAWN

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air condition- ers. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

The detector is less sensitive to motion di- rectly towards it and more sensitive to across motion.

MotionMotion

Sensor

Least Sensitive

Most Sensitive

Walk through the coverage area noting where you are when the lights turn on.

If you need to change the sensitivity, temporarily remove the fixture and make the adjustment. Too much sensitivity may increase false triggering.

Set the amount of TIME you want the light to stay on after motion is detected. (1, 5, or 10 minutes).

Set the amount of time after dusk you want the lights on accent level.

6 ft.

180°

 

(1.8 m)

 

30ft.

(9.1 m)

Maximum Range

Maximum

 

Coverage Angle

595-5628-08

Image 6
Contents Operation FeaturesSome codes require installation by a qualified electrician RequirementsInstallation Mode Switching SummaryDualBrite Dimmer Control Wiring Two Motion Lights Recommended Grounding MethodOptional Wiring Wiring DiagramComplete the Installation Model 4193 Glass InstallationTesting Turn on the circuit breaker and light switchAvoid aiming the control at Specifications Troubleshooting GuideTechnical Service No Service Parts Available for this ProductFuncionamiento CaracterísticasRequisitos Instalacion Luz de Adorno DualBriteADVERTENCIADesconecte la ener- gía en el disyuntor Cableado Diagrama de Cableado Conexion AlternaComplete LA Instalacion Instalación del vidrio del Modelo 4193Prueba Prenda el cortacircuitos y el interruptor de luzEvite apuntar el control hacia Especificaciones Guia DE Investigacion DE AveriasServicio Técnico No hay piezas de servicio disponibles para este productoFonctionnement CaractéristiquesExigences Résumé du mode de commutation Minuterie DualBriteMDCâblage Câblage Facultatif Complétez Linstallation Installation des panneaux de Verre de modèleEssais Le moins sensible Le plus sensibleFiche Technique Guide DE DépannageService Technique Aucune pièce de rechange n’est disponible pour ce produit