TEST AND ADJUSTMENT
❒Turn on the circuit breaker and light switch.
❒Set the
NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes.
ON-TIME
10 TEST
❒Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.
❒Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the cover- age area. Keep the sensor at least 1" (2.5 cm) away from the lamps.
❒Secure the sensor head by tightening the clamp screw. Do not overtighten the screw.
❒Set the
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
Bottom of Sensor
Avoid aiming the control at:
•Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
•Areas where pets or traffic may trigger the control.
•Nearby large,
180°
8 ft.
(2.4 m)
50 ft.
(15.2 m)
Maximum Range | Maximum |
| Coverage Angle |
The detector is most sensitive to motion across its field of view.
Warning - Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).
SPECIFICATIONS
Range . . . . . . . Up to 50 ft. (15.2 m) [varies with surrounding temperature].
Sensing Angle. . . . Up to 180°
Electrical Load. . . . Up to 300 Watt Maximum In- candescent [Up to 150 Watt maximum each lamp holder.]
Power Requirements. 120 VAC, 60 Hz
Operating Modes. . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . 10 minutes Range . . . . . . . Adjustable
HeathCo LLC reserves the right to discontinue prod- ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
Motion
Motion
| Sensor |
Least Sensitive | Most Sensitive |