Heath Zenith manual Operation, Model BL-1800, Features, Requirements, Mode Switching Summary

Page 1

Motion Sensor Light Control

As an ENERGY STAR® Partner, Heath®/Zenith has determined that this product meets the EN- ERGY STAR® guidelines for energy efficiency. This product is ENERGY STAR® compliant when used with 120 Watt bulbs.

Model BL-1800

Features

Turns on lighting when motion is detected.

Automatically turns lighting off.

Photocell keeps the lighting off during daylight hours.

This package includes:

OPERATION

Mode:

On-Time

Works: Day

Night

Test

5 Seconds

x

x

Auto

10 Min

 

x

Manual

Until Dawn*

 

x

* resets to Auto Mode at dawn.

Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate.

TEST

Put the ON-TIME switch on the bottom

ON-TIME

 

of the sensor in the TEST position.

 

 

 

 

 

 

 

 

 

 

 

 

10

TEST

 

 

 

 

 

 

AUTO

 

 

 

 

 

 

 

 

 

 

Put the ON-TIME switch in the 10

ON-TIME

minute position.

 

 

 

 

 

 

 

 

 

 

 

 

10

TEST

 

 

 

 

 

 

MANUAL MODE

Lamp Holders

Cover

 

Plate

4 Mounting

 

Screws (2 sizes)

Sensor

Gasket

Manual mode only works at night because daylight returns the sensor to AUTO.

Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.

Manual mode works only with the ON- TIME switch in the 10 position.

1 Second OFF

then...

Light Control

2 Wire

Connectors

 

... back on.

Requirements

The light control requires 120-volts AC.

If you want to use Manual Mode, the control must be wired through a switch.

Some codes require installation by a qualified electrician.

This product is intended for use with a junction box marked for use in wet locations.

The backplate has knockouts so the sensor can be mounted on most junction boxes.

In some applications a universal adaptor plate may be needed. Adaptors are available at home centers and electrical supply stores.

Mode Switching Summary

 

TEST

 

 

 

 

Move ON-TIME Switch to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 minutes

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

 

Flip light switch off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for one second then

 

 

 

 

 

 

 

 

back on*

MANUAL MODE

 

 

 

 

 

 

 

*If you get confused while switching modes, turn the power off for one minute, then back on. After the cali- bration time the control will be in the AUTO mode.

© 2007 HeathCo LLC

598-1321-01

Image 1
Contents Mode Switching Summary FeaturesOperation Model BL-1800Wire the Light Control InstallationEave Mount Wall Mount Black to White to Black WhiteGasketSpecifications Test and AdjustmentTurn on the circuit breaker and light switch Aim Sensor Down for Short Coverage Higher for LongNo Service Parts Available for this Product Troubleshooting GuideSymptom Possible Cause Modelo BL-1800 FuncionamientoCaracterísticas RequisitosMontaje en pared Montaje en alero InstalacionBlanco a Negro a Especificaciones Prueba Y AjustePrenda el cortacircuitos y el interruptor de luz Parte de abajo del detector Evite apuntar el control haciaServicio Técnico Guia DE Investigacion DE AveriasNo hay piezas de servicio disponibles para este producto Garantía Limitada a 2 AñosFonctionnement Résumé du mode de commutationModèle BL-1800 CaractéristiquesBlanc Montage sous Montage mural Avant-toitGarniture Blanc Noir De jointFiche Technique Essais ET RéglagesBas du détecteur Éviter de pointer l’appareilGuide DE Dépannage Service TechniqueAucune pièce de rechange n’est disponible pour ce produit Symptôme Cause Possible