Heath Zenith 5318 manual DualBrite Motion Sensor Light Control, Operation, Features, Requirements

Page 1

DualBrite® Motion Sensor Light Control

Models 5312 and 5318

Meets the ENERGY STAR® guidelines when DualBrite® function is off and ON-TIME is 1 or 5 minutes and when used with 120 W Max bulbs.

Features

Turns on lighting when motion is detected.

Automatically turns lighting off.

DualBrite® Timer.

Photocell keeps the lighting off during daylight hours.

LED indicates motion was sensed (day or night).

This package includes:

Bulb

 

 

Holders

 

Rubber Plug

 

 

Plastic Hanger

Cover

 

 

Plate

 

Sensor

 

 

 

Light Control

2 Wire

 

Connectors

 

 

Requirements

The light control requires 120-volts AC.

If you want to use Manual Mode, the control must be wired through a switch.

Some codes require installation by a qualified electrician.

This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.

OPERATION

Mode:

On-Time

Works: Day

Night

Test

5 Seconds

x

x

Auto

1, 5, or 20 Min

 

x

Manual

To Dawn*

 

x

Accent

3, 6 Hr, to Dawn

 

x

* resets to Auto Mode at dawn.

Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate.

TEST

Put ON-TIME switch

ON-TIME

DualBrite®

on the sensor bottom

 

 

 

 

 

 

 

 

 

 

to TEST and the Dual-

 

 

 

 

 

 

 

 

 

 

TEST 1 5 20

Off 3 6 Dusk to

Brite® switch OFF.

 

 

 

 

 

 

 

 

Dawn

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTO

Put the ON-TIME switch in the 1, 5,

ON-TIME

 

 

 

 

 

 

or 20 minute position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEST 1 5 20

MANUAL MODE

 

 

 

 

 

 

Mounting Bolt

Mounting Strap

 

Gasket

 

6 Screws

2 Shells*

(3 sizes included)

* Model SL-5318 only

Manual mode only works at night because daylight returns the sensor to AUTO.

Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.

Manual mode works only with the ON-TIME switch in the 1, 5, or 20 position.

1 Second OFF

then...

... back on.

© 2007 HeathCo LLC

595-5731-07

Image 1
Contents DualBrite Motion Sensor Light Control FeaturesOperation RequirementsMode Switching Summary InstallationDualBrite Timer Wall MountMounting Black to White to Strap Junction box ground wire to green ground screw on fixtureTurn on the circuit breaker and light switch Test and AdjustmentBottom of Sensor Avoid aiming the control atTroubleshooting Guide SpecificationsNo Service Parts Available for this Product Technical ServiceFuncionamiento Control de luz y detector de movimiento DualBriteCaracterísticas RequisitosResumen de las modalidades del interruptor InstalacionLuz de Adorno DualBrite Montaje en pared Montaje en aleroLámina de Negro a Blanco a Montaje Advertencia Desconecte la energía en el disyuntorParte de abajo del detector Prueba Y AjustePrenda el cortacircuitos y el interruptor de luz Evite apuntar el control haciaGuia DE Investigacion DE Averias EspecificacionesNo hay piezas de servicio disponibles para este producto Servicio TécnicoFonctionnement Commande d’éclairage DualBriteMD à détecteur de mouvementCaractéristiques ExigencesMinuterie DualBriteMD Résumé du mode de commutationMontage sous Montage mural Avant-toitNoir Câblage de la Commande D’éclairageBas du détecteur Essais ET RéglagesÉviter de pointer l’appareil Guide DE Dépannage Fiche TechniqueAucune pièce de rechange n’est disponible pour ce produit Service Technique595-5731-07 Nº de modelo / N de modèle