Desa FSBVBPC, FSBVBNC installation manual Pressure Testing Burner System Gas Connections

Page 15

OWNER’S MANUAL

STOVE AND B-VENT BURNER SYSTEM INSTALLATION

Continued

4.Check all joints of gas supply piping system. Apply commercial leak test so- lution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

5.Reconnect burner system and equip- ment shutoff valve to gas supply. Check reconnected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 33).

2.Pressurize supply piping system by ei- ther opening propane/LP supply tank valve for propane/LP gas burner sys- tem or opening main gas valve located on or near gas meter for natural gas burner system, or using compressed air.

3.Check all joints from propane/LP sup- ply tank or gas meter to equipment shutoff valve (see Figure 34 for pro- pane/LP or Figure 35 for natural). Ap- ply commercial leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Burner System Gas Connections

1.Open equipment shutoff valve (see Fig- ure 33).

2.Open propane/LP supply tank valve for propane/LP burner system or main gas valve located on or near gas meter for natural gas burner system.

3.Make sure control knob of burner sys- tem is in the OFF position.

4.Check all joints from equipment shutoff valve to thermostat gas valve (see Fig- ure 34 for propane/LP or Figure 35 for natural). Apply commercial leak test so- lution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

5.Light burner system (see Lighting In- structions, page 19). Check all other in- ternal joints for leaks.

6.Turn off burner system (see To Turn Off Gas to Appliance, page 19).

Open

Equipment

Shutoff

Valve

Closed

Figure 33 - Equipment Shutoff Valve

Equipment

100 lb. (Min.)

Shutoff

Propane/LP

Valve

Supply Tank

Gas Valve

 

Figure 34 - Checking Gas Joints for Propane/LP Gas Burner System

Equipment

Shutoff Valve

Gas Meter

Gas Valve

Figure 35 - Checking Gas Joints for Natural Gas Burner System

Continued

107600

15

For more information, visit www.desatech.com

Image 15
Contents OWNER’S Operation and Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Cast Iron Stove and Burner System Safety InformationOperation Product FeaturesProduct Identification Local CodesLocation and Space Requirements PRE-INSTALLATION PreparationStove Body Assembly Cast Iron Stove and B-VENT Burner System AssemblyAttaching Stove Legs Installing Gasket, Connector Plate, and Top Grates Installing B-VENT Burner System Into Stove BodyTOP View Installing Optional Blower AccessoryVenting Installation Installing Rear CoverInstallation Precautions Type B-VENT Installation Listed B-0 or Greater Installation of Listed B-1 VentInstalling Vent System in a Chase Checking Vent CapacityChimneys Flue GAS Spillage Troubleshooting Venting ProblemsHigh Altitude Installation Relining SystemsStove and B-VENT Burner System Installation Installing GAS Piping to Fireplace LocationCheck GAS Type Connecting Stove and Burner System to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Close equipment shutoff valve see Figure Pressure Testing Burner System Gas ConnectionsInstalling Optional Wall Mounted Thermostat GWMT1, GWMS2 Installing Optional Wall Mounted Switch GWMS2Installing Remote Receiver Installing 9-Volt Battery in Hand- Held Remote Control UnitREMOVING/REPLACING Glass Door Installing Log No Installing LOGS, Lava ROCK, and Glowing EmbersLighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating Stove with B-VENT Burner SystemGhrcta Series Operation Optional RemoteThermostat Control Operation Ghrc Series OperationOperating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning and MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Service Hints Replacement PartsTechnical Service Wiring DiagramAccessories SpecificationsFsbvbnc Fsbvbpc Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListFMI Stove PFC Series KEY Part Description QTY International Warranty Information