Desa FSBVBPC, FSBVBNC installation manual Troubleshooting, Observed Problem Possible Cause

Page 23

OWNER’S MANUAL

TROUBLESHOOTING

Note: For additional help, visit DESA International’s technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean pilot. This can damage pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at pilot

1.Ignitor electrode not connected to igni- tor cable

2.Ignitor cable pinched or wet

3.Piezo ignitor nut is loose

4.Broken ignitor cable

5.Bad piezo ignitor

6.Ignitor electrode broken

7.Ignitor electrode positioned wrong

1.Reconnect ignitor cable

2.Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry

3.Tighten nut holding piezo ignitor. Nut is located behind the mounting bracket

4.Replace ignitor cable

5.Replace piezo ignitor

6.Replace pilot assembly

7.Replace pilot assembly

When ignitor button is pressed, there is spark at pilot but no ignition

1.Gas supply turned off or equipment shutoff valve closed

2.Control knob not in PILOT position

3.Control knob not pressed in while in PILOT position

4.Air in gas lines when installed

5.Depleted gas supply (propane/LP mod- els only)

6.Pilot is clogged

7.Gas regulator setting is not correct

1.Turn on gas supply or open equipment shutoff valve

2.Turn control knob to PILOT position

3.Press in control knob while in PILOT position

4.Continue holding down control knob. Repeat igniting operation until air is removed

5.Contact local propane/LP gas company

6.Clean pilot (see Cleaning and Mainte- nance, page 22) or replace pilot assembly

7.Replace gas control

Pilot lights but flame goes out when control

1.

Control knob not fully pressed in

1.

Press in control knob fully

knob is released

2.

Control knob not pressed in long enough

2.

After pilot lights, keep control knob

 

 

 

 

pressed in 30 seconds

 

3.

Equipment shutoff valve not fully open

3.

Fully open equipment shutoff valve

 

4.

Control valve damaged

4.

Replace control valve

www.desatech.com

Continued

107600

23

For more information, visit www.desatech.com

Image 23
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Cast Iron Stove and Burner System Safety InformationOperation Product FeaturesProduct Identification Local CodesLocation and Space Requirements PRE-INSTALLATION PreparationStove Body Assembly Cast Iron Stove and B-VENT Burner System AssemblyAttaching Stove Legs Installing Gasket, Connector Plate, and Top Grates Installing B-VENT Burner System Into Stove BodyTOP View Installing Optional Blower AccessoryInstallation Precautions Venting InstallationInstalling Rear Cover Type B-VENT Installation Listed B-0 or Greater Installation of Listed B-1 VentChimneys Installing Vent System in a ChaseChecking Vent Capacity Flue GAS Spillage Troubleshooting Venting ProblemsHigh Altitude Installation Relining SystemsCheck GAS Type Stove and B-VENT Burner System InstallationInstalling GAS Piping to Fireplace Location Checking GAS Connections Connecting Stove and Burner System to GAS SupplyPressure Testing Gas Supply Piping System Close equipment shutoff valve see Figure Pressure Testing Burner System Gas ConnectionsInstalling Optional Wall Mounted Thermostat GWMT1, GWMS2 Installing Optional Wall Mounted Switch GWMS2REMOVING/REPLACING Glass Door Installing Remote ReceiverInstalling 9-Volt Battery in Hand- Held Remote Control Unit Installing Log No Installing LOGS, Lava ROCK, and Glowing EmbersLighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating Stove with B-VENT Burner SystemGhrcta Series Operation Optional RemoteThermostat Control Operation Ghrc Series OperationOperating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning and MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Service Hints Replacement PartsTechnical Service Wiring DiagramAccessories SpecificationsFsbvbnc Fsbvbpc Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListFMI Stove PFC Series KEY Part Description QTY International Warranty Information