INSTALLING OPTIONAL BLOWER ACCESSORY

NOTICE: If installing blower in an existing stove burner system with gas connections, shut off gas sup- ply and disconnect burner sys- tem from gas supply. Contact a qualified service person to do this.

1.Remove 4 hex bolts securing rear cover to back of stove body (see Figure 18).

2.Separate bottom cover from rear cover by loosening the 8 mounting screws (see Figure 18).

3.Align the holes in the top mounting tabs of blower with the holes in wall of rear cover. Using the 4 screws provided, mount blower and tighten screws se- curely (see Figure 19).

4.Attach thermal switch and bracket to inside rear cover wall with two hex head screws provided as shown. After secur- ing bracket to rear cover, carefully bend

along existing bend line on bracket to almost a 90° angle (see Figure 19). This will allow thermal switch to be posi- tioned against stove rear wall and sense temperature when in operating mode.

5.Place speed control on left inside of rear cover and push the plastic control shaft through opening (see Figure 19).

6.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until tight against the side of rear cover. Place control knob provided onto shaft.

7.Place the green ground wire between the bottom hole on the blower assembly and the hex screw and tighten (see Figure 20, page 9).

8.Connect the blue wire to the blower as- sembly and one side of the thermal switch (see Figure 20, page 9).

9.Connect the black wire to the other side of the thermal switch (see Figure 20, page 9).

10.Connect the white wire to the other ter- minal on the blower motor assembly (see Figure 20, page 9). Make sure the thermal switch has been properly in- stalled to fit against back of burner sys- tem after the rear cover assembly has been reinstalled.

11.Make sure all wire connections to termi- nals on blower motor and thermal switch are securely attached and that the screw retaining the green ground wire is tight.

12.Check to make sure that the power cord is completely clear of the blower wheel and that there are no foreign objects in blower wheel.

WARNING: Never touch the blower wheel while in operation.

13.Peel off the backing paper and stick the supplied wiring diagram decal on the inside of rear cover as shown (see Fig- ure 20, page 9).

14.Connect or reconnect gas supply fol- lowing instructions in Connecting Stove and Burner System to Gas Sup- ply, page 14.

Hex Bolts

Stove Body

Rear Cover

Locknut

Mounting

Blower

Control

Screws

Control

Shaft

Hex

Knob

TOP VIEW

 

Bolts

 

 

 

Mounting

 

Speed

Screws

Thermal

Control

 

 

 

Switch

 

 

and

 

 

Bracket

 

Mounting

Mounting

Screws

 

Screws

 

Holes

 

Bottom Cover

 

 

 

Figure 18 - Removing Rear Cover and Bottom Cover from Stove Body

Blower

Mounting

 

 

Assembly

 

Holes

 

 

 

Figure 19 - Blower Assembly, Speed

 

Control, and Thermal Switch Locations

For more information, visit www.desatech.com

8

107600

Image 8
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Safety Information Cast Iron Stove and Burner SystemProduct Features Product IdentificationLocal Codes OperationPRE-INSTALLATION Preparation Location and Space RequirementsCast Iron Stove and B-VENT Burner System Assembly Stove Body AssemblyAttaching Stove Legs Installing B-VENT Burner System Into Stove Body Installing Gasket, Connector Plate, and Top GratesInstalling Optional Blower Accessory TOP ViewInstallation Precautions Venting InstallationInstalling Rear Cover Installation of Listed B-1 Vent Type B-VENT Installation Listed B-0 or GreaterChimneys Installing Vent System in a ChaseChecking Vent Capacity Troubleshooting Venting Problems High Altitude InstallationRelining Systems Flue GAS SpillageCheck GAS Type Stove and B-VENT Burner System InstallationInstalling GAS Piping to Fireplace Location Checking GAS Connections Connecting Stove and Burner System to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Burner System Gas Connections Close equipment shutoff valve see FigureInstalling Optional Wall Mounted Switch GWMS2 Installing Optional Wall Mounted Thermostat GWMT1, GWMS2REMOVING/REPLACING Glass Door Installing Remote ReceiverInstalling 9-Volt Battery in Hand- Held Remote Control Unit Installing LOGS, Lava ROCK, and Glowing Embers Installing Log NoFor Your Safety Read Before Lighting Manual Lighting ProcedureOperating Stove with B-VENT Burner System Lighting InstructionsOptional Remote Thermostat Control OperationGhrc Series Operation Ghrcta Series OperationOperating Optional Blower Accessory Pilot AssemblyInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatCleaning and Maintenance Glass DoorPilot and Burners LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Replacement Parts Technical ServiceWiring Diagram Service HintsSpecifications AccessoriesIllustrated Parts Breakdown Fsbvbnc FsbvbpcParts List KEY Part Number Description QTYFMI Stove PFC Series KEY Part Description QTY Warranty Information International