THERMOSTAT

OPERATING HEATER

Continued

5.Turn control knob counterclockwiseFigure 37 - Control Knob and Ignitor to the PILOT position. Press in control knob for five (5) seconds (see Figure 37).

Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

If control knob does not pop out when re- leased, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, press and re- lease ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety inter- lock system. Wait one (1) minute for sys- tem to reset before lighting pilot again.

8.Turn control knob counterclockwise

Button Location to desired heating level. The burn- ers should light. Set control knob to any heat level between HI and LO.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise Figure 38 - Pilot to the OFF position.

Shutting Off Burners Only (pilot stays lit)

Turn control knob clockwise Manual background to the PI- LOT position.

THERMOSTAT

CONTROL OPERATION

The thermostat control knob can be set to any comfort level between HI and LO. The ther- mostat will gradually modulate the heat out- put and flame height from higher to lower set- tings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

Note: Selecting the HI setting with the control knob will cause the burners to remain fully on, without modulating down in most cases.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Lighting In- structions, pages 22 and 23.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, under Lighting Instructions, column 1.

OFF

Pilot

Ignitor Button

Control Knob

 

Figure 37 - Control Knob and Ignitor

 

Button Location

Ignitor

Pilot Burner

Electrode

Thermocouple

Figure 38 - Pilot

111160-01C

www.desatech.com

23

Image 23
Contents —WHAT TO DO IF YOU SMELL GAS TABLE OF CONTENTS SAFETY INFORMATION Continued SAFETY INFORMATIONPRODUCT IDENTIFICATION UNPACKING PRODUCT FEATURESSAFETY PILOT LOCAL CODESDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION ContinuedFigure 3 - Ventilation Air from Inside Building 5.3or applicable local codesContinued VENTILATION AIRINSTALLATION MINIMUM FIREPLACE CLEARANCE ContinuedFigure 6 - Heat Resistant Material Slate Without Using HoodContinued MANTEL CLEARANCESFigure 10 - Minimum Fireplace When Using HoodContinued FLOOR CLEARANCESINSTALLING HEATER BASE ASSEMBLY Fireplace Floor - Dual Burner Model CONNECTING TO GAS SUPPLYFigure 13 - Attaching Base Assembly to CHECKING GAS CONNECTIONS Propane/LP Gas Models ContinuedFigure 17 - Equipment Shutoff Valve Figure 18 - Checking Gas JointsContinued INSTALLING LOGSdamage or personal injury Figure 24 - Installing Front Log #1 Figure 25 - Installing Middle Log #2Figure 26 - Installing Rear Log #3 Figure 27 - Installing Crossover Log #4Holes Figure 29 - Installing Crossover Log #5Figure 31 - Installing Crossover Log #7 ContinuedFigure 33 - Installing Front Log Back Log Post Base Assembly PostFigure 32 - Installing Back Log AssemblyLIGHTING INSTRUCTIONS MANUALLY-CONTROLLED MODELS FOR YOUR SAFETYOPERATING HEATER READ BEFORE LIGHTINGShutting Off Heater MANUAL LIGHTING PROCEDUREVARIABLE CONTROL OPERATION TO TURN OFF GAS TO APPLIANCELIGHTING INSTRUCTIONS THERMOSTAT-CONTROLLED MODELS FOR YOUR SAFETY1.STOP! Read the safety information, col- umn READ BEFORE LIGHTINGTHERMOSTAT CONTROL OPERATION MANUAL LIGHTING PROCEDUREContinued TO TURN OFF GAS TO APPLIANCEBURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE PILOT FLAME PATTERNBURNER PRIMARY AIR HOLES MAIN BURNERFigure 41 - Injector Holder On Outlet Burner Tube ContinuedLOGS MAIN BURNERREMEDY TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEREMEDY OBSERVED PROBLEMContinued POSSIBLE CAUSEWARNING: If you smell gas •Shut off gas supply Figure 45 - Removing Thermostat Sensing Bulb Assembly and Thermostat Sensing BulbFOR MASONRY AND FACTORY- BUILT METAL FIREPLACE Figure 44 - Adhesive-backedMounting ClipOPTIONAL POSITIONING OF THERMOSTAT SENSING BULB REPLACEMENT PARTSPARTS UNDER WARRANTY PARTS NOT UNDER WARRANTYSINGLE BURNER SEASONAL OAK MODELS SPECIFICATIONSDUAL BURNER SMOKY MOUNTAIN OAK MODELS DUAL BURNER BILTMORE SPLIT OAK MODELSILLUSTRATED PARTS BREAKDOWN PARTS LIST 19 17 21 4 3 2019 11 13 9 6 21 21 5 1 2 10 7 14 8 15 21103008-02 111160-01C 22 1420 24 21 13 15 11 8 23 233 12 6 9 16 10 17 23 18 21 23111340-03 7 12 6 25 16 10 17 23 18 111160-01CPeg positions vary according to model 2 5 22 1420 24 21 13 15 11 8 23 23 9111340-02 111160-01C VARIABLE MANUALLY-CONTROLLEDSEASONAL OAK MODELS Washer Equipment Co PARTS CENTRALPortable Heater Parts Master Parts DistDAMPER CLAMP - GA6080 Not Shown EQUIPMENT SHUTOFF VALVE - GA5010INFORMATION VIDEO - FIREPLACE HOODSerial No. _________________________ KEEP THIS WARRANTYLIMITED WARRANTY Model ____________________________