Desa CGP10R Operating Heater, For Your Safety Read Before Lighting, Lighting Instructions

Page 10
OPERATING

GAS RESIDENTIAL HEATERS

OPERATING

HEATER

FOR YOUR SAFETY

READ BEFORE

LIGHTING

FOR YOUR SAFETY WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information above.

2.Make sure manual shutoff valve is fully open.

3.Turn control knob clockwise LIGHTING to the OFF position.

Piezo Ignitor Button

Control Knob

PILOT

OFF

 

IGNITOR LOW

HIGH

Figure 16 - Control Knob In The OFF Position

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information. If you don’t smell gas, go to the next step.

5.Press in control knob, and turn

counterclockwise TO SELECT to pilot position. Keep control knob pressed for five seconds.

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not light, refer to Trouble Shooting, pages 12 through 14. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match, see Manual Lighting Procedure, page 11.

Ignitor Electrode

Pilot Burner

Thermocouple

Figure 17 - Pilot

7.Keep control knob pressed in for 10 seconds after lighting pilot. After 10 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

TO SELECT

HEATING LEVEL

Manual background WARNING: When running heater, set control knob at LOW or HIGH locked positions. Never set control knob between locked positions. Poor combustion and higher levels of carbon monox- ide may result.

Manual background CAUTION: Do not try to adjust heating levels by using the manual shutoff valve.

1.Slightly press in control knob and

turn counterclockwise Manual background o the LOW or HIGH positions.

IMPORTANT: Release downward pressure while turning control knob. Control knob will lock at the desired position.

10

103548

Image 10
Contents CGP10R OWNER’S OPERATION AND INSTALLATION MANUALINFRARED VENT-FREEPROPANE/LP GAS HEATER CGP10RLGAS RESIDENTIAL HEATERS SAFETY INFORMATIONPRODUCT FEATURES LOCAL CODESUnusually Tight Construction PRODUCT IDENTIFICATIONAIR FOR COMBUSTION AND VENTILATION PROVIDING ADEQUATE VENTILATIONAIR FOR COMBUSTION AND VENTILATION ContinuedGAS RESIDENTIAL HEATERS DETERMINING AIR FLOW FOR HEATER LOCATIONVentilation Air From Inside Building AIR FOR COMBUSTION AND VENTILATIONContinued Ventilation Air From OutdoorsGAS RESIDENTIAL HEATERS INSTALLING TO WALLINSTALLATION ITEMS CHECK GAS TYPEInstalling Bottom Mounting Screw INSTALLING TO WALLInstalling Two Mounting Screws ContinuedGAS RESIDENTIAL HEATERS CONNECTING TO GAS SUPPLYINSTALLING TO WALL ContinuedPRESSURE TESTING HEATER GAS CONNECTIONS CHECKING GAS CONNECTIONSPRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1/2 PSIGLIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTINGOPERATING HEATER TO SELECT HEATING LEVELTO TURN OFF GAS TO APPLIANCE MANUAL LIGHTING PROCEDUREINSPECTING BURNER OPERATING HEATERTROUBLESHOOTING SPECIFICATIONSACCESSORY OBSERVED PROBLEMContinued TROUBLESHOOTINGOBSERVEDPROBLEM POSSIBLE CAUSETROUBLESHOOTING TECHNICAL SERVICESERVICE HINTS OBSERVEDPROBLEMSERVICE PUBLICATIONS CLEANING AND MAINTENANCEREPLACEMENT PARTS PARTS CENTRALS8 4 7 22 25 5 6 ILLUSTRATED PARTS BREAKDOWN CGP10R CGP10RLGAS RESIDENTIAL HEATERS GRH VP11ANUMBER PARTS LIST CGP10R CGP10RLPART DESCRIPTIONGAS RESIDENTIAL HEATERS Page LIMITED WARRANTY WARRANTY INFORMATIONCOMFORT GLOW VENT-FREERESIDENTIAL GAS HEATERS