Ventilation Air From Inside Building

OWNER’S MANUAL

AIR FOR COMBUSTION AND VENTILATION

Continued

Ventilation Air From OutdoorsWARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3 or applicable local codes.

VENTILATION AIR

Ventilation Air From Inside Building

Ventilation

 

Grills

Or

into Adjoining

Remove

Room,

Door into

Option 1

Adjoining

 

Room,

 

Option 3

12"

Ventilation Grills

Into Adjoining Room,

Option 2

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see op- tion 3, Figure 2). Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Manual background WARNING: Rework work- sheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

12"

Figure 2 - Ventilation Air from Inside Building

Ventilated

Outlet Attic

Air

Outlet

 

Air

To Attic

 

To

Crawl

Space

Inlet

Air

Inlet Air

 

Ventilated

 

 

Crawl Space

 

 

Figure 3 - Ventilation Air from Outdoors

Continued

103548

5

Image 5
Contents INFRARED VENT-FREEPROPANE/LP GAS HEATER OWNER’S OPERATION AND INSTALLATION MANUALCGP10R CGP10RLPRODUCT FEATURES SAFETY INFORMATIONGAS RESIDENTIAL HEATERS LOCAL CODESAIR FOR COMBUSTION AND VENTILATION PRODUCT IDENTIFICATIONUnusually Tight Construction PROVIDING ADEQUATE VENTILATIONGAS RESIDENTIAL HEATERS ContinuedAIR FOR COMBUSTION AND VENTILATION DETERMINING AIR FLOW FOR HEATER LOCATIONContinued AIR FOR COMBUSTION AND VENTILATIONVentilation Air From Inside Building Ventilation Air From OutdoorsINSTALLATION ITEMS INSTALLING TO WALLGAS RESIDENTIAL HEATERS CHECK GAS TYPEInstalling Two Mounting Screws INSTALLING TO WALLInstalling Bottom Mounting Screw ContinuedINSTALLING TO WALL CONNECTING TO GAS SUPPLYGAS RESIDENTIAL HEATERS ContinuedPRESSURE TESTING GAS SUPPLY PIPING SYSTEM CHECKING GAS CONNECTIONSPRESSURE TESTING HEATER GAS CONNECTIONS Test Pressures In Excess Of 1/2 PSIGOPERATING HEATER FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS TO SELECT HEATING LEVELINSPECTING BURNER MANUAL LIGHTING PROCEDURETO TURN OFF GAS TO APPLIANCE OPERATING HEATERACCESSORY SPECIFICATIONSTROUBLESHOOTING OBSERVED PROBLEMOBSERVEDPROBLEM TROUBLESHOOTINGContinued POSSIBLE CAUSESERVICE HINTS TECHNICAL SERVICETROUBLESHOOTING OBSERVEDPROBLEMREPLACEMENT PARTS CLEANING AND MAINTENANCESERVICE PUBLICATIONS PARTS CENTRALSGAS RESIDENTIAL HEATERS ILLUSTRATED PARTS BREAKDOWN CGP10R CGP10RL8 4 7 22 25 5 6 GRH VP11APART PARTS LIST CGP10R CGP10RLNUMBER DESCRIPTIONGAS RESIDENTIAL HEATERS Page COMFORT GLOW VENT-FREERESIDENTIAL GAS HEATERS WARRANTY INFORMATIONLIMITED WARRANTY