CHECKING GAS CONNECTIONS

OWNER’S MANUAL

CHECKING GAS CONNECTIONS

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM WARNING: Test all gas pip- ing and connections for leaks after installation or servicing. Correct all leaks at once

Test Pressures In Excess Of 1/2WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

Test Pressures Equal To or Less Than 1/2 PSIG CAUTION: Make sure exter- nal regulator has been installed between propane/LP supply and heater. See guidelines under Con- necting to Gas Supply, page 8.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2

PSIG

1.Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where manual shutoff valve was connected.

3.Pressurize supply piping system by either using compressed air or opening propane/LP supply tank valve.

4.Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

Test Pressures Equal To or Less Than 1/2 PSIG

1.Close manual shutoff valve (see Figure 14).

2.Pressurize supply piping system by either using compressed air or opening propane/LP supply tank valve.

3.Check all joints from propane/LP supply tank to manual shutoff valve (see Figure 15). Apply mixture of liquid

soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

PRESSURE TESTING

HEATER GAS

CONNECTIONS

1.Open manual shutoff valve (see Figure 14).

2.Open propane/LP supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from manual shutoff

Manual Shutoff Valve

Figure 14 - Manual Shutoff Valve

Propane/LP

Supply Tank

Figure 15 - Checking Gas Joints

valve to control valve (see Figure 15). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 10 and11). Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas To Appliance, page 11).

8.Replace front panel.

Open

Closed

Control

PRESSURE TESTING Valve

Location

Manual

Shutoff

Valve

103548

9

Image 9
Contents INFRARED VENT-FREEPROPANE/LP GAS HEATER OWNER’S OPERATION AND INSTALLATION MANUALCGP10R CGP10RLPRODUCT FEATURES SAFETY INFORMATIONGAS RESIDENTIAL HEATERS LOCAL CODESAIR FOR COMBUSTION AND VENTILATION PRODUCT IDENTIFICATIONUnusually Tight Construction PROVIDING ADEQUATE VENTILATIONGAS RESIDENTIAL HEATERS ContinuedAIR FOR COMBUSTION AND VENTILATION DETERMINING AIR FLOW FOR HEATER LOCATIONContinued AIR FOR COMBUSTION AND VENTILATIONVentilation Air From Inside Building Ventilation Air From OutdoorsINSTALLATION ITEMS INSTALLING TO WALLGAS RESIDENTIAL HEATERS CHECK GAS TYPEInstalling Two Mounting Screws INSTALLING TO WALLInstalling Bottom Mounting Screw ContinuedINSTALLING TO WALL CONNECTING TO GAS SUPPLYGAS RESIDENTIAL HEATERS ContinuedPRESSURE TESTING GAS SUPPLY PIPING SYSTEM CHECKING GAS CONNECTIONSPRESSURE TESTING HEATER GAS CONNECTIONS Test Pressures In Excess Of 1/2 PSIGOPERATING HEATER FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS TO SELECT HEATING LEVELINSPECTING BURNER MANUAL LIGHTING PROCEDURETO TURN OFF GAS TO APPLIANCE OPERATING HEATERACCESSORY SPECIFICATIONSTROUBLESHOOTING OBSERVED PROBLEMOBSERVEDPROBLEM TROUBLESHOOTINGContinued POSSIBLE CAUSESERVICE HINTS TECHNICAL SERVICETROUBLESHOOTING OBSERVEDPROBLEMREPLACEMENT PARTS CLEANING AND MAINTENANCESERVICE PUBLICATIONS PARTS CENTRALSGAS RESIDENTIAL HEATERS ILLUSTRATED PARTS BREAKDOWN CGP10R CGP10RL8 4 7 22 25 5 6 GRH VP11APART PARTS LIST CGP10R CGP10RLNUMBER DESCRIPTIONGAS RESIDENTIAL HEATERS Page WARRANTY INFORMATION LIMITED WARRANTYCOMFORT GLOW VENT-FREERESIDENTIAL GAS HEATERS