Desa CGP10R Specifications, Accessory, Troubleshooting, Gas Residential Heaters, Observed Problem

Page 12
SPECIFICATIONS

GAS RESIDENTIAL HEATERS

SPECIFICATIONS

Btu (Variable)

5,500/10,000

Type Gas

Propane/LP Only

Ignition

Piezo

Pressure Regulator Setting

8" W.C.

Inlet Gas Pressure (inches of water)

 

Maximum

14"

Minimum

11"

Dimensions, Inches (H x W x D)

 

Heater

20 1/2 x 13 1/2 x 5

Carton

25 x 16 11/16 x 7 1/2

Weight (pounds)

 

Heater

14

Shipping

18

ACCESSORY

Purchase this heater accessory from your local dealer. If they cannot supply this accessory, either contact your nearest Parts Central (see above) or call DESA International’s Parts Department at 1-800-972- 7879 for referral information. You can also write to the address listed on the back page of this manual.

MANUAL SHUTOFF

VALVE - GA5010

Manual shutoff valve with 1/8" NPT tap.

TROUBLESHOOTING

Note: All Trouble Shooting items are listed in order of operation.

ACCESSORY WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

TROUBLESHOOTING CAUTION: Never use a wire, needle, or similar object to clean ODS/ pilot. This can damage ODS/pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed and control knob is pressed in and turned to the PILOT position, there is no spark at ODS/pilot

1.Ignitor electrode positioned wrong

2.Ignitor electrode broken

3.Ignitor electrode not connected to ignitor cable

4.Ignitor cable pinched or wet

5.Piezo ignitor nut is loose

6.Broken ignitor cable

7.Bad piezo ignitor

1.Replace ignitor

2.Replace ignitor

3.Reconnect ignitor cable

4.Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry

5.Tighten nut holding piezo ignitor to heater cabinet. Nut is located inside heater cabinet at top

6.Replace ignitor cable

7.Replace piezo ignitor

When ignitor button is pressed and control

1.

Gas supply turned off or manual shutoff

1.

Turn on gas supply or open manual

knob is pressed in and turned to the PILOT

 

valve closed

 

shutoff valve

position, there is spark at ODS/pilot but no

2.

Control knob not in PILOT position

2.

Turn control knob to PILOT position

ignition

3.

Control knob not pressed in while in

3.

Press in control knob while in PILOT

 

 

PILOT position

 

position

 

4.

Air in gas lines when installed

4.

Continue holding down control knob.

 

 

 

 

Repeat igniting operation until air is

 

 

 

 

removed

 

5.

Depleted gas supply

5.

Contact local propane/LP gas company

 

6.

ODS/pilot is clogged

6.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 15) or replace ODS/

 

 

 

 

pilot assembly

 

7.

Gas regulator setting is not correct

7.

Replace gas regulator

12

103548

Image 12
Contents OWNER’S OPERATION AND INSTALLATION MANUAL INFRARED VENT-FREEPROPANE/LP GAS HEATERCGP10R CGP10RLSAFETY INFORMATION PRODUCT FEATURESGAS RESIDENTIAL HEATERS LOCAL CODESPRODUCT IDENTIFICATION AIR FOR COMBUSTION AND VENTILATIONUnusually Tight Construction PROVIDING ADEQUATE VENTILATIONContinued GAS RESIDENTIAL HEATERSAIR FOR COMBUSTION AND VENTILATION DETERMINING AIR FLOW FOR HEATER LOCATIONAIR FOR COMBUSTION AND VENTILATION ContinuedVentilation Air From Inside Building Ventilation Air From OutdoorsINSTALLING TO WALL INSTALLATION ITEMSGAS RESIDENTIAL HEATERS CHECK GAS TYPEINSTALLING TO WALL Installing Two Mounting ScrewsInstalling Bottom Mounting Screw ContinuedCONNECTING TO GAS SUPPLY INSTALLING TO WALLGAS RESIDENTIAL HEATERS ContinuedCHECKING GAS CONNECTIONS PRESSURE TESTING GAS SUPPLY PIPING SYSTEMPRESSURE TESTING HEATER GAS CONNECTIONS Test Pressures In Excess Of 1/2 PSIGFOR YOUR SAFETY READ BEFORE LIGHTING OPERATING HEATERLIGHTING INSTRUCTIONS TO SELECT HEATING LEVELMANUAL LIGHTING PROCEDURE INSPECTING BURNERTO TURN OFF GAS TO APPLIANCE OPERATING HEATERSPECIFICATIONS ACCESSORYTROUBLESHOOTING OBSERVED PROBLEMTROUBLESHOOTING OBSERVEDPROBLEMContinued POSSIBLE CAUSETECHNICAL SERVICE SERVICE HINTSTROUBLESHOOTING OBSERVEDPROBLEMCLEANING AND MAINTENANCE REPLACEMENT PARTSSERVICE PUBLICATIONS PARTS CENTRALSILLUSTRATED PARTS BREAKDOWN CGP10R CGP10RL GAS RESIDENTIAL HEATERS8 4 7 22 25 5 6 GRH VP11APARTS LIST CGP10R CGP10RL PARTNUMBER DESCRIPTIONGAS RESIDENTIAL HEATERS Page WARRANTY INFORMATION LIMITED WARRANTYCOMFORT GLOW VENT-FREERESIDENTIAL GAS HEATERS