Desa CGP10RL installation manual Installing To Wall, Continued, Marking Screw Locations

Page 7
Marking Screw Locations

OWNER’S MANUAL

INSTALLING

TO WALL

Continued

INSTALLING HEATER TO WALL

Marking Screw Locations

1.Determine where you will locate heater.

Attaching to Wall Anchor Method WARNING: Maintain minimum clearances shown in Figure 5. If you can, provide greater clear- ances from floor and joining wall.

2.Mark two mounting screw locations on wall (see Figure 5).

Attaching to Wall Anchor Method

Follow instructions below to attach mount- ing screws to hollow walls (wall areas be- tween studs) or solid walls (concrete or masonry).

1.Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1 1/4" deep.

2.Fold wall anchor (see Figure 6).

3.Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

Placing Heater on Mounting Screws

1.Locate two keyhole slots on back panel of heater (see Figure 9).

2.Place large openings of slots over screwheads. Slide heater down until screws are in small portion of slots.

Keyhole

Slots

Figure 9 - Location Of Keyhole Slots On Back Panel Of Heater

Removing Front Panel of Heater

 

 

10 7/8"

 

 

 

 

7 3/4"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum To

 

 

 

 

 

 

 

 

 

 

Maintain 6"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clearance

 

 

 

 

 

 

 

 

 

 

From Wall

 

 

 

 

 

 

 

 

 

 

 

Mounting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WALL

 

Screw

 

 

 

 

 

 

 

 

 

 

 

Locations

 

20 1/4"

 

 

 

 

 

 

 

 

 

 

JOINING

 

 

 

 

 

Minimum To

 

 

 

 

 

 

Maintain 3"

 

 

 

 

 

 

 

 

 

 

 

Clearance

From Floor

FLOOR

Figure 5 - Mounting Screw Locations

Installing Two Mounting Screws

Note: Wall anchors and mounting screws are in hardware package. The hardware pack- age is provided with heater.

Attaching to Wall Stud Mmethod

For attaching mounting screw to wall stud

1.Drill hole at marked location using 9/ 64" drill bit.

2.Insert mounting screw into wall stud.

3.Tighten screw until 1/16" space (thickness of penny) is between

screwhead and wall.

Figure 6 - Folding Anchor

4.For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings (see Figure 7). IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings.

Thin Walls

(1/4" to 1/2" thick)

Figure 7 - Popping Open Anchor Wings For Thin Walls

5.Tighten two screws until 1/16" space (thickness of penny) is between screwheads and wall (see Figure 8).

Thin or Thick Wall (thick wall shown)

1/16" Space

Solid

Wall

Figure 8 - Tightening Anchors

1.Remove two screws near bottom corners of front panel.

2.Lift straight up on grill guard until it stops. Grill guard will slide up about 1/4".

3.Pull bottom of front panel forward, then down.

Figure 10 - Removing Front Panel Of Heater

Installing Bottom Mounting Screw

1.Locate bottom mounting hole. This hole is near bottom on back panel of heater (see Figure 11, page 8).

2.Mark screw location on wall.

3.Remove heater from wall.

Continued

103548

7

Image 7
Contents CGP10RL OWNER’S OPERATION AND INSTALLATION MANUALINFRARED VENT-FREEPROPANE/LP GAS HEATER CGP10RLOCAL CODES SAFETY INFORMATIONPRODUCT FEATURES GAS RESIDENTIAL HEATERSPROVIDING ADEQUATE VENTILATION PRODUCT IDENTIFICATIONAIR FOR COMBUSTION AND VENTILATION Unusually Tight ConstructionDETERMINING AIR FLOW FOR HEATER LOCATION ContinuedGAS RESIDENTIAL HEATERS AIR FOR COMBUSTION AND VENTILATIONVentilation Air From Outdoors AIR FOR COMBUSTION AND VENTILATIONContinued Ventilation Air From Inside BuildingCHECK GAS TYPE INSTALLING TO WALLINSTALLATION ITEMS GAS RESIDENTIAL HEATERSContinued INSTALLING TO WALLInstalling Two Mounting Screws Installing Bottom Mounting ScrewContinued CONNECTING TO GAS SUPPLYINSTALLING TO WALL GAS RESIDENTIAL HEATERSTest Pressures In Excess Of 1/2 PSIG CHECKING GAS CONNECTIONSPRESSURE TESTING GAS SUPPLY PIPING SYSTEM PRESSURE TESTING HEATER GAS CONNECTIONSTO SELECT HEATING LEVEL FOR YOUR SAFETY READ BEFORE LIGHTINGOPERATING HEATER LIGHTING INSTRUCTIONSOPERATING HEATER MANUAL LIGHTING PROCEDUREINSPECTING BURNER TO TURN OFF GAS TO APPLIANCEOBSERVED PROBLEM SPECIFICATIONSACCESSORY TROUBLESHOOTINGPOSSIBLE CAUSE TROUBLESHOOTINGOBSERVEDPROBLEM ContinuedOBSERVEDPROBLEM TECHNICAL SERVICESERVICE HINTS TROUBLESHOOTINGPARTS CENTRALS CLEANING AND MAINTENANCEREPLACEMENT PARTS SERVICE PUBLICATIONSGRH VP11A ILLUSTRATED PARTS BREAKDOWN CGP10R CGP10RLGAS RESIDENTIAL HEATERS 8 4 7 22 25 5 6DESCRIPTION PARTS LIST CGP10R CGP10RLPART NUMBERGAS RESIDENTIAL HEATERS Page LIMITED WARRANTY WARRANTY INFORMATIONCOMFORT GLOW VENT-FREERESIDENTIAL GAS HEATERS