Desa CGP6L, CGP10L Inspecting Burner, Lighting Instructions, Manual Lighting Procedure

Page 10
C-clockwise

10,000 AND 6,000 BTU/HR PROPANE/LP GAS HEATER

OPERATING

HEATER

Continued

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information page 9, column 3.

2.Make sure manual shutoff valve is fully open.

3. Turn control knob clockwise Clockwise to the OFF position.

Ignitor Button

 

Control Knob

 

PILOT

OFF

 

 

HIGH

IGNITOR

LOW

Figure 16 - Control Knob In The OFF Position

4. Wait five (5) minutes to clear out any

gas. Then smell for gas, including

near the floor. If you smell gas,

STOP! Follow “B” in the safety in-

formation at the top of page 16. If you

don’t smell gas, go to the next step.

person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

 

Ignitor Electrode

Thermocouple

Pilot Burner

 

Figure 17 - Pilot

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

8.Turn control knob counterclockwise

C-clockwiseto the HIGH position. The main burner should light. Set control knob to any heat level between HIGH and LOW. To turn control knob from HIGH to a lower setting, press in the control knob and turn counterclock-

wise C-clockwise .

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 10, page 7).

2.Follow steps 1 through 5 under Light- ing Instructions.

3.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

4.Keep control knob pressed in for 30 seconds after pilot is lit. After 30 sec- onds, release control knob.

5.Replace front panel.

INSPECTING

BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 18 shows a correct pilot flame pat- tern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

5. Press in control knob and turn coun-

terclockwise to the PILOT position. Keep control knob pressed in for five (5) seconds (see Figure 16).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 12 through 14. Also contact a qualified service

Note: Both HIGH and LOW are locked positions. You must press in control knob before turning it from these positions.

CAUTION: Do not try to ad- just heating levels by using the manual shutoff valve.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

 

1. Turn control knob clockwise

Clockwise

to the PILOT position.

 

2.Press in control knob and turn clock- wise Clockwise to the OFF position.

Shutting Off Burner Only (pilot stays lit)

1. Turn control knob clockwise Clockwise to the PILOT position.

Pilot Burner

Thermocouple

Figure 18 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

FigureBAD19PILOT/LP- Incorrect Pilot FlameGRH/OVPattern008

If pilot flame pattern is incorrect, as shown in Figure 19

turn heater off (see To Turn Off Gas to Appliance)

see Troubleshooting, pages 12 through 14

10

103547

Image 10
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASLocal Codes Safety InformationProduct Features UnpackingProviding Adequate Ventilation Product IdentificationFresh AIR for Combustion and Ventilation Unusually Tight ConstructionVentilation AIR Determining FRESH-AIR Flow for Heater LocationVentilation Air From Inside Building Fresh AIR for Combustion Ventilation Ventilation Air From OutdoorsInstalling Heater to Wall Installing to WallInstallation Items Check GAS TypePlacing Heater On Mounting Screws Installing Bottom Mounting ScrewAttaching to wall anchor method Removing Front Panel Of HeaterConnecting to GAS Supply External Regulator With Vent Pointing DownChecking GAS Connections Operating HeaterLighting Instructions Manual Lighting ProcedureInspecting Burner Pilot Flame PatternODS/PILOT and Burner Orifice Cleaning and MaintenanceBurner Flame Pattern CabinetTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Service Hints Technical ServiceAccessory Service Publications SpecificationsReplacement Parts Parts CentralsIllustrated Parts List CGP10L CGP6LParts Available not Shown 10,000 and 6,000 BTU/HR PROPANE/LP GAS Heater 103547 Warranty Information

CGP10L, CGP6L specifications

Desa's CGP10L and CGP6L are two innovative gas-powered heating solutions designed for both residential and commercial applications. These models highlight an impressive combination of efficiency, convenience, and modern technology tailored to meet diverse heating needs.

The CGP10L is a robust heater with a capacity of 10,000 BTUs, making it an ideal choice for larger spaces or areas requiring extensive heating. In contrast, the CGP6L offers a slightly lower output of 6,000 BTUs, perfect for smaller rooms or as supplemental heating in larger environments. Both models are designed to deliver reliable warmth while maintaining energy efficiency, which is crucial for cost-effective household management.

One of the standout features of the CGP10L and CGP6L is the use of advanced infrared technology. This technology allows for quick and efficient heating by warming objects and people directly rather than merely heating the air. As a result, users can experience immediate comfort without the typical waiting times associated with traditional heating systems.

In terms of design, both models feature a compact and lightweight construction, enabling easy portability. This is particularly beneficial for users who may want to move their heater from room to room or even take it outdoors. The built-in safety features, such as automatic shut-off functions and tip-over protection, enhance the safety profile of these units, making them suitable for various living conditions.

Moreover, Desa has incorporated user-friendly controls in both models, allowing users to adjust the heat output according to their comfort preferences. The straightforward operation ensures that even those who are not technically inclined can benefit from these powerful heating systems.

The fuel efficiency of the CGP10L and CGP6L is another attractive characteristic, as both models are designed to minimize gas consumption while maximizing heat output. This not only contributes to lower utility bills but also aligns with eco-friendly practices.

In conclusion, Desa's CGP10L and CGP6L heaters stand out in the market due to their modern technology, efficiency, portability, and safety features. Whether for residential or commercial use, these models provide a reliable heating solution tailored to meet the varying demands of consumers.