Desa CGN10R installation manual Pressure Testing Heater GAS Connections, Manual Shutoff Valve

Page 15

CHECKING GAS CONNECTIONS

Continued

4.Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

Test Pressures Equal To or Less Than 1/2 PSIG

1.Close manual shutoff valve (see Figure 13).

2.Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.

3.Check all joints from gas meter to manual shutoff valve (see Figure 14). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

PRESSURE TESTING HEATER GAS CONNECTIONS

1.Open manual shutoff valve (see Figure 13).

2.Open main gas valve located on or near gas meter.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from manual shutoff valve to control valve (see Figure 14). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 16 through 19). Check the rest of the internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 19).

8.Replace front panel.

Open

Manual

Shutoff

Valve

Closed

Figure 13 - Manual Shutoff Valve

Control Valve Location

Gas Meter

Manual

Shutoff

Valve

Figure 14 - Checking Gas Joints

15

101867

Image 15
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Information Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device Product IdentificationUnconfined Space Fresh AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air from Outdoors Ventilation Air From OutdoorsInstallation Items Check GAS TypeLocating Heater Marking Screw Locations Installing Heater to WallFolding Anchor Installing Two Mounting ScrewsPlacing Heater On Mounting Screws Connecting to GAS Supply Checking GAS Connections ConnectingPressure Testing GAS Supply Piping System To GAS SupplyManual Shutoff Valve Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingPilot To Select Heating Level Pilot Flame Pattern Manual Lighting ProcedureOperating Heater Inspecting Burner To Turn OFF GAS to ApplianceCorrect Burner Flame Pattern Burner Flame PatternAir Passageways Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner Orifice CabinetTROUBLE- Shooting See CleaningMaintenance , TROUBLE- Shooting Technical Service Ing statement atTop Service Hints Replacement Parts Parts Under WarrantyParts Not Under Warranty Service Publications Accessory Parts CentralsValve GA5010 Illustrated Parts Breakdown Parts List CGN10RKeep this Warranty Warranty Information