24
TROUBLE- SHOOTING
Continued
TECHNICAL SERVICE
WARNING
If you smell gas
•Shut off gas supply.
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.
OBSERVED | POSSIBLE |
|
|
| ||
PROBLEM | CAUSE | REMEDY | ||||
|
|
|
|
|
|
|
Heater produces | 1. | Heater burning vapors | 1. | Ventilate room. Stop | ||
unwanted odors |
| from paint, hair spray, |
| using | ||
|
|
| glues, etc., (see IMPOR- |
| products while heater is | |
|
|
| TANT statement above). |
| running | |
|
| 2. | Gas leak. See Warn- | 2. | Locate and correct all | |
|
|
| ing statement at |
| leaks (see Checking Gas | |
|
|
| top of page |
| Connections, page 14) | |
|
|
|
|
|
|
|
Heater shuts off in | 1. | Not enough fresh air is | 1. | Refer to Fresh Air for | ||
use (ODS operates) |
| available |
| Combustion and Venti- | ||
|
|
|
|
| lation requirements | |
|
| 2. | Low line pressure |
| (page 5) | |
|
| 2. | Contact local natural | |||
|
|
|
|
| gas company | |
|
| 3. | ODS/pilot is partially | 3. | Clean ODS/pilot (see | |
|
|
| clogged |
| Cleaning and Mainte- | |
|
|
|
|
| nance, page 21) | |
|
|
|
|
|
| |
Gas odor even when | 1. Gas leak. See Warn- | 1. | Locate and correct all | |||
control knob is in |
| ing statement at |
| leaks (see Checking | ||
OFF position |
| top of page |
| Gas Connections, | ||
|
|
|
|
| page 14) | |
|
| 2. | Control valve defective | 2. | Replace control valve | |
|
|
|
|
|
| |
Gas odor during | 1. | Foreign matter be- | 1. | Take apart gas tubing | ||
combustion |
| tween control valve |
| and remove foreign | ||
|
|
| and burner |
| matter | |
|
| 2. | Gas leak. See Warn- | 2. | Locate and correct all | |
|
|
| ing statement at |
| leaks (see Checking Gas | |
|
|
| top of page |
| Connections, page 14) | |
|
|
|
|
| ||
Moisture/condensation | 1. Not enough combus- | 1. | Refer to Fresh Air for | |||
noticed on windows |
| tion/ventilation air. |
| Combustion and Venti- | ||
|
|
|
|
| lation requirements | |
|
|
|
|
| (page 5) |
You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at
101867