Desa CGG2618P Installation Items Needed, Attaching Flexible Gas Hose to Heater Gas Regulator

Page 11

OWNER’S MANUAL

INSTALLATION

Installation Items Needed

hardware package (provided with heater)

approved flexible gas hose (not provided) (if allowed by local codes)

sealant (resistant to propane/LP gas, not provided)

electric drill with 3/16" masonry drill bit

1.Apply pipe joint sealant lightly to male threads of gas connector and install into regulator. Connect approved flexible gas hose to gas regulator of heater (see Figure 11).

IMPORTANT: Hold gas regulator with wrench when connecting fittings.

2.Position heater base assembly in fire- place.

3.Mark screw locations through holes in front of base. If installing in a brick- bottom fireplace, mark screw locations in mortar joint of bricks.

4.Remove heater base from fireplace.

5.Drill holes at marked locations using 3/16" drill bit. Drill at a 45° angle.

6.Attach base to fireplace floor using masonry screws in hardware package (see Figure 12).

7.Connect to gas supply. See Connecting To Gas Supply, page 12.

Heater Gas

Regulator

Flexible Gas Hose (if allowed by local codes)

Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator

Masonry

Screw

Figure 12 - Attaching Heater to Fireplace Floor

Continued

103425

11

Image 11
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualUnvented VENT-FREE GAS LOG Heater Safety InformationUnpacking Product FeaturesProduct Identification Local CodesConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside BuildingMinimum Fireplace Clearance to Combustible Materials InstallationInstallation Clearances Check GAS TypeMinimum Noncombustible Material Clearances If Using MantelDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationAttaching Flexible Gas Hose to Heater Gas Regulator Installation Items NeededExternal Regulator With Vent Pointing Down Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Installing Rear Log Installing LogsLighting Instructions For Your Safety Read Before LightingOperating Heater Thermostat Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Pilot Flame Pattern Inspecting BurnersVariable Control Operation Logs Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Front Burner Flame PatternObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at For Masonry and FACTORY-BUILT Metal Fireplace Optional Positioning of Thermostat Sensing BulbReplacement Parts SpecificationsService Hints Technical ServiceVariable Manually Controlled Models Illustrated Parts BreakdownVariable MANUALLY- Controlled Models Parts ListThermostat Controlled Models KEY Part Number Description QTY CGG3324PTParts Centrals Accessories103425 Keep this Warranty Warranty Information

CGG2618P, CGG3324P(T), CGG3630P specifications

Desa CGG2618P, CGG3630P, and CGG3324P(T) are exceptional models from Desa that showcase innovative technology and thoughtful engineering, tailored for a variety of heating needs. Each of these models brings unique features and characteristics, catering to both residential and commercial applications while ensuring efficiency and performance.

The CGG2618P model is known for its compact design and powerful heating capabilities. It features a 26,000 BTU heating capacity, making it an ideal choice for spaces that require rapid and effective warmth. The unit employs advanced ceramic combustion technology that enhances fuel efficiency, allowing users to enjoy the comfort of heat without excessive energy consumption. Its user-friendly interface includes an adjustable thermostat, enabling precise temperature control tailored to individual preferences. Furthermore, the CGG2618P is equipped with safety features such as an automatic shut-off system, ensuring peace of mind during operation.

Moving on to the CGG3630P, this model boasts a larger heating capacity of 36,000 BTU, making it suitable for larger areas. This unit utilizes a dual burner system, which ensures even heat distribution throughout the space. The CGG3630P is designed with advanced insulation materials that contribute to its energy efficiency, minimizing heat loss and enhancing performance. Additionally, it offers multiple heat settings, allowing users to easily adjust the temperature based on their specific needs, whether it’s for quick heating or maintaining a steady warmth.

The CGG3324P(T) model distinguishes itself with its time and temperature control capabilities, making it a versatile option for users who want to schedule heating in advance. This model features a programmable thermostat, which can be programmed for different heating times throughout the day, promoting convenience and energy savings. With a 33,000 BTU capacity, the CGG3324P(T) is capable of heating medium to large rooms efficiently. Its sleek design and modern aesthetics allow it to blend seamlessly into various decor styles while its robust construction ensures durability.

All three models are equipped with high-performance safety features, offering reliable operation without compromising user safety. With their distinctive technologies and attributes, Desa CGG2618P, CGG3630P, and CGG3324P(T) provide effective and efficient heating solutions suitable for diverse settings, ensuring warmth and comfort all winter long.