Desa CGG3630P, CGG3324P(T), CGG2618P installation manual Gas leak. See Warning statement at

Page 21

OWNER’S MANUAL

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces a clicking/ticking noise just after burners are lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most heaters. If noise is excessive, contact qualified ser- vice person

Heater produces unwanted odors

1.

Heater burning vapors from paint, hair

1.

Open window to ventilate room. Stop us-

 

 

spray, glues, cleaners, chemicals, new

 

ing odor causing products while heater

 

 

carpet, etc. (See IMPORTANT state-

 

is running

 

 

ment above)

2.

Refill supply tank

 

2.

Low fuel supply

 

3.

Gas leak. See Warning statement at

3.

Locate and correct all leaks (see

 

 

top of page

 

Checking Gas Connections, page 13)

 

 

 

 

 

Heater shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Open window and/or door for ventilation

 

2.

Low line pressure

2.

Contact local propane/LP gas company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 18)

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement at

1.

Locate and correct all leaks (see

position

 

top of page

 

Checking Gas Connections, page 13)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between control valve

1.

Take apart gas tubing and remove for-

 

 

and burner

 

eign matter

 

2.

Gas leak. See Warning statement at

2.

Locate and correct all leaks (see

 

 

top of page

 

Checking Gas Connections, page 13)

 

 

 

 

 

Log set cycles to pilot, but room tempera-

1.

Thermostat sensing bulb needs to be re-

1.

Reposition thermostat sensing bulb (see

ture drops to a lower than ideal level before

 

positioned

 

Instructions for Optional Positioning of

log set comes back on

 

 

 

Thermostat Sensing Bulb, page 23)

www.desatech.com

103425

21

Image 21
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualUnvented VENT-FREE GAS LOG Heater Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsInstallation Clearances InstallationCheck GAS Type Minimum Fireplace Clearance to Combustible MaterialsMinimum Noncombustible Material Clearances If Using MantelMantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationAttaching Flexible Gas Hose to Heater Gas Regulator Installation Items NeededExternal Regulator With Vent Pointing Down Connecting to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections Installing Rear Log Installing LogsFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceThermostat Control Operation Inspecting Burners Variable Control OperationPilot Flame Pattern Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceFront Burner Flame Pattern LogsObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at For Masonry and FACTORY-BUILT Metal Fireplace Optional Positioning of Thermostat Sensing BulbService Hints SpecificationsTechnical Service Replacement PartsVariable Manually Controlled Models Illustrated Parts BreakdownVariable MANUALLY- Controlled Models Parts ListThermostat Controlled Models KEY Part Number Description QTY CGG3324PTParts Centrals Accessories103425 Keep this Warranty Warranty Information

CGG2618P, CGG3324P(T), CGG3630P specifications

Desa CGG2618P, CGG3630P, and CGG3324P(T) are exceptional models from Desa that showcase innovative technology and thoughtful engineering, tailored for a variety of heating needs. Each of these models brings unique features and characteristics, catering to both residential and commercial applications while ensuring efficiency and performance.

The CGG2618P model is known for its compact design and powerful heating capabilities. It features a 26,000 BTU heating capacity, making it an ideal choice for spaces that require rapid and effective warmth. The unit employs advanced ceramic combustion technology that enhances fuel efficiency, allowing users to enjoy the comfort of heat without excessive energy consumption. Its user-friendly interface includes an adjustable thermostat, enabling precise temperature control tailored to individual preferences. Furthermore, the CGG2618P is equipped with safety features such as an automatic shut-off system, ensuring peace of mind during operation.

Moving on to the CGG3630P, this model boasts a larger heating capacity of 36,000 BTU, making it suitable for larger areas. This unit utilizes a dual burner system, which ensures even heat distribution throughout the space. The CGG3630P is designed with advanced insulation materials that contribute to its energy efficiency, minimizing heat loss and enhancing performance. Additionally, it offers multiple heat settings, allowing users to easily adjust the temperature based on their specific needs, whether it’s for quick heating or maintaining a steady warmth.

The CGG3324P(T) model distinguishes itself with its time and temperature control capabilities, making it a versatile option for users who want to schedule heating in advance. This model features a programmable thermostat, which can be programmed for different heating times throughout the day, promoting convenience and energy savings. With a 33,000 BTU capacity, the CGG3324P(T) is capable of heating medium to large rooms efficiently. Its sleek design and modern aesthetics allow it to blend seamlessly into various decor styles while its robust construction ensures durability.

All three models are equipped with high-performance safety features, offering reliable operation without compromising user safety. With their distinctive technologies and attributes, Desa CGG2618P, CGG3630P, and CGG3324P(T) provide effective and efficient heating solutions suitable for diverse settings, ensuring warmth and comfort all winter long.