Desa CGG2618P, CGG3630P, CGG3324P(T) Minimum Noncombustible Material Clearances, If Using Mantel

Page 8

UNVENTED (VENT-FREE) GAS LOG HEATER

INSTALLATION

Continued

NOTICE: Manual control heaters may be used as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, noncombustible material above fireplace opening is not needed. Go to Installing Damper Clamp Accessory for Vented

If Using Mantel

You must have noncombustible material(s) above the fireplace opening. Noncombus- tible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible mate- rial must extend at least 8 inches up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). Even

if noncombustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See Figure 5 and Figures 6 and 7, page 9, for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 10.

Operation, page 10.

Minimum Noncombustible Material Clearances

If Not Using Mantel

Note: If using a mantel, proceed to If Using Mantel. If not using a mantel, follow the information on this page.

You must have noncombustible material(s) above the fireplace opening. Noncombus- tible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible mate- rial must extend at least 8" up (for all mod- els). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). See Figure 5 for minimum clearances.

IMPORTANT: If you cannot meet these mini- mum clearances, you must operate heater with chimney flue damper open. Go to In- stalling Damper Clamp Accessory for Vented Operation, page 10.

Noncombustible

Requirements for

Material Distance (A)

Safe Installation

 

 

12" or more

Noncombustible material OK.

Between 8" and 12"

24" or 30" Models: Install fireplace hood accessory

 

(GA6050 or GA6052, see Accessories, page 28).

 

18" Model: Noncombustible material OK. No hood

 

accessory needed.

Less than 8"

Noncombustible material must be extended to at

 

least 8". See Between 8" and 12", above. If you

 

cannot extend material, you must operate heater

 

with flue damper open.

Heat Resistant

Material

(A)

Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace

8

103425

Image 8
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information Unvented VENT-FREE GAS LOG HeaterProduct Features Product IdentificationLocal Codes UnpackingAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation Installation ClearancesCheck GAS Type Minimum Fireplace Clearance to Combustible MaterialsIf Using Mantel Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Attaching Flexible Gas Hose to Heater Gas RegulatorConnecting to GAS Supply External Regulator With Vent Pointing DownChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Installing Logs Installing Rear LogLighting Instructions For Your Safety Read Before LightingOperating Heater Thermostat Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Pilot Flame Pattern Inspecting BurnersVariable Control Operation Cleaning and Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleFront Burner Flame Pattern LogsTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Optional Positioning of Thermostat Sensing Bulb For Masonry and FACTORY-BUILT Metal FireplaceSpecifications Service HintsTechnical Service Replacement PartsIllustrated Parts Breakdown Variable Manually Controlled ModelsParts List Variable MANUALLY- Controlled ModelsThermostat Controlled Models CGG3324PT KEY Part Number Description QTYAccessories Parts Centrals103425 Warranty Information Keep this Warranty

CGG2618P, CGG3324P(T), CGG3630P specifications

Desa CGG2618P, CGG3630P, and CGG3324P(T) are exceptional models from Desa that showcase innovative technology and thoughtful engineering, tailored for a variety of heating needs. Each of these models brings unique features and characteristics, catering to both residential and commercial applications while ensuring efficiency and performance.

The CGG2618P model is known for its compact design and powerful heating capabilities. It features a 26,000 BTU heating capacity, making it an ideal choice for spaces that require rapid and effective warmth. The unit employs advanced ceramic combustion technology that enhances fuel efficiency, allowing users to enjoy the comfort of heat without excessive energy consumption. Its user-friendly interface includes an adjustable thermostat, enabling precise temperature control tailored to individual preferences. Furthermore, the CGG2618P is equipped with safety features such as an automatic shut-off system, ensuring peace of mind during operation.

Moving on to the CGG3630P, this model boasts a larger heating capacity of 36,000 BTU, making it suitable for larger areas. This unit utilizes a dual burner system, which ensures even heat distribution throughout the space. The CGG3630P is designed with advanced insulation materials that contribute to its energy efficiency, minimizing heat loss and enhancing performance. Additionally, it offers multiple heat settings, allowing users to easily adjust the temperature based on their specific needs, whether it’s for quick heating or maintaining a steady warmth.

The CGG3324P(T) model distinguishes itself with its time and temperature control capabilities, making it a versatile option for users who want to schedule heating in advance. This model features a programmable thermostat, which can be programmed for different heating times throughout the day, promoting convenience and energy savings. With a 33,000 BTU capacity, the CGG3324P(T) is capable of heating medium to large rooms efficiently. Its sleek design and modern aesthetics allow it to blend seamlessly into various decor styles while its robust construction ensures durability.

All three models are equipped with high-performance safety features, offering reliable operation without compromising user safety. With their distinctive technologies and attributes, Desa CGG2618P, CGG3630P, and CGG3324P(T) provide effective and efficient heating solutions suitable for diverse settings, ensuring warmth and comfort all winter long.