Desa CGG3630P, CGG3324P(T) Product Identification, Product Features, Local Codes, Unpacking

Page 3

OWNER’S MANUAL

PRODUCT

IDENTIFICATION

Bottom Mid

 

 

Log (#2)

Top Log (#4)

Rear Log (#1)

Front

Burner

Rear

Burner

Piezo

Ignitor

Front Log (#3)

Control Knob

Base Assembly

 

Figure 1 - Vent-Free Gas Log Heater

PRODUCT

FEATURES

OPERATION

This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by both realistic flames and glowing coals. This heater is designed for vent-free opera- tion. It has been tested and approved to ANS Z21.11.2 standard for unvented heaters. State and local codes in some areas prohibit the use of vent-free heaters. This heater may also be operated as a vented decorative (ANS Z21.60) product by opening the flue damper (non-thermostat operation only).

SAFETY PILOT

This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent- free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223, also known as NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note: Where listed vented decorative logs are required, thermostat operation is not permitted.

UNPACKING

CAUTION: Do not remove the metal data plates attached to the heater base assembly. The data plates contain important warranty information.

1.Remove logs and heater base assembly from carton. Note: Do not pick up heater base assembly by burners. This could damage heater. Always handle base assembly by grate.

2.Remove all protective packaging ap- plied to logs and heater for shipment.

3.Check all items for any shipping dam- age. If damaged, promptly inform dealer where you bought heater.

103425

3

Image 3
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualUnvented VENT-FREE GAS LOG Heater Safety InformationUnpacking Product FeaturesProduct Identification Local CodesConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside BuildingMinimum Fireplace Clearance to Combustible Materials InstallationInstallation Clearances Check GAS TypeMinimum Noncombustible Material Clearances If Using MantelDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationAttaching Flexible Gas Hose to Heater Gas Regulator Installation Items NeededExternal Regulator With Vent Pointing Down Connecting to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections Installing Rear Log Installing LogsFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceThermostat Control Operation Inspecting Burners Variable Control OperationPilot Flame Pattern Logs Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Front Burner Flame PatternObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at For Masonry and FACTORY-BUILT Metal Fireplace Optional Positioning of Thermostat Sensing BulbReplacement Parts SpecificationsService Hints Technical ServiceVariable Manually Controlled Models Illustrated Parts BreakdownVariable MANUALLY- Controlled Models Parts ListThermostat Controlled Models KEY Part Number Description QTY CGG3324PTParts Centrals Accessories103425 Keep this Warranty Warranty Information

CGG2618P, CGG3324P(T), CGG3630P specifications

Desa CGG2618P, CGG3630P, and CGG3324P(T) are exceptional models from Desa that showcase innovative technology and thoughtful engineering, tailored for a variety of heating needs. Each of these models brings unique features and characteristics, catering to both residential and commercial applications while ensuring efficiency and performance.

The CGG2618P model is known for its compact design and powerful heating capabilities. It features a 26,000 BTU heating capacity, making it an ideal choice for spaces that require rapid and effective warmth. The unit employs advanced ceramic combustion technology that enhances fuel efficiency, allowing users to enjoy the comfort of heat without excessive energy consumption. Its user-friendly interface includes an adjustable thermostat, enabling precise temperature control tailored to individual preferences. Furthermore, the CGG2618P is equipped with safety features such as an automatic shut-off system, ensuring peace of mind during operation.

Moving on to the CGG3630P, this model boasts a larger heating capacity of 36,000 BTU, making it suitable for larger areas. This unit utilizes a dual burner system, which ensures even heat distribution throughout the space. The CGG3630P is designed with advanced insulation materials that contribute to its energy efficiency, minimizing heat loss and enhancing performance. Additionally, it offers multiple heat settings, allowing users to easily adjust the temperature based on their specific needs, whether it’s for quick heating or maintaining a steady warmth.

The CGG3324P(T) model distinguishes itself with its time and temperature control capabilities, making it a versatile option for users who want to schedule heating in advance. This model features a programmable thermostat, which can be programmed for different heating times throughout the day, promoting convenience and energy savings. With a 33,000 BTU capacity, the CGG3324P(T) is capable of heating medium to large rooms efficiently. Its sleek design and modern aesthetics allow it to blend seamlessly into various decor styles while its robust construction ensures durability.

All three models are equipped with high-performance safety features, offering reliable operation without compromising user safety. With their distinctive technologies and attributes, Desa CGG2618P, CGG3630P, and CGG3324P(T) provide effective and efficient heating solutions suitable for diverse settings, ensuring warmth and comfort all winter long.