Desa CGG3324P(T), CGG3630P, CGG2618P To Turn OFF GAS To Appliance, Thermostat Control Operation

Page 16

UNVENTED (VENT-FREE) GAS LOG HEATER

OPERATING

HEATER

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise to the OFF position.

Shutting Off Burners Only (pilot stays lit)

Turn control knob clockwise to the PILOT position.

THERMOSTAT

CONTROL OPERATION

(Thermostat-Controlled

Models Only)

The thermostat control knob can be set to any comfort level between Hi and Lo. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

Note: Selecting the Hi setting with the control knob will cause the burners to remain fully on, without modulating down in most cases.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Light- ing Instructions, page 15.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, page 15.

Variable Manually-Controlled Models

FOR YOUR

SAFETY READ

BEFORE LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When light- ing the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un- der water.

LIGHTING

INSTRUCTIONS

WARNING:

If fireplace has glass doors, never operate this heater with glass doors closed. If you oper- ate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the High heat setting but will find the heat output excessive. You can open the chim- ney damper (if you have one) fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information column 2.

2.Make sure manual shutoff valve is fully open.

3.Press in and turn control knob clock-

wise

Clockwise

to the OFF

position.

 

 

 

 

HIPILOT

 

OFF

 

LO

Ignitor Button

Control Knob

Figure 23 - Control Knob and Ignitor Button Location

16

103425

Image 16
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information Unvented VENT-FREE GAS LOG HeaterProduct Features Product IdentificationLocal Codes UnpackingAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation Installation ClearancesCheck GAS Type Minimum Fireplace Clearance to Combustible MaterialsIf Using Mantel Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Attaching Flexible Gas Hose to Heater Gas RegulatorConnecting to GAS Supply External Regulator With Vent Pointing DownPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Installing Logs Installing Rear LogOperating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Variable Control Operation Inspecting BurnersPilot Flame Pattern Cleaning and Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleFront Burner Flame Pattern LogsTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Optional Positioning of Thermostat Sensing Bulb For Masonry and FACTORY-BUILT Metal FireplaceSpecifications Service HintsTechnical Service Replacement PartsIllustrated Parts Breakdown Variable Manually Controlled ModelsParts List Variable MANUALLY- Controlled ModelsThermostat Controlled Models CGG3324PT KEY Part Number Description QTYAccessories Parts Centrals103425 Warranty Information Keep this Warranty

CGG2618P, CGG3324P(T), CGG3630P specifications

Desa CGG2618P, CGG3630P, and CGG3324P(T) are exceptional models from Desa that showcase innovative technology and thoughtful engineering, tailored for a variety of heating needs. Each of these models brings unique features and characteristics, catering to both residential and commercial applications while ensuring efficiency and performance.

The CGG2618P model is known for its compact design and powerful heating capabilities. It features a 26,000 BTU heating capacity, making it an ideal choice for spaces that require rapid and effective warmth. The unit employs advanced ceramic combustion technology that enhances fuel efficiency, allowing users to enjoy the comfort of heat without excessive energy consumption. Its user-friendly interface includes an adjustable thermostat, enabling precise temperature control tailored to individual preferences. Furthermore, the CGG2618P is equipped with safety features such as an automatic shut-off system, ensuring peace of mind during operation.

Moving on to the CGG3630P, this model boasts a larger heating capacity of 36,000 BTU, making it suitable for larger areas. This unit utilizes a dual burner system, which ensures even heat distribution throughout the space. The CGG3630P is designed with advanced insulation materials that contribute to its energy efficiency, minimizing heat loss and enhancing performance. Additionally, it offers multiple heat settings, allowing users to easily adjust the temperature based on their specific needs, whether it’s for quick heating or maintaining a steady warmth.

The CGG3324P(T) model distinguishes itself with its time and temperature control capabilities, making it a versatile option for users who want to schedule heating in advance. This model features a programmable thermostat, which can be programmed for different heating times throughout the day, promoting convenience and energy savings. With a 33,000 BTU capacity, the CGG3324P(T) is capable of heating medium to large rooms efficiently. Its sleek design and modern aesthetics allow it to blend seamlessly into various decor styles while its robust construction ensures durability.

All three models are equipped with high-performance safety features, offering reliable operation without compromising user safety. With their distinctive technologies and attributes, Desa CGG2618P, CGG3630P, and CGG3324P(T) provide effective and efficient heating solutions suitable for diverse settings, ensuring warmth and comfort all winter long.