Desa CCL3930NT(A) Connecting to GAS Supply, Attaching Flexible Gas Hose to Heater Gas Regulator

Page 11

OWNER’S MANUAL

INSTALLATION

Continued

6.Drill holes at marked locations using 3/16" drill bit.

7.Attach base assembly to fireplace floor using two masonry screws (in hardware package) (see Figure 12).

8.Connect to gas supply. See Connect- ing To Gas Supply.

Fitting

Heater Gas

Regulator

Flexible Gas Hose (if allowed by local codes)

Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator

Masonry

Screw

Mounting

Bracket

Figure 12 - Attaching Base Assembly to Fireplace Floor

CONNECTING TO GAS SUPPLY

WARNING: A qualified ser- vice person must connect heater to gas supply. Follow all local codes.

Installation Items Needed

Before installing heater, make sure you have the items listed below.

piping (check local codes)

sealant (resistant to propane/LP gas)

manual shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur- chase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 25.

WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as well-head gas.

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13).

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

Install sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.

A.G.A. Design-Certified Manual Shutoff Valve With 1/8" NPT Tap*

From Gas

Approved Flexible

Gas Hose (if

Meter (5"

allowed by local

W.C.** to

codes)

10.5" W.C.

 

Pressure)

 

 

3" Minimum

Tee Joint Cap Pipe Nipple Gas

 

Regulator

Sediment Trap

Figure 13 - Gas Connection

*Purchase the optional A.G.A. design-cer- tified manual shutoff valve from your dealer. See Accessories, page 25.

**Minimum inlet pressure for purpose of input adjustment.

Continued

104385

11

Image 11
Contents Patent Pending What to do if YOU Smell GASWinchester Oak Model Shown Unvented Natural GAS LOG Heater Safety InformationUnpacking Product FeaturesProduct Identification Local CodesConfined Space and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside BuildingMinimum Wall and Ceiling Clearances see Figure InstallationCheck GAS Type Minimum Noncombustible Material Clearances If Using MantelIf Not Using Mantel Determining Minimum Mantel Clearance Mantel ClearancesFloor Clearances Chimney Minimum Permanent Height ft Flue Opening sq. ins Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededAttaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS SupplyTest Pressures In Excess Of 1/2 Psig Pressure Testing gas Supply Piping systemPressure Testing Heater Gas Connections Checking GAS ConnectionsInstalling Back Log Installing Logs on Models CGS2718N and CGS3124NDamage or personal injury Installing Logs on Models CLD3018N and CLD3924NTFront Log #1 Grate Fingers Grate Base Installing Logs on Model CCL3930NTALighting Instructions For Your Safety Read Before LightingOperating Heater Shutting Off Heater Manual Lighting ProcedureVariable Control Operation To Turn OFF GAS To ApplianceBurner Primary AIR Holes Inspecting BurnersThermostat Control Operation Pilot Flame PatternODS/PILOT and Burner Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Main BurnerObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at TopFor Masonry and Factory- built Metal Fireplace Optional POSI- Tioning of THER- Mostat Sensing BulbReplacement Parts SpecificationsTechnical Service Service HintsFireplace Hood AccessoriesParts Central Manual ShutoffIllustrated Parts Breakdown CGS2718N CGS3124N Parts ListUnvented Natural GAS LOG Heater CLD3018N CLD3924NT KEY CLD3924NT Part Number Description QTY CCL3930NTA CCL3930NT CCL3930NTA CCL3930NT CCL3930NTAWarranty Information