Desa VS18NRA, CFS18NRA, VS24NRA, VS30NRA Cleaning and Maintenance, Replacement Parts

Page 18

DESA INTERNATIONAL

UNVENTED NATURAL GAS LOG HEATER

CLEANING AND MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hairs with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

CAUTION: You must keep control areas, burners, and cir- culating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, and lint. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We rec- ommend that you clean the unit every 2,500 hours of operation or every three months.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recom- mend using compressed air no greater than 30 PSI. Your local computer store, hard- ware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the direc- tions on the can. If you don't follow direc- tions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 28).

3.Blow air through the ports/slots and holes in the burner.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 29). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Injector Holder

Ports/Slots

Burner

Tube

Primary Air Inlet

Holes

Figure 28 - Injector Holder On Outlet Burner Tube

Pilot Air Inlet

Hole

Pilot Assembly

Figure 29 - Pilot Inlet Air Hole

LOGS

If you remove logs for cleaning, refer to Installing Logs, page 13 , to properly re- place logs.

Replace log(s) if broken or chipped (dime-sized or larger).

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Techni- cal Service Department at 1-800-323-5190.

When calling DESA International, have ready

your name

your address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the defec- tive part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information.

When calling DESA International, have ready

model number of your heater

the replacement part number

18

104416

Image 18
Contents Desa International What to do if YOU Smell GASSafety Information Desa International Unvented Natural GAS LOG HeaterLocal Codes Product Identification FeaturesOptional Remote Control Accessories UnpackingUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Building Ventilation AIRVentilation Air From Inside Ventilation Air From OutdoorsCheck GAS Type InstallationInstallation Clearances Vent-Free Operation OnlyIf Using Mantel Minimum Noncombustible Material ClearancesMantel Clearances Floor ClearancesInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Area of Various Standard Round FluesConnecting to GAS Supply Attaching Flexible Gas Hose to Heater Gas RegulatorPressure Testing Heater Gas Connections Pressure Testing gas Supply Piping systemChecking GAS Connections Installing Logs For Your Safety Read Before Lighting Operating HeaterLighting Instructions Shutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off Burners Only pilot stays litGhrc Operation Optional Remote OperationThermostat Control Operation Ghrct OperationInspecting Burners Pilot Flame PatternFront Burner Flame Pattern Cleaning and Maintenance Replacement PartsTroubleshooting Observed Problem Possible Cause RemedySee Wiring Diagram, Gas leak. See Warning statement Illustrated Parts BREAKDOWN4 Variable Control CFS18NRA, VS18NRA VS24NRA, VS30NRAParts List VS24NRA VS30NRA Description QTYWiring Diagram SpecificationsTechnical Service Service HintsAccessories Warranty Information International

VS30NRA, VS18NRA, VS24NRA, CFS18NRA specifications

Desa, a well-known manufacturer in the heating and light industry, has developed several innovative products: the VS24NRA, VS30NRA, CFS18NRA, and VS18NRA. Each of these models showcases unique features, advanced technologies, and characteristics designed to cater to diverse consumer needs.

Starting with the VS24NRA, this unit is celebrated for its efficient heating capabilities. It boasts a powerful design, ideal for medium-sized spaces. Featuring an advanced combustion system, it ensures optimal fuel usage, translating to lower running costs and reduced environmental impact. The VS24NRA is equipped with an adjustable thermostat, allowing users to maintain desired temperatures easily. Its sleek and modern design allows it to fit seamlessly into various interior environments.

Next, the VS30NRA takes heating efficiency a step further. With a higher BTU output, it is suitable for larger spaces requiring more substantial heating solutions. This model incorporates cutting-edge heat distribution technology, ensuring even warmth throughout the room. Additionally, the VS30NRA is built with premium materials that enhance its durability, making it a long-term investment for homeowners. Its electronic ignition system contributes to convenience, allowing for quick and hassle-free startups.

The CFS18NRA stands out with its dual functionality by combining both heating and cooking capabilities. This model is ideal for those looking to maximize utility in smaller spaces. It features a contemporary design and compact build, making it an excellent addition to cabins, tiny homes, or other limited areas. The CFS18NRA utilizes infrared heating technology, which warms objects directly rather than relying solely on heating the air, creating a cozy atmosphere with minimal energy consumption.

Finally, the VS18NRA offers a balance between size and efficiency. It is tailored for modest environments, providing consistent warmth without overwhelming the space. The VS18NRA comes equipped with a user-friendly control panel, giving users precise control over settings. Its portability makes it a versatile choice for different rooms in a home or for outdoor gatherings.

In summary, Desa’s range, including the VS24NRA, VS30NRA, CFS18NRA, and VS18NRA, caters to a variety of heating needs. Their use of innovative technologies and emphasis on efficiency showcases Desa’s commitment to quality and customer satisfaction. Each model presents distinct features that make them suitable for a range of applications, ensuring homeowners can find the right solution for their heating needs.