Desa VS30NRA, CFS18NRA Installation Clearances, Check GAS Type, Vent-Free Operation Only

Page 7

OWNER’S MANUAL

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified ser- vice person must install heater. Follow all local codes.

NOTICE: State or local codes may only allow operation of this appli- ance in a vented configuration. Check your state or local codes.

WARNING: Make sure the selector switch is in the OFF po- sition before installing heater.

WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creo- sote, ashes and loose paint by a qualified chimney cleaner. Creo- sote will ignite if highly heated. A dirty chimney flue may create and distribute soot within the house. Inspect chimney flue for damage. If damaged, operate

WARNING: Seal any fresh air vents or ash clean-out doors lo- cated on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a heat- resistant sealant. Do not seal chimney flue damper.

WARNING: Never install the heater

in a bedroom or bathroom un- less installed as a vented ap- pliance, see page 10.

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the heater

in high traffic areas

in windy or drafty areas

CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as to- bacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls.

IMPORTANT: Vent-free heaters add mois- ture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Com- bustion and Ventilation, pages 4 through 6.

INSTALLATION AND

CLEARANCES

(Vent-Free Operation Only)

WARNING: Maintain the mini- mum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining wall.

MINIMUM FIREPLACE CLEARANCE

TO COMBUSTIBLE MATERIALS

Log Size Side Wall Ceiling Floor*

18" 24" 30"

16"

42"

5"

 

*See Floor Clearances, page 9.

 

 

 

 

 

 

 

 

LOG SIZING REQUIREMENTS

 

 

 

 

 

 

 

Minimum Firebox Size

Log

 

 

Front

Rear*

 

Size

Height

Depth

Width

Width

18"

17"

14"

20"

14"

 

24"

17"

14"

26"

18"

 

30"

17"

14"

32"

22"

 

 

 

 

 

 

 

*Measured at 14" depth

Carefully follow the instructions below. This will ensure safe installation into a masonry, UL127-listed manufactured fireplace, or listed vent-free firebox.

Minimum Wall and Ceiling Clearances (see Figure 4)

A.Clearances from the side of the fire- place opening to any combustible wall should not be less than 16 inches.

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

heater with flue damper closed.

CHECK GAS TYPE

42"

Use only natural gas. If your gas supply is not natural gas, do not install heater. Call dealer where you bought heater for proper type heater.

16"

Left and

Right Sides

Figure 4 - Minimum Clearance to Wall and

Ceiling

Continued

104416

7

Image 7
Contents What to do if YOU Smell GAS Desa InternationalDesa International Unvented Natural GAS LOG Heater Safety InformationUnpacking Product Identification FeaturesOptional Remote Control Accessories Local CodesConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside BuildingVent-Free Operation Only InstallationInstallation Clearances Check GAS TypeMinimum Noncombustible Material Clearances If Using MantelFloor Clearances Mantel ClearancesArea of Various Standard Round Flues Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededAttaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS SupplyPressure Testing gas Supply Piping system Pressure Testing Heater Gas ConnectionsChecking GAS Connections Installing Logs Operating Heater For Your Safety Read Before LightingLighting Instructions Shutting Off Burners Only pilot stays lit Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterGhrct Operation Optional Remote OperationThermostat Control Operation Ghrc OperationPilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern Replacement Parts Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingSee Wiring Diagram, Gas leak. See Warning statement Variable Control CFS18NRA, VS18NRA VS24NRA, VS30NRA Illustrated Parts BREAKDOWN4VS24NRA VS30NRA Description QTY Parts ListService Hints SpecificationsTechnical Service Wiring DiagramAccessories International Warranty Information

VS30NRA, VS18NRA, VS24NRA, CFS18NRA specifications

Desa, a well-known manufacturer in the heating and light industry, has developed several innovative products: the VS24NRA, VS30NRA, CFS18NRA, and VS18NRA. Each of these models showcases unique features, advanced technologies, and characteristics designed to cater to diverse consumer needs.

Starting with the VS24NRA, this unit is celebrated for its efficient heating capabilities. It boasts a powerful design, ideal for medium-sized spaces. Featuring an advanced combustion system, it ensures optimal fuel usage, translating to lower running costs and reduced environmental impact. The VS24NRA is equipped with an adjustable thermostat, allowing users to maintain desired temperatures easily. Its sleek and modern design allows it to fit seamlessly into various interior environments.

Next, the VS30NRA takes heating efficiency a step further. With a higher BTU output, it is suitable for larger spaces requiring more substantial heating solutions. This model incorporates cutting-edge heat distribution technology, ensuring even warmth throughout the room. Additionally, the VS30NRA is built with premium materials that enhance its durability, making it a long-term investment for homeowners. Its electronic ignition system contributes to convenience, allowing for quick and hassle-free startups.

The CFS18NRA stands out with its dual functionality by combining both heating and cooking capabilities. This model is ideal for those looking to maximize utility in smaller spaces. It features a contemporary design and compact build, making it an excellent addition to cabins, tiny homes, or other limited areas. The CFS18NRA utilizes infrared heating technology, which warms objects directly rather than relying solely on heating the air, creating a cozy atmosphere with minimal energy consumption.

Finally, the VS18NRA offers a balance between size and efficiency. It is tailored for modest environments, providing consistent warmth without overwhelming the space. The VS18NRA comes equipped with a user-friendly control panel, giving users precise control over settings. Its portability makes it a versatile choice for different rooms in a home or for outdoor gatherings.

In summary, Desa’s range, including the VS24NRA, VS30NRA, CFS18NRA, and VS18NRA, caters to a variety of heating needs. Their use of innovative technologies and emphasis on efficiency showcases Desa’s commitment to quality and customer satisfaction. Each model presents distinct features that make them suitable for a range of applications, ensuring homeowners can find the right solution for their heating needs.