Desa VS24NRA, CFS18NRA, VS18NRA, VS30NRA installation manual Gas leak. See Warning statement

Page 21

OWNER’S MANUAL

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces a clicking/ticking noise just after burners are lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most heaters. If noise is excessive, contact qualified ser- vice person

Heater produces unwanted odors

1.

Heater burning vapors from paint, hair

 

 

spray, glues, cleaners, chemicals, new

 

 

carpet, etc. (See IMPORTANT state-

 

 

ment above)

 

2.

Low fuel supply

 

3.

Gas leak. See Warning statement

 

 

above

1.Open window to ventilate room. Stop us- ing odor causing products while heater is running

2.Refill supply tank

3.Locate and correct all leaks (see Check- ing Gas Connections, page 12)

Heater shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Open window and/or door for ventilation

 

2.

Low line pressure

2.

Contact local natural gas company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 18)

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks (see Check-

position

 

above

 

ing Gas Connections, page 12)

 

2.

Gas control defective

2.

Replace gas control

Gas odor during combustion

1.

Foreign matter between control valve

 

 

and burner

 

2.

Gas leak. See Warning statement

 

 

above

1.Take apart gas tubing and remove for- eign matter

2.Locate and correct all leaks (see Check- ing Gas Connections, page 12)

Log set cycles to pilot, but room tempera- ture drops to a lower than ideal level before log set comes back on

1.Hand-held remote control unit needs to be moved away from heater

1.Move hand-held remote control unit far- ther away from the heater

www.desatech.com

104416

21

Image 21
Contents What to do if YOU Smell GAS Desa InternationalDesa International Unvented Natural GAS LOG Heater Safety InformationOptional Remote Control Accessories Product Identification FeaturesLocal Codes UnpackingProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsInstallation Clearances InstallationCheck GAS Type Vent-Free Operation OnlyMinimum Noncombustible Material Clearances If Using MantelFloor Clearances Mantel ClearancesInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Area of Various Standard Round FluesAttaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS SupplyPressure Testing Heater Gas Connections Pressure Testing gas Supply Piping systemChecking GAS Connections Installing Logs For Your Safety Read Before Lighting Operating HeaterLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureShutting Off Heater Shutting Off Burners Only pilot stays litThermostat Control Operation Optional Remote OperationGhrc Operation Ghrct OperationInspecting Burners Pilot Flame PatternFront Burner Flame Pattern Replacement Parts Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingSee Wiring Diagram, Gas leak. See Warning statement Variable Control CFS18NRA, VS18NRA VS24NRA, VS30NRA Illustrated Parts BREAKDOWN4VS24NRA VS30NRA Description QTY Parts ListTechnical Service SpecificationsWiring Diagram Service HintsAccessories International Warranty Information

VS30NRA, VS18NRA, VS24NRA, CFS18NRA specifications

Desa, a well-known manufacturer in the heating and light industry, has developed several innovative products: the VS24NRA, VS30NRA, CFS18NRA, and VS18NRA. Each of these models showcases unique features, advanced technologies, and characteristics designed to cater to diverse consumer needs.

Starting with the VS24NRA, this unit is celebrated for its efficient heating capabilities. It boasts a powerful design, ideal for medium-sized spaces. Featuring an advanced combustion system, it ensures optimal fuel usage, translating to lower running costs and reduced environmental impact. The VS24NRA is equipped with an adjustable thermostat, allowing users to maintain desired temperatures easily. Its sleek and modern design allows it to fit seamlessly into various interior environments.

Next, the VS30NRA takes heating efficiency a step further. With a higher BTU output, it is suitable for larger spaces requiring more substantial heating solutions. This model incorporates cutting-edge heat distribution technology, ensuring even warmth throughout the room. Additionally, the VS30NRA is built with premium materials that enhance its durability, making it a long-term investment for homeowners. Its electronic ignition system contributes to convenience, allowing for quick and hassle-free startups.

The CFS18NRA stands out with its dual functionality by combining both heating and cooking capabilities. This model is ideal for those looking to maximize utility in smaller spaces. It features a contemporary design and compact build, making it an excellent addition to cabins, tiny homes, or other limited areas. The CFS18NRA utilizes infrared heating technology, which warms objects directly rather than relying solely on heating the air, creating a cozy atmosphere with minimal energy consumption.

Finally, the VS18NRA offers a balance between size and efficiency. It is tailored for modest environments, providing consistent warmth without overwhelming the space. The VS18NRA comes equipped with a user-friendly control panel, giving users precise control over settings. Its portability makes it a versatile choice for different rooms in a home or for outdoor gatherings.

In summary, Desa’s range, including the VS24NRA, VS30NRA, CFS18NRA, and VS18NRA, caters to a variety of heating needs. Their use of innovative technologies and emphasis on efficiency showcases Desa’s commitment to quality and customer satisfaction. Each model presents distinct features that make them suitable for a range of applications, ensuring homeowners can find the right solution for their heating needs.