Desa BQMV24N NOTICE Do not mistake orange, flames with yellow tipping. Dirt, by appliance, shown

Page 11
Knob for Remote Operation

OPERATING APPLIANCE

Continued

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions on page 10.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON posi- tion. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 13). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

Control Knob

ON/OFF SERIES (MODEL GHRCB) REMOTE

OFF

ON

 

Flame

Selector Switch in

Piezo

REMOTE Position

Adjustment

 

Ignitor

 

Knob

 

 

 

Figure 13 - Setting the Selector Switch,

Control Knob and Flame Adjustment

Knob for Remote Operation

ON/OFF SERIES (MODEL GHRCB)

Hold the control button on the hand-held remote

until burner turns on. Hold the control button

again until burner turns off (see Figure 14).

To Lock press both buttons on hand-held

remote control until light stops flashing. Hand-

held remote control is now locked. If the fire is

on it will be turned off automatically. In the

locked state, the light will not light up when

any button is pressed.

 

Indicator

 

Light

 

 

 

 

Control

 

 

Button

To Unlock press both buttons together on hand- held remote control until the light stops flashing. The hand-held remote is now unlocked.

INSPECTING BURNERS

Check pilot flame pattern and burner flame pat- terns often.

PILOT FLAME PATTERN

You can view the pilot light through the pilot viewing hole on the pilot bracket. This is located under the front grate bar on the right side of the log set.

Figure 15 shows a correct pilot flame pattern. Figure 16 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the ther- mocouple. This will cause the thermocouple to cool. When the thermocouple cools, the appliance will shut down.

If pilot flame pattern is incorrect, as shown in Figure 16

turn appliance off (see To Turn Off Gas to Appliance, page 10)

see Troubleshooting, page 13

Note: The pilot flame on natural gas units will

have a slight curve but flames should be blue and

have no yellow or orange color.
Thermocouple

Figure 15 - Correct

Figure 16 -

Pilot Flame Pattern

Incorrect Pilot

(Your pilot may

Flame Pattern

vary from pilots

(Your pilot may

shown)

vary from pilots

 

shown)

BURNER FLAME PATTERN

Figure 17 shows correct burner flame pattern.

NOTICE: Do not mistake orange

flames with yellow tipping. Dirt

or other fine particles are burned

by appliance,

causing brief

patches of orange flame.

 

Yellow Flames

 

with Orange

 

Streaks

Figure 14 - On/Off Hand-Held Remote Control Unit (HRC100)

Figure 17 - Correct Burner Flame Pattern

117423-01A

www.desatech.com

11

Image 11
Contents WHAT TO DO IF YOU SMELL GAS TABLE OF CONTENTS SAFETY INFORMATION Continued SAFETY INFORMATIONLOCAL CODES UNPACKING PRODUCT FEATURESINSTALLATION PRODUCT IDENTIFICATIONINSTALLATION INSTALLATION AND CLEARANCESFLUE OPENING SPECIFICATIONS VENTING SPECIFICATIONS FORInstallation Items Needed INSTALLING APPLIANCECONNECTING TO GAS SUPPLY CHECKING GAS CONNECTIONS Continued PLACEMENT OF LOOSE EMBERSPressure Testing Appliance Gas Connections Figure 11 - Placement of EmbersTO APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS TO TURN OFF GASflames with yellow tipping. Dirt causing briefsee Troubleshooting, page NOTICE Do not mistake orangeWhen Gas Pressure is Too Low PARTS UNDER WARRANTYPARTS NOT UNDER WARRANTY see Troubleshooting, pageREMEDY TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEREMEDY OBSERVED PROBLEM POSSIBLE CAUSESee Wiring Diagram, page ContinuedPOSSIBLE CAUSE OBSERVED PROBLEMMaintenance, page ContinuedWARNING If you smell gas Shut off gas supply EQUIPMENT SHUTOFF VALVE GA5010 RECEIVER AND HAND-HELDREMOTE CONTROL KIT - HRCCLEANING KIT - GCK When Using Remote117423-01A MODELS BQMV24N, BQMV24P, BQMV18N AND BQMV18P9 8 6 5 3 PARTS LIST LIMITED WARRANTY VENTED GAS LOG APPLIANCES WARRANTY INFORMATIONKEEP THIS WARRANTY