Desa BQMV24P EQUIPMENT SHUTOFF VALVE GA5010, LAVA ROCK - GA6060, Cleaning Kit - Gck, BQMV18N

Page 17
BQMV18N

SPECIFICATIONS

This appliance has been design certified to ANSI ZZ1.60-2003and CSA 2.26-2003 Decorative Gas Appliances for Installation in Solid Fuel Burning Fireplaces by OMNI Test Laboratories.

 

BQMV18N

BQMV18P

BQMV24N

BQMV24P

Btu (Variable)

36,000/53,000

35,000/45,000

36,000/53,000

35,000/45,000

Type Gas

Natural Gas Only

Propane/LP Only

Natural Gas Only

Propane/LP Only

Ignition

Piezo

Piezo

Piezo

Piezo

Manifold Pressure

3.5" W.C.

10" W.C.

3.5" W.C.

10" W.C.

Inlet Gas Pressure (in. of water)

 

 

 

Maximum

10.5" W.C.

14" W.C.

10.5" W.C.

14" W.C.

Minimum*

5.0" W.C.

11" W.C.

5.0" W.C.

11" W.C.

* For purpose of input adjustment

ACCESSORIES

Purchase these appliances from your local dealer. If they can not supply these accessories, call DESA at 1-866-672-6040 for referral information. You can also write to the address listed on the back page of this manual.

EQUIPMENT SHUTOFF VALVE GA5010

Equipment shutoff valve with 1/8" NPT tap. Fits 1/2" pipe.

LAVA ROCK - GA6060

(Not Shown)

Order when additional rock is desired (1.8 lb. bag)

RECEIVER AND HAND-HELD REMOTE CONTROL KIT - HRC 100

Allows the log set to be turned on and off by using a hand-held remote control. A wall-mount docking station is included.

CLEANING KIT - GCK

(Not Shown)

Your vented gas appliance requires regular cleaning and maintenance to prevent performance problems. This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance.

FIREPLACE HOOD

Black - GA6050

Brass - GA6052

Antique Brass - GA6053

Helps deflect heat away from mantel or wall above fireplace. Fits opening 28" to 48" wide.

DAMPER CLAMP - GA6080

(Not Shown)

Permanently opens chimney flue damper for vented operation.

WIRING DIAGRAM

When Using Remote

To Remote

Receiver

Thermopile

117423-01A

www.desatech.com

17

Image 17
Contents WHAT TO DO IF YOU SMELL GAS TABLE OF CONTENTS SAFETY INFORMATION Continued SAFETY INFORMATIONLOCAL CODES INSTALLATION PRODUCT FEATURESPRODUCT IDENTIFICATION UNPACKINGFLUE OPENING SPECIFICATIONS INSTALLATION AND CLEARANCESVENTING SPECIFICATIONS FOR INSTALLATIONInstallation Items Needed INSTALLING APPLIANCECONNECTING TO GAS SUPPLY CHECKING GAS CONNECTIONS Pressure Testing Appliance Gas Connections PLACEMENT OF LOOSE EMBERSFigure 11 - Placement of Embers ContinuedLIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTINGTO TURN OFF GAS TO APPLIANCEsee Troubleshooting, page causing briefNOTICE Do not mistake orange flames with yellow tipping. DirtPARTS NOT UNDER WARRANTY PARTS UNDER WARRANTYsee Troubleshooting, page When Gas Pressure is Too LowOBSERVED PROBLEM TROUBLESHOOTINGPOSSIBLE CAUSE REMEDYSee Wiring Diagram, page OBSERVED PROBLEM POSSIBLE CAUSEContinued REMEDYMaintenance, page OBSERVED PROBLEMContinued POSSIBLE CAUSEWARNING If you smell gas Shut off gas supply CLEANING KIT - GCK RECEIVER AND HAND-HELDREMOTE CONTROL KIT - HRCWhen Using Remote EQUIPMENT SHUTOFF VALVE GA5010117423-01A MODELS BQMV24N, BQMV24P, BQMV18N AND BQMV18P9 8 6 5 3 PARTS LIST LIMITED WARRANTY VENTED GAS LOG APPLIANCES WARRANTY INFORMATIONKEEP THIS WARRANTY