Desa LSL3124N Thermostat Control Operation, Operating Heater, Continued, Shutting Off Heater

Page 17
THERMOSTAT

OPERATING HEATER (THERMOSTAT MODELS)

Lighting Instructions (Cont.)

To Turn Off Gas To Appliance

Thermostat Control Operation

Manual Lighting Procedure

17

OPERATING HEATER

Continued

1.STOP! Read the safety information in column 2, page 16.

2.Make sure equipment shutoff valve is fully open.

3. Turn control knob clockwise ClockwiseFor morevisit www..com to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information in column 2, page 16. If you don’t smell gas, go to the next step.

5. Turn control knob counterclockwise Manual backgroundC-clockwiseto the PILOT position. Press in control knob for five (5) seconds (see Fig- ure 25).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure .

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for sys- tem to reset before lighting pilot again.

8. Turn control knob counterclockwise Manual backgroundC-clockwiseto desired heating level. The burners should light. Set control knob to any heat level between HI and LO.

Manual background CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

 

 

Ignitor

 

Pilot

Button

 

HI

 

OL

OFF

 

Control Knob

Figure 25 - Control Knob and Ignitor Button Location

Ignitor Electrode

Thermocouple

Pilot Burner

Figure 26 - Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise ClockwiseManual background to the OFF position.

Shutting Off Burners Only (pilot stays lit)

Turn control knob clockwise ClockwiseManual background to the PILOT position.

THERMOSTAT

CONTROL OPERATION

The thermostat control knob can be set to any comfort level between HI and LO. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

Note: Selecting the HI setting with the control knob will cause the burners to remain fully on, without modulating down in most cases.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions, column 1.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 under Lighting Instructions, column 1.

For moreManual backgroundManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

111347-01B

Image 17
Contents Do not try to light any appliance UNVENTED VENT-FREE GAS LOG HEATERWHAT TO DO IF YOU SMELL GAS WARNINGS TABLE OF CONTENTSSAFETY INFORMATION UNPACKING LOCAL CODESContinued SAFETY INFORMATIONSAFETY DEVICE PRODUCT FEATURESPRODUCT IDENTIFICATION AIR FOR COMBUSTION AND VENTILATIONDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION PROVIDING ADEQUATE VENTILATIONUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Inside Building VENTILATION AIRVentilation Air From Outdoors AIR FOR COMBUSTION AND VENTILATIONCHECK GAS TYPE INSTALLATIONMINIMUM FIREPLACE CLEARANCE TO COMBUSTIBLE MATERIALSINSTALLATION Minimum Noncombustible Material ClearancesSafe Installation ContinuedFLOOR CLEARANCES MANTEL CLEARANCESDetermining Minimum Mantel Clearance INSTALLATIONInstallation Items Needed INSTALLING HEATER BASE ASSEMBLYArea of Various Standard Round Flues INSTALLATIONINSTALLATION CONNECTING TO GAS SUPPLYInstallation Items Needed ContinuedPressure Testing Heater Gas Connections Pressure Testing gas Supply Piping systemCHECKING GAS CONNECTIONS INSTALLATIONVariable Manually-ControlledModels LSL INSTALLING LOGSINSTALLATION ContinuedOPERATING HEATER MANUALLY-CONTROLLEDMODELS FOR YOUR SAFETYREAD BEFORE LIGHTING LIGHTING INSTRUCTIONSContinued VARIABLE CONTROL OPERATIONOPERATING HEATER THERMOSTAT MODELS FOR YOUR SAFETY READ MANUAL LIGHTING PROCEDURETO TURN OFF GAS TO APPLIANCE BEFORE LIGHTINGMANUAL LIGHTING PROCEDURE THERMOSTAT CONTROL OPERATIONOPERATING HEATER ContinuedINSPECTING BURNERS CLEANING AND MAINTENANCEPILOT FLAME PATTERN BURNER PRIMARY AIR HOLESLOGS SPECIFICATIONSCLEANING AND MAINTENANCE ContinuedOBSERVED PROBLEM TROUBLESHOOTINGPOSSIBLE CAUSE REMEDYvisit www For moreRefer to Air for Combustion and Venti TROUBLESHOOTINGTROUBLESHOOTING ing Gas Connections, pages 12 andOBSERVED PROBLEM ContinuedFor Masonry and Factory-BuiltMetal Fireplace OPTIONAL POSITIONING OF THERMOSTAT SENSING BULBVARIABLE MANUALLY- CONTROLLED ILLUSTRATED PARTS BREAKDOWNECHO VALLEY OAK LOG MODELS LSL3124N, LSL3124P 3 - ODS PilotVARIABLE MANUALLY-CONTROLLED PARTS LISTECHO VALLEY OAK LOG MODELS PARTS LISTMEADOWBROOK OAK LOG MODELS CDL3924NT, CDL3924PT THERMOSTATICALLY- CONTROLLEDILLUSTRATED PARTS BREAKDOWN ILLUSTRATED PARTS BREAKDOWNPARTS LIST THERMOSTATICALLY- CONTROLLED MEADOWBROOK OAK LOGPARTS LIST PART NUMBER FORSERVICE HINTS ACCESSORIESTECHNICAL SERVICE REPLACEMENT PARTSOWNERS REGISTRATION FORM 2701 Industrial Drive P.O. Box Bowling Green, KY Postage RequiredTAPE TAPEPage LIMITED WARRANTY VENT-FREEGAS LOG HEATERS WARRANTY INFORMATIONNOT A UPC Model Serial No Date Purchased