Desa LSL3124N Parts List, Variable Manually-Controlled, Echo Valley Oak Log Models, LSL3124P

Page 25
PARTS LIST

PARTS LIST

Models LSL3124N and LSL3124P

25

PARTS LIST

VARIABLE MANUALLY-CONTROLLED

ECHO VALLEY OAK LOG MODELS

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 28 of this manual.

KEY

PART NUMBER FOR

 

 

NO.

LSL3124PLSL3124NDESCRIPTION

QTY.

1

**

**

ASM, Low Profile Base, Painted

1

2

102773-01

102773-01

Single Burner, 24"

1

3

104286-01

ODS Pilot, Propane/LP Gas

1

 

104285-01

ODS Pilot, Natural Gas

1

4

102568-08

Control Valve, Propane/LP Gas

1

 

102568-07

Control Valve, Natural Gas

1

5

098354-01

098354-01

Control Knob

1

6

098276-01

098276-01

Plug, 1/8" NPT Hex Head

1

7

098508-01

098508-01

Valve Retainer Nut

1

8

098462-03

098462-03

Control Rod

1

9

098325-01

098325-01

Roll Pin

1

10

110801-01

110801-01

Inlet Tube

1

11

110802-06

111195-01

Outlet Tube

1

12

098867-10

Gas Regulator, Propane/LP Gas

1

 

098867-14

Gas Regulator, Natural Gas

1

13

099387-08

099387-08

Pilot Tube

1

14

099056-31

099056-26

Injector

1

15

110790-01

110790-01

Left Front Burner Bracket

1

16

110790-02

110790-02

Right Front Burner Bracket

1

17

110793-01

110793-01

Piezo Bracket

1

18

110817-01

110817-01

Control Rod Bracket

1

19

110791-01

110791-01

Manual Valve Bracket

1

20

110902-01

110902-01

Log Support Bracket

2

21

102445-01

102445-01

Piezo Ignitor

1

22

102334-01

102334-01

Palnut Fastener

1

23

098271-10

098271-10

Ignitor Cable

1

24

111124-01

111124-01

Burner Retainer Spring

1

25

M11084-26

M11084-26

Screw, HWH AB 10-16 x .38

18

26

M11084-38

M11084-38

Screw, Hex Head Tpg 8-18 x .38

2

27

098249-01

098249-01

O.D.S. Nut

2

28-1

111501-01

111501-01

Left Front Log

1

28-2

111501-02

111501-02

Right Front Log

1

28-3

111501-03

111501-03

Control Cover Log

1

28-4

111501-04

111501-04

Back Log

1

28-5

111501-05

111501-05

Left Crossover Log

1

 

 

 

 

 

 

 

PARTS AVAILABLE — NOT SHOWN

 

 

 

 

 

 

 

100563-01

100563-01

Warning Plate

1

 

101055-02

101055-02

Lighting Instruction Plate

1

 

GA6060

GA6060

Lava Rock

1

 

101137-02

101137-02

Hardware Kit

1

 

 

 

 

 

**Not a field replaceable part.

VARIABLE MANUALLY-CONTROLLEDFor moreECHO VALLEY OAK LOG MODELSPART NUMBER FORLSL3124PLSL3124Nvisit www.DESCRIPTIONPARTS AVAILABLE — NOT SHOWNManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

111347-01B

Image 25
Contents WHAT TO DO IF YOU SMELL GAS UNVENTED VENT-FREE GAS LOG HEATERDo not try to light any appliance SAFETY INFORMATION TABLE OF CONTENTSWARNINGS UNPACKING LOCAL CODESContinued SAFETY INFORMATIONSAFETY DEVICE PRODUCT FEATURESPRODUCT IDENTIFICATION AIR FOR COMBUSTION AND VENTILATIONDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION PROVIDING ADEQUATE VENTILATIONUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Inside Building VENTILATION AIRVentilation Air From Outdoors AIR FOR COMBUSTION AND VENTILATIONCHECK GAS TYPE INSTALLATIONMINIMUM FIREPLACE CLEARANCE TO COMBUSTIBLE MATERIALSINSTALLATION Minimum Noncombustible Material ClearancesSafe Installation ContinuedFLOOR CLEARANCES MANTEL CLEARANCESDetermining Minimum Mantel Clearance INSTALLATIONInstallation Items Needed INSTALLING HEATER BASE ASSEMBLYArea of Various Standard Round Flues INSTALLATIONINSTALLATION CONNECTING TO GAS SUPPLYInstallation Items Needed ContinuedPressure Testing Heater Gas Connections Pressure Testing gas Supply Piping systemCHECKING GAS CONNECTIONS INSTALLATIONVariable Manually-ControlledModels LSL INSTALLING LOGSINSTALLATION ContinuedOPERATING HEATER MANUALLY-CONTROLLEDMODELS FOR YOUR SAFETYREAD BEFORE LIGHTING LIGHTING INSTRUCTIONSOPERATING HEATER VARIABLE CONTROL OPERATIONContinued THERMOSTAT MODELS FOR YOUR SAFETY READ MANUAL LIGHTING PROCEDURETO TURN OFF GAS TO APPLIANCE BEFORE LIGHTINGMANUAL LIGHTING PROCEDURE THERMOSTAT CONTROL OPERATIONOPERATING HEATER ContinuedINSPECTING BURNERS CLEANING AND MAINTENANCEPILOT FLAME PATTERN BURNER PRIMARY AIR HOLESLOGS SPECIFICATIONSCLEANING AND MAINTENANCE ContinuedOBSERVED PROBLEM TROUBLESHOOTINGPOSSIBLE CAUSE REMEDYvisit www For moreRefer to Air for Combustion and Venti TROUBLESHOOTINGTROUBLESHOOTING ing Gas Connections, pages 12 andOBSERVED PROBLEM ContinuedFor Masonry and Factory-BuiltMetal Fireplace OPTIONAL POSITIONING OF THERMOSTAT SENSING BULBVARIABLE MANUALLY- CONTROLLED ILLUSTRATED PARTS BREAKDOWNECHO VALLEY OAK LOG MODELS LSL3124N, LSL3124P 3 - ODS PilotVARIABLE MANUALLY-CONTROLLED PARTS LISTECHO VALLEY OAK LOG MODELS PARTS LISTMEADOWBROOK OAK LOG MODELS CDL3924NT, CDL3924PT THERMOSTATICALLY- CONTROLLEDILLUSTRATED PARTS BREAKDOWN ILLUSTRATED PARTS BREAKDOWNPARTS LIST THERMOSTATICALLY- CONTROLLED MEADOWBROOK OAK LOGPARTS LIST PART NUMBER FORSERVICE HINTS ACCESSORIESTECHNICAL SERVICE REPLACEMENT PARTSOWNERS REGISTRATION FORM 2701 Industrial Drive P.O. Box Bowling Green, KY Postage RequiredTAPE TAPEPage LIMITED WARRANTY VENT-FREEGAS LOG HEATERS WARRANTY INFORMATIONNOT A UPC Model Serial No Date Purchased