SPECIFICATIONS

CLEANING AND MAINTENANCE

Cleaning Burner Injector Holder and Pilot Air Inlet Hole (Cont.) Logs

SPECIFICATIONS

19

CLEANING AND

MAINTENANCE

Continued

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 30). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

SPECIFICATIONS

 

Echo Valley Oak Log

 

Variable Manually-Controlled

Btu (Variable)

16,000/31,500

Type Gas

Propane/LP - Natural

Ignition

Piezo

Manifold Pressure

8.0" W.C. - 3.5" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

14" - 10.5"

Burner Tube

Primary Air Inlet Holes (Shape of Holes May Vary by Model)

Injector Holder (May Be Brass or Aluminum Depending on Model)

Minimum*

11" - 5"

Shipping Weight

38 lbs.

* For purpose of input adjustment

 

Meadowbrook Oak Log

 

Thermostatically-Controlled

Btu (Variable)

26,000/39,000

Type Gas

Propane/LP - Natural

Ignition

Piezo

Manifold Pressure

8.0" W.C. - 3.5" W.C.

Figure 29 - Injector Holder On Outlet Burner Tube

Ports/Slots

Burner Tube

Pilot Assembly

Pilot Air

Inlet Hole

Figure 30 - Pilot Inlet Air Hole

LOGS

If you remove logs for cleaning, refer to Installing Logs, pages 13 and 14, to properly replace logs.

Replace log(s) if broken or chipped (dime-sized or larger).

Inlet Gas Pressure (in. of water)

 

Maximum

14" - 10.5"

Minimum*

11" - 5"

Shipping Weight

28 lbs.

* For purpose of input adjustment

For moreLOGSManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

111347-01B

Image 19
Contents WHAT TO DO IF YOU SMELL GAS UNVENTED VENT-FREE GAS LOG HEATERDo not try to light any appliance SAFETY INFORMATION TABLE OF CONTENTSWARNINGS SAFETY INFORMATION LOCAL CODESUNPACKING ContinuedAIR FOR COMBUSTION AND VENTILATION PRODUCT FEATURESSAFETY DEVICE PRODUCT IDENTIFICATIONConfined and Unconfined Space PROVIDING ADEQUATE VENTILATIONDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION Unusually Tight ConstructionAIR FOR COMBUSTION AND VENTILATION VENTILATION AIRVentilation Air From Inside Building Ventilation Air From OutdoorsCOMBUSTIBLE MATERIALS INSTALLATIONCHECK GAS TYPE MINIMUM FIREPLACE CLEARANCE TOContinued Minimum Noncombustible Material ClearancesINSTALLATION Safe InstallationINSTALLATION MANTEL CLEARANCESFLOOR CLEARANCES Determining Minimum Mantel ClearanceINSTALLATION INSTALLING HEATER BASE ASSEMBLYInstallation Items Needed Area of Various Standard Round FluesContinued CONNECTING TO GAS SUPPLYINSTALLATION Installation Items NeededINSTALLATION Pressure Testing gas Supply Piping systemPressure Testing Heater Gas Connections CHECKING GAS CONNECTIONSContinued INSTALLING LOGSVariable Manually-ControlledModels LSL INSTALLATIONLIGHTING INSTRUCTIONS MANUALLY-CONTROLLEDMODELS FOR YOUR SAFETYOPERATING HEATER READ BEFORE LIGHTINGOPERATING HEATER VARIABLE CONTROL OPERATIONContinued BEFORE LIGHTING MANUAL LIGHTING PROCEDURETHERMOSTAT MODELS FOR YOUR SAFETY READ TO TURN OFF GAS TO APPLIANCEContinued THERMOSTAT CONTROL OPERATIONMANUAL LIGHTING PROCEDURE OPERATING HEATERBURNER PRIMARY AIR HOLES CLEANING AND MAINTENANCEINSPECTING BURNERS PILOT FLAME PATTERNContinued SPECIFICATIONSLOGS CLEANING AND MAINTENANCEREMEDY TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSETROUBLESHOOTING For morevisit www Refer to Air for Combustion and VentiContinued ing Gas Connections, pages 12 andTROUBLESHOOTING OBSERVED PROBLEMFor Masonry and Factory-BuiltMetal Fireplace OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB3 - ODS Pilot ILLUSTRATED PARTS BREAKDOWNVARIABLE MANUALLY- CONTROLLED ECHO VALLEY OAK LOG MODELS LSL3124N, LSL3124PPARTS LIST PARTS LISTVARIABLE MANUALLY-CONTROLLED ECHO VALLEY OAK LOG MODELSILLUSTRATED PARTS BREAKDOWN THERMOSTATICALLY- CONTROLLEDMEADOWBROOK OAK LOG MODELS CDL3924NT, CDL3924PT ILLUSTRATED PARTS BREAKDOWNPART NUMBER FOR THERMOSTATICALLY- CONTROLLED MEADOWBROOK OAK LOGPARTS LIST PARTS LISTREPLACEMENT PARTS ACCESSORIESSERVICE HINTS TECHNICAL SERVICEOWNERS REGISTRATION FORM TAPE Postage Required2701 Industrial Drive P.O. Box Bowling Green, KY TAPEPage Model Serial No Date Purchased WARRANTY INFORMATIONLIMITED WARRANTY VENT-FREEGAS LOG HEATERS NOT A UPC