Desa LSL3124N installation manual Optional Positioning Of Thermostat Sensing Bulb

Page 23
OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB

OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB

23

OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB

For Masonry and Factory-Built Metal Fireplace

If your log set cycles to pilot, but the room temperature drops to a lower than ideal comfort level before the log set comes back on, you may want to reposition the thermostat sensing bulb.

The thermostat sensing bulb is located near the gas valve assembly on the mounting bracket. This location allows the thermostat to keep the room temperature at an ideal comfort level for most fireplace applications. For positioning the thermostat sensing bulb else- where, an adhesive-backed mounting clip is available.

Tools needed: 1/4" hex driver or socket

1.

Remove logs. Locate the gas valve assembly and thermostat

 

sensing bulb (see Figure 31).

2.

With 1/4" hex driver or socket, loosen the thermostat screw.

 

Carefully slide the thermostat sensing bulb out of the retaining

 

clamp (see Figure 33).

Figure 32 - Adhesive-backed Mounting Clip

Capillary

Thermostat

Sensing Bulb

Retaining Thermostat

Clamp Screw

Figure 33 - Removing Thermostat Sensing Bulb

Note: Do not remove the screw. Make sure you tighten the

screw after removing the thermostat sensing bulb.

IMPORTANT: Do not force or bend the thermostat sensing

bulb or capillary.

3. The thermostat sensing bulb may be located to the lower right

front side of fireplace. Determine location of sensing bulb, but

do not mount sensing bulb until step 5. If you have a masonry

fireplace, see Figure 34 for location. If you have a factory-

built metal fireplace, see Figure 35 for location. If your fire-

place has glass doors, position sensing bulb directly behind

Thermostat For Masonry and Factory-Built Metal Fireplace

Sensing

Bulb

Adhesive-

Backed

Mounting

Clip

Thermostat

Sensing

Bulb

Adhesive-

Backed

MountingManual background

Clip

door gap on right bottom side (see Figure 36).

4. The mounting clip must be a minimum of 3" from bottom of

fireplace to prevent crimping of capillary. Once you have de-

Figure 34 - Locating

Figure 35 - Locating Thermostat

Thermostat Sensing Bulb on

Sensing Bulb on Factory-built

Masonry Fireplace

Metal Fireplace

cided on a location, clean the area thoroughly. Remove the pa-

per backing from the adhesive on back of mounting clip. Press

the clip into the new location so that the thermostat sensing bulb

will be positioned vertically with the capillary at the bottom

(see Figure 37). Slide the thermostat sensing bulb into the clip.

IMPORTANT: Do not crimp capillary.

Thermostat

Sensing

Bulb

Adhesive- Manual background backed Mounting Manual backgroundManual background Clip

Thermostat

Sensing Bulb

Adhesive-

Manual background backed

Capillary Mounting

Clip

 

Do Not

 

Crimp

Glass Doors

Capillary

 

Figure 36 - Installing Figure 37 - Positioning the Thermostat Sensing Bulb Thermostat Sensing Bulb in

behind Glass Doorsthe Vertical Position with the Capillary at the Bottom

Gas Valve

AssemblyThermostat

Sensing Bulb

Figure 31 - Location of Gas Valve Assembly and Thermostat

Sensing Bulb

Manual backgroundFor moreManual backgroundManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

111347-01B

Image 23
Contents Do not try to light any appliance UNVENTED VENT-FREE GAS LOG HEATERWHAT TO DO IF YOU SMELL GAS WARNINGS TABLE OF CONTENTSSAFETY INFORMATION SAFETY INFORMATION LOCAL CODESUNPACKING ContinuedAIR FOR COMBUSTION AND VENTILATION PRODUCT FEATURESSAFETY DEVICE PRODUCT IDENTIFICATIONConfined and Unconfined Space PROVIDING ADEQUATE VENTILATIONDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION Unusually Tight ConstructionAIR FOR COMBUSTION AND VENTILATION VENTILATION AIRVentilation Air From Inside Building Ventilation Air From OutdoorsCOMBUSTIBLE MATERIALS INSTALLATIONCHECK GAS TYPE MINIMUM FIREPLACE CLEARANCE TOContinued Minimum Noncombustible Material ClearancesINSTALLATION Safe InstallationINSTALLATION MANTEL CLEARANCESFLOOR CLEARANCES Determining Minimum Mantel ClearanceINSTALLATION INSTALLING HEATER BASE ASSEMBLYInstallation Items Needed Area of Various Standard Round FluesContinued CONNECTING TO GAS SUPPLYINSTALLATION Installation Items NeededINSTALLATION Pressure Testing gas Supply Piping systemPressure Testing Heater Gas Connections CHECKING GAS CONNECTIONSContinued INSTALLING LOGSVariable Manually-ControlledModels LSL INSTALLATIONLIGHTING INSTRUCTIONS MANUALLY-CONTROLLEDMODELS FOR YOUR SAFETYOPERATING HEATER READ BEFORE LIGHTINGContinued VARIABLE CONTROL OPERATIONOPERATING HEATER BEFORE LIGHTING MANUAL LIGHTING PROCEDURETHERMOSTAT MODELS FOR YOUR SAFETY READ TO TURN OFF GAS TO APPLIANCEContinued THERMOSTAT CONTROL OPERATIONMANUAL LIGHTING PROCEDURE OPERATING HEATERBURNER PRIMARY AIR HOLES CLEANING AND MAINTENANCEINSPECTING BURNERS PILOT FLAME PATTERNContinued SPECIFICATIONSLOGS CLEANING AND MAINTENANCEREMEDY TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSETROUBLESHOOTING For morevisit www Refer to Air for Combustion and VentiContinued ing Gas Connections, pages 12 andTROUBLESHOOTING OBSERVED PROBLEMFor Masonry and Factory-BuiltMetal Fireplace OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB3 - ODS Pilot ILLUSTRATED PARTS BREAKDOWNVARIABLE MANUALLY- CONTROLLED ECHO VALLEY OAK LOG MODELS LSL3124N, LSL3124PPARTS LIST PARTS LISTVARIABLE MANUALLY-CONTROLLED ECHO VALLEY OAK LOG MODELSILLUSTRATED PARTS BREAKDOWN THERMOSTATICALLY- CONTROLLEDMEADOWBROOK OAK LOG MODELS CDL3924NT, CDL3924PT ILLUSTRATED PARTS BREAKDOWNPART NUMBER FOR THERMOSTATICALLY- CONTROLLED MEADOWBROOK OAK LOGPARTS LIST PARTS LISTREPLACEMENT PARTS ACCESSORIESSERVICE HINTS TECHNICAL SERVICEOWNERS REGISTRATION FORM TAPE Postage Required2701 Industrial Drive P.O. Box Bowling Green, KY TAPEPage Model Serial No Date Purchased WARRANTY INFORMATIONLIMITED WARRANTY VENT-FREEGAS LOG HEATERS NOT A UPC