Desa SBLP375AT, 375-F owner manual Storage, Maintenance, To Stop Heater, To Restart Heater

Page 6

OPERATION

Continued

5.Open propane/LP supply valve on propane/LP tank(s) slowly. Note: If not opened slowly, ex- cess-flow check valve on propane/LP tank will stop gas flow. If this happens, you may hear a click inside the regulator assembly. To reset the excess flow check valve, close propane/LP supply valve and open again slowly.

6.Make sure regulator is set between 7 and 20 psig. Note: Higher regulator setting will allow heater to produce more heat.

7.Turn on/off switch to the ON position. Adjust thermostat to desired setting. If heater does not start, thermostat setting may be too low. Turn thermostat knob to higher position to start heater. Note: If heater does not start, turn on/off switch to the OFF position. Wait ten seconds for safety control to reset, then try again.

TO STOP HEATER

1.Tightly close propane/LP supply valve on propane tank(s).

2.Wait a few seconds. Heater will burn gas left in supply hoses.

3.Turn on/off switch to the OFF position.

4.Unplug heater.

TO RESTART HEATER

If safety control stops gas flow to heater, motor will continue to run.

1.Turn on/off switch to the OFF position.

2.Wait ten seconds, then turn on/off switch to the ON position.

If heater does not restart

1.Check manual valves (if any) and supply valves (on propane/LP tank). Make sure they are open.

2.Check fuel level in propane/LP tank(s). If fuel level is too low, contact local propane/LP gas company.

If heater still does not restart, contact your local service center.

STORAGE

CAUTION:Disconnectheater from propane supply tank(s).

1.Store propane/LP tank(s) in safe manner. See chapter 5 of Standard for Storage and Handling of Liquefied Petroleum Gases, ANSI/ NFPA 58 and the Propane Installation Code CAN/CGA B149.2. Follow all local codes.

2.Place plastic cover caps over brass fittings on inlet connector and hose/regulator assembly.

3.Store in dry, clean and safe place. Do not store hose/regulator assembly inside heater combustion chamber.

4.When taking heater out of storage, always check inside of heater. Insects and small animals may place foreign objects in heater. Keep inside of heater free from combustible and foreign objects.

MAINTENANCE

WARNING: Never service heater while it is plugged in, connected to propane supply, operating or hot. Severe burns and electrical shock can occur.

1.Keep heater clean. Clean heater annually or as needed to remove dust and debris. If heater is dirty or dusty, clean heater with a damp cloth.

2.Inspect heater before each use. Check connec- tions for leaks. Apply mixture of liquid soap and water to connections. Bubbles forming show a leak. Correct all leaks at once.

3.Inspect hose/regulator assembly before each use. If hose is highly worn or cut, replace.

4.Have heater inspected yearly by a qualified service agency.

5.Keep inside of heater free from combustible and foreign objects.

6

www.desatech.com

116699-01B

Image 6
Contents PROPANE/LP Construction Forced AIR Heater Models BLP375AT, SBLP375AT and 375-FTable of Contents Safety InformationProduct Identification UnpackingDo not use heater outdoors or in occupied dwellings Amount of propane/LP gas in the tanks Temperature of tanks Propane SupplyTo Start Heater InstallationOperation Provide propane/LP supply system see Pro- pane/LP Supply,To Stop Heater MaintenanceStorage To Restart HeaterService Procedures Cleaning FANSpecifications AccessoriesTechnical Service Parts Under Warranty Wiring DiagramsReplacement Parts Parts not Under WarrantyIllustrated Parts Breakdown Parts List Warranty and Repair Service Keep this WarrantyModelos BLP375AT, SBLP375AT Y 375-F Tabla DE Contenido Información DE SeguridadIdentificación DEL Producto DesempaqueSaque todos los elementos de la caja Teoría DEL Funcionamiento VentilaciónInstalación FuncionamientoPara Encender EL Calentador Para Apagar EL Calentador AlmacenamientoMantenimiento Para Volver a Encender EL CalentadorProcedimientos DE Servicio Limpieza DEL VentiladorSaque el ventilador del eje del motor Accesorios Procedimientos DEEspecificaciones Servicio TécnicoPiezas CON Garantía Diagramas DE CableadoPiezas DE Repuesto Piezas SIN GarantíaClasificación Ilustrada DE Piezas Lista DE Piezas Garantía Y Servicio DE Reparación Guarde Esta GarantíaModèles BLP375AT, SBLP375AT ET 375-F Table DES Matières LA SécuritéDéballage Information RelativeIdentification DU Produit Retirez toutes les pièces de lemballageThéorie DE Fonctionnement Alimentation EN PropaneVentilation Fonctionnement Pour Allumer Lappareil DE ChauffageVérifiez les fuites à chaque branchement Pour Arrêter Lappareil DE Chauffage EntreposageEntretien Pour Rallumer Lappareil DE ChauffageNettoyage DU Ventilateur Glissez le ventilateur pour le libérer de larbre moteurProcédures AccessoiresService Technique SpécificationsPièces Sous Garantie Diagrammes DE CâblagePièces DE Rechange Pièces QUI NE Sont PAS Sous GarantieVUE Détaillée DES Pièces Liste DES Pièces Service DE Garantie ET DE Réparation Conservez Cette Garantie

375-F, SBLP375AT specifications

Desa 375-F and SBLP375AT are innovative heating solutions designed to provide efficient and effective warmth in residential and commercial environments. These models stand out for their technological advancements, energy efficiency, and user-friendly features that cater to modern heating needs.

The Desa 375-F is primarily known for its powerful heating capabilities. It boasts a high efficiency rating, which means it can produce significant heat output while consuming less fuel. This efficiency not only translates to lower energy bills for users but also reduces the carbon footprint associated with heating. The unit is designed for easy installation and maintenance, making it an ideal choice for both new constructions and retrofits.

One of the standout features of the Desa 375-F is its adjustable thermostat, allowing users to set and maintain their desired temperature effortlessly. This feature contributes to comfort while also preserving energy, as the heating system can be programmed to operate only when needed. Additionally, the model incorporates a reliable safety shut-off mechanism that enhances user safety by preventing overheating.

On the other hand, the SBLP375AT model integrates advanced technologies that further enhance heating performance. It comes equipped with a state-of-the-art blower that ensures even heat distribution throughout the space. This feature minimizes cold spots and enhances overall comfort levels in the room. Moreover, the SBLP375AT is designed to be whisper-quiet during operation, making it a great option for bedrooms, offices, or any environment where noise may be a concern.

Both models incorporate high-quality materials and robust construction that ensure durability and long-lasting performance. Users can expect a longer lifespan from these units compared to traditional heating solutions, making them a worthwhile investment. Furthermore, the sleek design of both the Desa 375-F and SBLP375AT allows them to blend seamlessly with various interior styles, maintaining the aesthetic appeal of the space they occupy.

In conclusion, the Desa 375-F and SBLP375AT models exemplify the evolution of heating technology, combining efficiency, safety, and comfort. Whether for residential use or in professional settings, these heating solutions are designed to meet diverse needs while promoting energy conservation and environmental sustainability. Users can benefit from reliable warmth without sacrificing style or performance, making these models standout choices in the heating market.